background image

Lorenz Messtechnik GmbH 

Obere Schlossstrasse 127/129/131

73553 Alfdorf 

 

Phone +49 7172 93730-0, Fax +49 7172 93730-22

[email protected]

www.lorenz-messtechnik.de

Technical changes, errors and misprints excepted.

090325c_SI-RS485

3/13

1  Imprint / Copyright

 

© 2019 Lorenz Messtechnik GmbH, D-73553 Alfdorf

 

These operating instructions do not constitute an agreed quality agreement or durability guarantee 

 

within the meaning of § 443 BGB (German Civil Code).

 

Technical changes, errors and misprints excepted.

 

No part of this publication may be reprinted without the written permission of Lorenz Messtechnik 

 

GmbH, Alfdorf.

2  Important Notes / Keeping

 

Before installing and commissioning the device, these operating instructions, and in particular the  

 

corresponding safety instructions, must be read. The device may only be used as described in this 

 

manual to prevent injury or damage. 

 

The operating instructions have been drawn up in accordance with EN 82079-1 and must be kept in  

 

a safe place.

 

2.1  General Informations

 

These operating instructions are intended for technically qualified personnel who have appropriate 

 

 

knowledge in the field of measurement and control technology. Qualified personnel are persons who 

 

 

are familiar with the installation, operation, maintenance and repair of the device and have the appro- 

 

priate qualifications. The personnel must have knowledge of the legal and safety regulations and be 

 

 

able to apply them.

 

The device may only be used by qualified personnel in accordance with the technical data in connec-

 

 

tion with the safety regulations and rules set out below. During operation, the legal and safety regula- 

 

tions required for the respective application must also be observed. This also applies analogously to  

 

the use of accessories.

 

The exact information about all safety instructions and warnings contained in these operating in- 

 

structions as well as their correct technical implementation are prerequisites for the safe installation,  

 

commissioning, safe operation and maintenance of Lorenz Messtechnik GmbH devices. All measures  

 

must only be carried out by qualified personnel. All persons involved in the project planning, instal-

 

 

lation and operation of Lorenz Messtechnik GmbH devices must be familiar with the safety concepts  

 

in the automation technology and be qualified in the above-mentioned sense.

 

For reasons of clarity, these operating instructions cannot cover all details and information and not all 

 

applications for the handling of devices from Lorenz Messtechnik GmbH. Nor can all conceivable  

 

types of installation, operation and maintenance must be taken into account.

Содержание SI-RS485

Страница 1: ...73553 Alfdorf Phone 49 7172 93730 0 Fax 49 7172 93730 22 info lorenz messtechnik de www lorenz messtechnik de Technical changes errors and misprints excepted 090325c_SI RS485 1 13 Amplifiers Operatin...

Страница 2: ...ect Use 7 5 Technical Details 7 5 1 Configuration of the Connections 7 5 2 Adjustment of the Second Order Low Pass Filter for each Sensor Channel 7 5 2 1 Changing via VS3 7 5 2 2 Changing via LCV USB...

Страница 3: ...who are familiar with the installation operation maintenance and repair of the device and have the appro priate qualifications The personnel must have knowledge of the legal and safety regulations and...

Страница 4: ...must be ensured that a the device its malfunction or its failure does not lead to damage to property or a loss of that can lead to danger to people It is also important to prevent the precautions that...

Страница 5: ...the operating instructions and in particular the safety instructions Incorrect use e g by untrained personnel may result in residual hazards The operating instructions must be read and understood by a...

Страница 6: ...ation excludes any liability on our part for damages resulting there from Repairs and modifications are prohibited 3 4 CE Marking With the CE marking Lorenz Messtechnik GmbH guarantees that its produc...

Страница 7: ...value tare value minimal value and maximal value Presentation of the measured data in a diagram Storage of measured data in CSV format output configurable Storage of the diagram in BMP format output s...

Страница 8: ...rther information regarding programming with own software we refer to document 090110 Lorenzprotocol A flexible command set for digital sensors and interfaces 6 Pin Assignments 6 1 Pin Assignment for...

Страница 9: ...lti component sensor M 2354 is directly connec ted to the SI RS485 DMS DMS with both outputs The system allows simultaneous recording of force torque courses which chronologically refer to each other...

Страница 10: ...ch other 8 Debugging This chart helps to find frequent errors and the measures for debugging Error Possible Cause Debugging A connection to the SI RS485 is not possible Power supply not connected Conn...

Страница 11: ...0 mA Measured values 30000 digits 25000 digits 30000 digits 0 20000 digits 25000 digits 25000 digits 0 20000 digits 25000 digits 0 20000 digits Resolution 1 mV V 10000 digits 1V 2500 digits 1 mV V 100...

Страница 12: ...nditions of Delivery and Sale at www lorenz messtechnik de Article No Description Type 115134 Adjustment amplifier with simulator mV V 10V 0 4 20 mA 113591 Input range 4 5 mV V per channel LCV USB3 SI...

Страница 13: ...changes errors and misprints excepted 090325c_SI RS485 13 13 11 Reference Information Document number 090324 operation manual German Document number 080997 data sheet German 080996 Document number 090...

Отзывы: