9  Technical Data

 

1

 Mains adapter included in scope of delivery at first order

RS485-Sensor-Interface SI-RS485

Type

SI-RS485/DMS/

DMS

SI-RS485/U5/U5 SI-RS485/U10/

U10

SI-RS485/I20/I20 SI-RS485/DMS/

U5

Article-No.

113261

113262

113263

113264

113265

Input range

2 x ±3 mV/V

2 x ±5V

2 x ±10V

2 x 0/4 ... 20 mA

±3 mV/V; ±5V

Measured values

±30000 digits

±25000 digits

±25000 digits

0 ... 20000 digits

±30000 digits; 

±25000 digits

Resolution

1 mV/V 

 10000 

digits

1V 

 5000 digits 1V 

 2500 digits

1 mA 

 1000 

digits

1 mV/V 

 10000 

digits;

1V 

 5000 digits

Type

SI-RS485/DMS/U10 SI-RS485/DMS/

I20

SI-RS485/U5/U10 SI-RS485/U5/I20 SI-RS485/U10/I20

Article-No.

113266

113267

113268

113269

113270

Input range

±3 mV/V; ±10V

±3 mV/V;

0/4 ... 20 mA

±5V; ±10V

±5V; 0/4 ... 20 mA ±10V; 0/4 ... 20 

mA

Measured values

±30000 digits; 

±25000 digits

±30000 digits;

0 ... 20000 digits

±25000 digits

±25000 digits;

0 ... 20000 digits

±25000 digits;

0 ... 20000 digits

Resolution

1 mV/V 

 10000

digits;

1V 

 2500 digits

1 mV/V 

 10000 

digits;

1 mA 

 1000 

digits

1V 

 5000 digits; 

1V 

 2500 digits

1V 

 5000 digits;

1 mA 

 1000 

digits

1V 

 2500 digits;

1 mA 

 1000 

digits

Evaluation Side

Zero point

0 digits

Output format

16 bit signed int.

Input resistance

>1 MΩ (only for DMS/U5/U10)

Rated burden

62 Ω (only for I20)

Second-order low-pass filter

30/300/1000/3000 Hz

Measuring rate

max. 2500 meas./s

Temperature drift

4 bit/10 K

Linearity error

±32 digits

Accuracy

±32 digits

Supply voltage of

mains adapter

1

100 ... 240VAC

Output mains adapter

24VDC, 1.25 A

Supply voltage SI-RS485

12 ... 30VDC ≤600 mA

Sensor Side

Sensor supply

Strain gauges (DMS): 5V ≤20 mA

U5/U10/I20: 12V ≤200 mA

Cable length

SI-RS485 - Sensor

1 m (max. 3 m)

Miscellaneous

Electrical connection

Strain gauges (DMS): Female socket 6-pin

U5/U10/I20: Female socket 12-pin

RS485: Male socket 12-pin

Rated temperature range

10 ... 40 °C

Operating temperature range

0 ... 50 °C

Storage temperature range

-10 ... 70 °C

Dimension (L x W x H)

125 x 80 x 57 mm

Level of protection

IP40

Weight

0.5 kg

Содержание SI-RS485

Страница 1: ...73553 Alfdorf Phone 49 7172 93730 0 Fax 49 7172 93730 22 info lorenz messtechnik de www lorenz messtechnik de Technical changes errors and misprints excepted 090325c_SI RS485 1 13 Amplifiers Operatin...

Страница 2: ...ect Use 7 5 Technical Details 7 5 1 Configuration of the Connections 7 5 2 Adjustment of the Second Order Low Pass Filter for each Sensor Channel 7 5 2 1 Changing via VS3 7 5 2 2 Changing via LCV USB...

Страница 3: ...who are familiar with the installation operation maintenance and repair of the device and have the appro priate qualifications The personnel must have knowledge of the legal and safety regulations and...

Страница 4: ...must be ensured that a the device its malfunction or its failure does not lead to damage to property or a loss of that can lead to danger to people It is also important to prevent the precautions that...

Страница 5: ...the operating instructions and in particular the safety instructions Incorrect use e g by untrained personnel may result in residual hazards The operating instructions must be read and understood by a...

Страница 6: ...ation excludes any liability on our part for damages resulting there from Repairs and modifications are prohibited 3 4 CE Marking With the CE marking Lorenz Messtechnik GmbH guarantees that its produc...

Страница 7: ...value tare value minimal value and maximal value Presentation of the measured data in a diagram Storage of measured data in CSV format output configurable Storage of the diagram in BMP format output s...

Страница 8: ...rther information regarding programming with own software we refer to document 090110 Lorenzprotocol A flexible command set for digital sensors and interfaces 6 Pin Assignments 6 1 Pin Assignment for...

Страница 9: ...lti component sensor M 2354 is directly connec ted to the SI RS485 DMS DMS with both outputs The system allows simultaneous recording of force torque courses which chronologically refer to each other...

Страница 10: ...ch other 8 Debugging This chart helps to find frequent errors and the measures for debugging Error Possible Cause Debugging A connection to the SI RS485 is not possible Power supply not connected Conn...

Страница 11: ...0 mA Measured values 30000 digits 25000 digits 30000 digits 0 20000 digits 25000 digits 25000 digits 0 20000 digits 25000 digits 0 20000 digits Resolution 1 mV V 10000 digits 1V 2500 digits 1 mV V 100...

Страница 12: ...nditions of Delivery and Sale at www lorenz messtechnik de Article No Description Type 115134 Adjustment amplifier with simulator mV V 10V 0 4 20 mA 113591 Input range 4 5 mV V per channel LCV USB3 SI...

Страница 13: ...changes errors and misprints excepted 090325c_SI RS485 13 13 11 Reference Information Document number 090324 operation manual German Document number 080997 data sheet German 080996 Document number 090...

Отзывы: