First startup
ProtoMat S64/S104
38/54
LPKF Laser & Electronics AG | V. 1.0
5.2.5 The system's center of gravity
The following figure shows the center of gravity of the system:
Fig. 20: Center of gravity of the system
5.2.6 Connections provided by the customer
The following connections have to be available for the first startup:
Electrical data
Data
Value
Unit
Power supply
100/240
V
50/60
Hz
Nominal power
250
W
Stability
+/- 10
%
Pneumatic data
Data
Value
Unit
Pressure
min. 6
bar
Standard volume flow
40 l/min @ 6 bar
Nl/min
Compressed-air purity acc. to ISO 8573-1:2010-04
Data
Value
Unit
Solid particles
5
Class
Water
4
Class
Oil
4
Class