7.2 Displacement Sensor Potentiometric (supplied from the SI-RS485)
A
SI-RS485
with
minimum
U5-input
is
suitable.
The
accuracy
of
the
displacement
measurement
is depending on the quality of the reference vol-
tage.
With
this
set-up,
arbitrary
measuring
variables,
depending
on
displacement
measurements,
can
be
recorded
and
referred
to
each
other.
8 Debugging
This chart helps to find frequent errors and the measures for debugging.
Error
Possible Cause
Debugging
A connection to the SI-RS485
is not possible
Power supply not connected • Connect power supply
Supply voltage is shortened • Fix the short circuit
Output signal is at the upper
or lower modulation limit
Active sensor is connected
to the strain gauge input
• Check on type label for which in-
put type has been configured for
the applied sensor connection
Supply voltage connected to
sensor input
• Check/correct the pin assign-
ment
Output signal fluctuates
(strain gauge)
Open sensor input
• Connect sensor
Cut-off frequency adjust
-
ment not correctly set
•
Set the right cut-off frequency
0V / GND
R >
10
0
5V reference
controller
12V
Output 0 ... 25000 Digits