P0417 Удержание темп. клапана   (сек) 

0-900 

P0417 Valve preheating (sec) 

P0418 Температура подогрева  

OFF 

OFF/20-285 

P0418 Preheating temperature 

 

“05” МЕНЮ КОНТРОЛЯ ДВИГАТЕЛЯ 

По 

умолч. 

Пределы 

“05” ENGINE CONTROL 

 

 

 

 

Р0501 установка аналогового датчика давления масла  

OFF

 

(2) 

P0501 Pressure sensor selection 

Р0502 установка аналог. датч. температуры двигателя  

OFF

 

(2) 

P0502 Temperature sensor selection 

Р0503 установка аналог. датч. уровня топлива  

OFF

 

(2) 

P0503 Fuel sensor selection 

Р0504 предупреждающий сигнал низкого давления масла  

3.0 

0.1-180.0 

P0504 MIN pressure warning 

Р0505 аварийный сигнал низкого давлениям асла  

2.0 

0.1-180.0 

P0505 MIN pressure limit 

 
Р0506 предупреждающий сигнал высокой температуры 

90 

40-285 

P0506 MAX temperature warning 

Р0507 аварийный сигнал высокой температуры двигателя  

100 

40-285 

P0507 MAX temperature limit 

Р0508 предупреждающий сигнал уровня топлива (%)  

20 

0-100 

P0508 MIN fuel warning (%) 

Р0509 аварийный сигнал уровня топлива (%) 

10 

0-100 

P0509 MIN fuel level (%) 

Р0508 предупреждающий сигнал уровня топлива (%)  

1-30 

P0510 Alarms inhibition at starting (sec) 

Р0509 аварийный сигнал уровня топлива (%)  

110 

100-120 

P0511 MAX “W” speed limit  (%)  

(1)

 

Р0512 задержка сигн. максимального значения “w” датчика 

скорости (сек) 

0.5-20 

P0512 MAX “W” speed delay  (sec) 

Р0513 минимальный порог “w” датчика скорости (%)  

90 

80-100 

P0513 MIN “W” speed limit  (%)  

(1)

 

Р0514 задержка сигн. минимального значения “w” датчика 
скорости (сек) 

 

0-600 

P0514 MIN “W” speed delay  (sec)

 

Р0515 A03 задержка сигнала (мин) 

OFF 

OFF/1-60 

P0515 A03 Alarm delay (min) 

P0516 Порог минимальной температуры 

OFF 

OFF/20-285 

P0516 Low engine temperature 

(1)

   Скорость вращения определяется сигналом "W" или датчиком 

дополнительной карты RGK X21.

  

(2)

Перед установкой датчика, дополнительно проверьте необходимые 

характеристики указанные в программном обеспечении.

 

  (1)

   Engine speed detected by the "W" signal or the "pick-up” sensor of the 

RGK X21 optional board.

 

(2) 

Before setting the type of sensor, it is advisable to check the curve 
characteristic by means of the set-up software.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

“06” КОНТРОЛЬ СЕТИ (Только для RGK 60) 

По

 

у мо л ч

Пределы

 

“06” MAINS CONTROL (

Only for RGK 60) 

 

 

 

 

Р0601 минимальное пороговое значение напряжения сети 

(%) 

85 

70-100 

P0601 MIN voltage limit (%) 

Р0602 задержка сигнала минимума напряжения сети (сек) 

0-600 

P0602 MIN voltage delay (sec) 

Р0603 максимальное пороговое значение напряжения сети 

(%) 

115 

100-120 

P0603 MAX voltage limit (%) 

Р0604 задержка сигнала максимума напряжения сети (сек) 

0-600 

P0604 MAX voltage delay (sec) 

Р0605 время стабилизации параметров сети (сек) 

20 

1-600 

P0605 MAINS into limits delay(sec) 

Р0606 гистерезис пределов мин/макс (%) 

3.0 

0.0-5.0 

P0606 MIN/MAX hysteresis limit (%) 

Р0607 предельное значение асимметрии фаз (%) 

15 

5-20 

P0607 MAX asymmetry limit (%) 

Р0608 задержка сигнала асимметрии фаз (сек) 

0-600 

P0608 MAX asymmetry delay (s) 

Р0609 максимальное значение частоты (%) 

110 

100-120/OFF 

P0609 MAX frequency limit (%) 

Р0610 минимальное значение частоты (%) 

90 

OFF/80-100 

P0610 MIN frequency limit (%) 

Р0611 задержка сигнала мин/макс частоты (сек) 

0-600 

P0611 MIN/MAX frequency delay (sec) 

Р0612 контроль сети отключен/внутренний/внешний 

INT 

OFF/INT/EXT 

P0612 MAINS control OFF/internal/external) 

Р0613 контроль сети в режиме отключено (OFF/RESET) 

OFF 

OFF/ON/OFF+GLOB/

ON+GLOB 

P0613 MAINS control in RESET/OFF mode 

Р0614 контроль сети в ручном режиме (MAN) 

OFF 

OFF/ON/OFF+GLOB

/ON+GLOB 

P0614 MAINS control in MAN mode

 

     

  

 

Note!

 Контроль чередования фаз доступен через меню свойств сигнала. 

Это возможно когда напряжение > 50VAC. 

Контроль возможен также когда параметры P0613 и P0614 ВЫКЛ. 

ВНИМАНИЕ!  ТОЛЬКО ДЛЯ  RGK 60

Выходной контакт реле “контактор 

сети” закрыт когда  

питание снято с RGK 60 и контактор замкнут. 

 

Note!

 The phase sequence control can be enabled via the alarm properties 

menu. It is enabled only when the three phase voltages are > 50VAC. 

The control is enabled even when P0613 and P0614 are OFF. 

 

For RGK 60 only 
CAUTION!

   The “mains contactor control” output relay is NC so when power

 

is removed from the RGK 60 the mains contactor is closed. 

 

 

Содержание RGK 50

Страница 1: ...a of the selected data page or to modify the parameters OFF RESET MAN AUT and TEST keys Press these keys to select the operating mode The illuminated LED indicates the selected operating mode if it is...

Страница 2: ...le within preset limits When the LED of the changeover symbol is on the actual closing of switching devices has occurred when flashing there is an incorrect feedback signal for the actual closing or o...

Страница 3: ...is immediately stopped if running by changing to this operating mode and any eventual alarms are reset If the cause of the alarm is still present it cannot be reset MAN mode The engine can be manuall...

Страница 4: ...release the OFF RESET key User s menu Access to parameters setting limited to those the final user needs To enter the menu press the OFF RESET key for 5 seconds then release it Commands menu Access t...

Страница 5: ...n to the screen page with data alarms measurements etc This page can contain details convenient to the user such as customer s name date of panel or genset manufacture set up file name serial number o...

Страница 6: ...ing To set the engine hour counter press the OFF RESET key and subsequently the ENTER and keys for 5s after that release them Set the counter using the or key and press the EXIT key to store and exit...

Страница 7: ...nected sec P0215 OFF OFF 1 30000 P0215 Fuel tank capacity P0216 LL LL LN LL N P0216 Voltage control P0217 1 0 600 P0217 Motorised circuit breaker opening sec P0218 1 0 600 P0218 Motorised circuit brea...

Страница 8: ...ble to check the curve characteristic by means of the set up software 06 RGK 60 06 MAINS CONTROL Only for RGK 60 0601 85 70 100 P0601 MIN voltage limit 0602 5 0 600 P0602 MIN voltage delay sec 0603 11...

Страница 9: ...by means of the set up software Caution The external CT must be chosen on the basis of the maximum current defined by the parameters P0802 and P0804 09 TEST AND MAINTENANCE 09 TEST AND MAINTENANCE 09...

Страница 10: ...GK 60 25min 0 99 P1113 Start engine delay RGK 60 only EJP 1114 RGK 60 5min 0 30 P1114 Changeover delay RGK 60 only 1115 RGK 60 OFF OFF ON P1115 Changeover block RGK 60 only P1116 OFF OFF 1 600 P1116 D...

Страница 11: ...Disabled 1 P1207 Input terminal 8 7 8 7 NO NO NC 8 7 Type of contact 8 7 0 0 0 0 6000 0 8 7 Closing delay s 8 7 0 0 0 0 6000 0 8 7 Opening delay s P1208 8 8 Disabled 1 P1208 Input terminal 8 8 8 8 NO...

Страница 12: ...lobal alarm 1 P1301 Output terminal 5 3 5 4 5 5 Function 5 3 Relay 1302 6 2 Siren 1 P1302 Output terminal 6 2 Function 6 2 Relay 1303 6 3 Decelerator 1 P1303 Output terminal 6 3 Function 6 3 Relay 130...

