![Lorentz PS1200 Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/lorentz/ps1200/ps1200_instructions-for-installation-operation-service_1939703030.webp)
30
6
PREPARING TO INSTALL THE PUMP
6.1
WARNINGS about Handling Helical Rotor Pumps
CAUTION (helical rotor mod-
els) BEFORE INSTALLATION,
KEEP THE PUMP OUT OF THE
SUN.
If the pump gets hot, the
rubber stator will expand and
may lock the rotor. No damage will result from
this, but you may be unable to test the
direction of rotation. If the pump gets hot,
allow it to cool in water for 20 minutes before
testing.
WARNING (helical rotor mod-
els) DO NOT APPLY MACHINE
GREASE TO THE PUMP.
Ordinary machine grease will
damage the stator (NBR
rubber) and void the warranty.
Helical rotor
pumps are lubricated at the factory with a
clear, non-toxic grease. Its only purpose is
temporary, to allow the pump to be run dry for
a short time to test the direction of rotation.
There is no normal reason to reapply lubricant
but if you do, use
VASELINE
(petroleum jelly,
white petrolatum) or non-toxic silicone grease
approved for water valves and seals.
WARNING for SIPHON APPLI-
CATIONS
If a pump system has
a vertical lift LESS THAN 33
FEET (10m) up from the surface
of the water source, and then the
water flows downhill to a lower
point, a siphon effect may cause suction on
the pump. This will cause an upward thrust on
the motor shaft, resulting in damage to the
motor. Prevent this by installing an air vent or
a vacuum breaker at the high point on the
pipe.