Running Interface
Turn on the pump, the pump is initialized first, then display the running inter face.
a.
3
4
7.
000 mL/min
50.0
INT
g.
f.
b.
c.
d.
h.
c.
d.
=
Single Channel
0.7- 42
Single Channel
2.7-162
Single Channel
5.1-306
Single Channel
8.2-492
Single Channel
17-1020
Single Channel
29-1740
Single Channel
38-2280
Single Channel
17-1020
Single Channel
29-1740
Single Channel
17-1020
Single Channel
29-1740
Single Channel
38-2280
Single Channel
50-3000
30-1800
58-3500
83-5000
100-6000
29-1740
8.2-492
20-1150
30-1800
4.2-150
23-800
42-1500
68-2400
84-2950
120-4170
(
1,2)×
YZ1515x
(1,2)
×YZ
Ⅱ
15
(1,2)×YZ
2
515x
(1,2)×
YZ
Ⅱ
25
KZ25
BZ25
DG15-24
DMD25
#
15
#
24
#
15
#
24
#
35
#
36
#
15
#
24
#
35
#
36
#
24
#
16
#
25
#
17
#
119
#
120
#
15
#
24
#
35
#
36
#
13
#
14
#
19
#
16
#
25
#
17
#
18
The running speed range of DMD25 is less than 350 rpm.
Pump heads and tubing can be selected referring to above table. It is necessary to select
suitable pump heads and tubing to get higher flow rates and dispensing accuracy. We
suggest the needed flow rates are in the 20% to 80% of ref. flow rates range.
Flow Rate Display
Dispensing display: Dispensing parameters are displayed in two inter faces,
Press
Exit Key
to switch these two inter faces.
a.
Current flow rates: Display current flow rates. Turn the
Knob
to increase or
decrease the flow rates.
b.
Current speed: Display current speed. The speed will change when adjusting
the flow rates.
c.
Running direction: Indicate the direction of the pump. Means clockwise and
Means counter clockwise.
d.
Running status:
means the pump is running;
means the pump stops;
Means pump pauses. Press
Start/Stop Key
to control the running state of
the pump.
e.
Control mode: INT means the pump is controlled internally; V means the pump
is controlled by external analog voltage signal; mA means the pump is
controlled by external analog current signal; Hz means the pump is controlled
by external 0 -10 KHz pulse signal. Off means shutting off the external control
function by setting menu;
f.
Dispensing volume: Display dispensing volume in dispensing mode.
g.
Copy number: Display copy number under dispensing mode.
h.
Dispensing time: Display the dispensing time. When the dispensing procedure
star ts, the dispensing time will be counted down. Adjust the flow rates to
change the dispensing time in dispensing parameters setting inter face.
Vol
:
13.0 mL
Copy
:
9999
Disp T.
:
79.0"
100 RPM
Acceptable Pump Heads and Tubing (Table 1)
Pump Heads
Ref. Flow Rates
(mL/min)
Tubing
(mm)
WT600-1F OPERATING MANUAL
WT600-1F OPERATING MANUAL