Long Range Systems
20
T7450A User Manual
4. Press number 9 (selects a hidden menu). The screen shows:
5. Press F1 (Enable) or F4 (Disable) to set the feature on or off.
6. Go back to Setup and Press set Outbound Dialing OFF (see Dialing Properties, Page 11.)
7. Use the remote telephone to enter the paging data.
Remember Telephone Numbers
This allows your transmitter to retain the telephone numbers so they may be re-paged (Note: the unit will
only retain 100 numbers before it writes over the oldest numbers in the list).
1. Press SETUP.
2. Press F1 (more) until 3: Phone Settings is shown.
3. Select 3 (Phone settings).
4. Press 1 (General).
5. Press F1 (Program)
The screen shows 1. Access Number, 2. Direction, 3. Retention
6. Select 3 (Retention):
ON (F1) to retain the phone number after paging
OFF (F2) to discard the phone number after paging.
Dry Contact
The Dry Contacts (2 contacts located around the antenna) are a contact or switch that is connected through
a wire to the T7450A, for example: Door-Bell. This sensor can send a message to the pager an event hap-
pens (e.g., alarm if a door is opened). Default setting for the Contact Sensor is OFF. To program the Contact
Sensor (Dry Contact):
1. Press SETUP.
2. Press MORE (F1) until asked for an authorization code.
3. Type 5-6-7-8-9.
4. Select 1: Dry Contact.
5. Select 1: Prog Contacts.
6. Select Contact 1: OR 2:.
7. The Screen will show if Contact Sensor is currently on or off:
Inbound Dialing
Is ON-RING
Force always ON?
Enable
Disable
Phone Settings
1: General
2: DTMF Setup
MORE
HELP EXIT