Chapter 2 Loop-IP6610 Installation
7
2.2.1.2 Power
The power connection on your unit will be either AC 100-240V or DC 20-60V. An optional DC 36-75V power
connection is also available. Before attaching any power supply, check the label on the rear of the Loop-IP
6610 unit to ensure that you connect the unit to the correct power source. The power switch at the rear of
the unit should be in the OFF position while you connect the power source. See Section 2.5, Rear Panel
Connectors and Switch.
Caution:
Do not
(under any circumstances) connect the Loop-IP unit to a power source that
is inconsistent with the power rating that is labeled on the rear of the Loop device.
2.2.1.3 Line Connections
You can now make your line and Ethernet connections.
Step 1 Connect the Loop-IP 6610 to a LAN
Connect the LAN to the 10/100 Ethernet port of the IP 6610. Because the Loop-IP 6610 supports MDI/MDI-
X auto crossover, you can use either a parallel or a crossover cable to make the connection.
Step 2 Connect the E1/DS1 Line to the Loop-IP 6610
If you are using a RJ48 (E1/DS1) line connector, plug it into the IP 6610’s RJ 48 receptacle. If you are
using BNC (E1)connectors, plug them in. The BNC receptacles on the IP 6610 are clearly labeled RX-IN
and TX-OUT.