Description
Backlit icon LCD.
3 status LEDs (power, ramp/run, fault).
Texts for measurements, settings and messages in 6 languages (ENG-ITA-FRA-ESP-POR-DEU).
Front-mounted keypad with 4 keys, for full parameter setting.
AUTOSET wizard for quick configuration in 4 steps of typical applications (pumps, fire fighting pumps, belt conveyors, mixers, fan, general purpose).
2-phase controlled starting, with integrated bypass relays.
4 different mechanical sizes and 11 electrical ratings for motors of 30 to 320A nominal.
Input voltage from 208 up to 600Vac.
Voltage or torque ramp starting, with current limitation.
Thermostatically controlled fan (optional for ADXL30…115), with dedicated diagnostics (fan disconnected or jammed).
3 programmable digital inputs, one of which is configurable for protection via the PTC sensor.
3 programmable relay digital outputs: one changeover, two NO.
Separate auxiliary supply.
Double power terminals.
Integrated electronic thermal protection, multi-class, separate for starting and running.
Complete set of motor protection: phase loss, no line, phase sequence, phase imbalance, rotor jammed, dry running (minimal torque), starting timeout, too high/low voltage.
Analogue temperature sensor to protect the thyristors, with display indication and alarm/pre-alarm thresholds.
Advanced self-diagnostics.
NFC interface for programming with smartdevice.
Front-mounted optical interface for programming and maintenance.
Isolated RS485 interface (optional, mounted in a dedicated slot) with Modbus protocol.
Alarms with language-specific messages and user-programmable properties.
Compatible with the
SAM1
App
,
NFC App
,
Synergy
supervision software and
Xpress
remote control and configuration software.
Optional accessories for DIN rail mounting (for ADXL 30…115).
Optional front panel remote display for controlling multiple starters (code EXCRDU1).
Front button functions
▲
▼
keys
–
Scroll through options. Press together to enter or quit a menu.
START key –
Confirms an option or increases the numerical value selected. If programmed to do so, enables motor starting with the front panel keypad.
STOP key –
Quits or decreases the numerical value selected. If programmed to do so, enables motor stopping with the front panel keypad.
Front LEDs
POWER LED (green) –
Auxiliary supply on.
RUN LED (green) –
Flashing: ramp in progress. Steady on: full voltage operation.
FAULT LED (red)
– Alarm on.
Display indications
Centrifugal pump
application
Fire
fighting
pump
application
Belt conveyor
application
Fan application
Mixer application
General purpose
application
Motor thermal status
bar
Thyristor thermal
status bar
Alarm in progress
Configuration in
progress
Communication in
progress
Graphical
accel./decel. ramp
Status and value