4.3.35
Magnetometer Capture Auto Calibration (0x0D, 0x27)
Description
This command captures the current value of the auto-calibration, applies it to the current
fixed hard and soft iron calibration coefficients, and replaces the current fixed hard and
soft iron calibration coefficients with the new values.
This may be used in place of (or in addition to) a manual hard and soft iron calibration utility
such as
MIP Iron Calibration
. This command also resets the auto-calibration coefficients.
Function selector values:
0x01 – Capture and use new settings
0x03 – Save current settings as startup settings
1
Notes
1.This is the same as issuing the 0x0C, 0x3A and 0x0C, 0x3B commands with the “0x03 –
Save current settings as startup settings” function selector.
Field Format
Field Length
Field
Descriptor
Field Data
Command
0x27
0x27
U8 - Function Selector
Reply Field:
ACK/ NACK
0x04
0xF1
U8 - Echo the command descriptor
U8 - Error code (0: ACK, non-zero: NACK)
Example
MIP Packet Header
Command/Reply Fields
Checksum
Sync1
Sync2
Desc.
Set
Payload
Length
Field
Length
Field
Desc.
Field Data
MSB
LSB
Command
0x75
0x65
0x0D
0x02
0x02
0x27
Selector: 01
0x15
0x36
Reply Field:
ACK/NACK
0x75
0x65
0x0D
0x04
0x04
0xF1
Echo cmd: 0x27
Error code: 0x00
0x95
0xA8
Copy-Paste version of the command: "7565 0D03 0327 0115 36”