Страница 13: ...g RGK 60 only RGK 60 Mains motorised circuit breaker closing RGK 60 only Generator motorised circuit breaker opening Generator motorised circuit breaker closing Valve preheating 1 Relay 1 set reset vi...

Страница 14: ...inputs N B 1 See the list of the available functions in the Programmable inputs table N B Refer to the setting mode of standardinputs for the property of these inputs 15 15 PROGRAMMABLE OUTPUTS EXPANS...

Страница 15: ...efficient battery A17 X X X X X X X A1 7 Charger alternator failure A18 X X X X X A1 8 W signal failure 1 A19 W X X X X X A1 9 Low engine W speed 1 A20 W X X X X X X A2 0 High engine W speed 1 A21 X X...

Страница 16: ...erature analog sensor A47 A47 Battery charger alarm UA1 1 UA1 User s alarm 1 UA2 2 UA2 User s alarm 2 UA3 3 UA3 User s alarm 3 UA4 4 UA4 User s alarm 4 UA5 5 UA5 User s alarm 5 UA6 6 UA6 User s alarm...

Страница 17: ...age A15 A1 5 Low battery voltage A16 A1 6 Inefficient battery A17 A1 7 Charger alternator failure A18 A1 8 W signal failure 1 A19 W A1 9 Low engine W speed 1 A20 W A2 0 High engine W speed 1 A21 A2 1...

Страница 18: ...1 UA1 User s alarm 1 UA2 2 UA2 User s alarm 2 UA3 3 UA3 User s alarm 3 UA4 4 UA4 User s alarm 4 UA5 5 UA5 User s alarm 5 UA6 6 UA6 User s alarm 6 UA7 7 UA7 User s alarm 7 UA8 8 UA8 User s alarm 8 1 W...

Страница 19: ...ENERATORE CONTATTORE RETE 2 4 4 1 4 3 4 2 TA2 TA1 3 1 3 2 3 3 3 4 INGRESSI CT1 CORRENTE CT2 CURRENT INPUTS LIBERO FREE FREE FREE GENERATOR OVERLOAD GENERATOR CONTACTOR MAINS CONTACTOR REMOTE START FRE...

Страница 20: ...0 4 10 2 1 3 L1 1 1 1 2 RETE TENSIONE 2 1 1 4 N L1 2 2 2 3 GENERATORE TENSIONE 6 2 6 4 6 5 6 3 6 1 5 1 5 3 5 2 4 4 CONT GENERATORE CONTATTORE RETE 2 4 4 1 4 3 4 2 TA1 3 1 3 2 3 4 3 3 INGRESSO CORRENTE...

Страница 21: ...APRISA ALTERNATORI TIPO ELETTROVALVOLA CARBURANTE DUCATI SAPRISA ALTERNATOR TYPE BATTERY W SPEED INPUT FUEL SOLENOID VALVE BATTERIA DECELERATOR SIREN START 6 5 B 10 4 7 2 7 1 6 6 10 2 10 3 10 1 SIRENA...

Страница 22: ...typical 2 9V 5 3V t 4 3V Input high voltage 5 3V typical 4 3V 50ms Input delay 50ms W Speed input W AC Input type AC coupling 5 50Vpp Voltage range 5 50Vpp 40 2000Hz Frequency range 40 2000Hz 500rpm E...

Страница 23: ...A 12VDC 130mA 24VDC 4 1 4 2 4 3 4 4 Relay output 4 1 4 2 4 3 4 4 terminals voltage free 1 1 RGK 60 Contact type 1 NC for mains for RGK 60 only And 1 NO for generator UL B300 30VDC 1A UL Rating B300 30...

Страница 24: ...0k L N 1 2 3 Wiring mode 1 2 or 3 phases with or without neutral Current inputs Ie 5A Rated current Ie 5A 0 02 6A Measuring range 0 02 6A UL Max 5 A UL rating Supplied by an external current transform...

Страница 25: ...EN 60068 2 6 LROS Lloyd s Register Of Shipping IEC EN 60068 2 52 RINA Italian Naval Register UL 508 and CSA C22 2_N14 95 cULus IEC EN 61010 1 IEC EN 55011 EN 50082 2 IEC EN 60028 2 61 IEC EN 60068 2...

Отзывы: