![LPKF S104 Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/lpkf/s104/s104_manual_1943482017.webp)
ProtoMat S64/S104
System description
V. 1.0 | LPKF Laser & Electronics AG
17/54
3.1 Technical data
General
Data
Value
Unit
IP Code (IEC 60529)
IP20
–
Service life
10
Years
Climatic conditions
Data
Value
Unit
Temperature range (operation)
20 to 25 (68 to 77)
°C (°F)
Temperature range (storage, transport)
-10 to 40 (14 to 104)
°C (°F)
Max. humidity, non-condensing
90
%
Electrical data
Data
Value
Unit
Power supply
100/240
V
50/60
Hz
Nominal power
250
W
Stability
+/- 10
%
Mechanical data
Data
Value
Unit
Dimensions (width x height x depth)
680 × 560 × 800
(~26.7 × 22 × 31.5)
mm
(in)
Weight (without packaging)
95 (~209.4)
kg (lbs)
Weight (with packaging)
135 (~297.6)
kg (lbs)
Load capacity
Data
Value
Unit
Min. distributed load
1.75
kN/m²
Min. point load on an area of 0.0007068 m²
0.0012
kN
Pneumatic data
Data
Value
Unit
Pressure
min. 6
bar
Standard volume flow
40 l/min @ 6 bar
Nl/min
Compressed-air purity acc. to ISO 8573-1:2010-04
Data
Value
Unit
Solid particles
5
Class
Water
4
Class
Oil
4
Class