Lorenz Messtechnik GmbH
Obere Schlossstrasse 127/129/131
73553 Alfdorf
Phone +49 7172 93730-0, Fax +49 7172 93730-22
Technical changes, errors and misprints excepted.
090325c_SI-RS485
9/13
6.3 Pin Assignment for Active Current Sensors with mA Signal
6.4 Connection Assignment for the RS485-Interface
7
Other Application Examples
7.1 Multi-Component Sensor M-2354 Force and Torque
(strain gauge / strain gauge)
The
multi-component
sensor
M-2354
is
directly
connec-
ted
to
the
SI-RS485/DMS/DMS
with
both
outputs.
The
system
allows
simultaneous
recording
of
force-torque-
courses
which
chronologically
refer
to
each
other.
Description
Pin (12 pin socket)
Remark
0V / GND
E
Ground reference for 12V supply
12V
F
Supply for 12V active sensors
C
Signal input
Signal -
D
Relating to signal input (internally 0V / GD)
Control signal
K
If available in sensor
Shield
M
Do not connect shield with sensor housing
Description
Pin (12 pole socket)
Remark
0V / GND
E
Ground reference for 5V and 12V supply
RS485 (A)
L
Signal RS485
RS485 (B)
J
Signal RS485
Shield
M