3DM-GX5-45
™
GNSS-Aided Inertial Navigation System
DCP Manual
4.2.4
Get IMU Data Base Rate (0x0C, 0x06)
Description
Get the base rate for the IMU data in Hz.
Returns the value used for data rate calculations. See the
com-
mand.
Field Format
Field Length
Field
Descriptor
Field Data
Command
0x02
0x06
None
Reply Field 1:
ACK/ NACK
0x04
0xF1
U8 - echo the command byte
U8 - error code (0: ACK, non-zero: NACK)
Reply Field 2:
IMU Base Rate
0x04
0x83
U16 – IMU data base rate (Hz)
Example
MIP Packet Header
Command/Reply Fields
Checksum
Sync1
Sync2
Desc.
Set
Payload
Length
Field
Length
Field
Desc.
Field Data
MSB
LSB
Command: Get
IMU Base Rate
0x75
0x65
0x0C
0x02
0x02
0x06
0xF0
0xF7
Reply Field 1:
ACK/NACK
0x75
0x65
0x0C
0x08
0x04
0xF1
Command echo: 0x06
Error code: 0x00
Reply Field 2:
IMU Base Rate
0x04
0x83
Base rate (Hz):
0x0x0064
0xD4
0x6B
Copy-Paste version of the command: “7565 0C02 0206 F0F7”
48