Running Interface

Turn on the pump, the pump is initialized first, then display the running inter face.

 

a.

3

4

7.

000 mL/min

50.0

INT

g.

 

f.

b.
c.

d.

 

h.

c.

d.

 

=

Single Channel

 0.7- 42

Single Channel

 2.7-162

Single Channel

 5.1-306

Single Channel

 8.2-492

Single Channel

 17-1020

Single Channel

 29-1740

Single Channel

 38-2280

Single Channel

 17-1020

Single Channel

 29-1740

Single Channel

 

17-1020

Single Channel

 

29-1740

Single Channel

 

38-2280

Single Channel

 

50-3000

30-1800

58-3500

83-5000

100-6000

29-1740

8.2-492

20-1150

30-1800

4.2-150

23-800

42-1500
68-2400
84-2950

120-4170

(

1,2)×

YZ1515x

(1,2)

×YZ

15

(1,2)×YZ

2

515x

(1,2)× 

YZ

25

KZ25

BZ25

DG15-24

DMD25

#  

15  

#

24

#

15

#

24

#

35

  

#

36

#

15

#

24

#

35

  

#

36

#

24

#

16

#

25

#

17

#

119

#

120

#

15

#

24

#

35

#

36

#

13

#

14

#

19

#

16

#

25

#

17

#

18

The running speed range of DMD25 is less than 350 rpm.

Pump heads and tubing can be selected referring to above table. It is necessary to select 
suitable pump heads and tubing to get higher flow rates and dispensing accuracy. We 
suggest the needed flow rates are in the 20% to 80% of ref. flow rates range.

Flow Rate Display

Dispensing display: Dispensing parameters are displayed in two inter faces, 
Press 

Exit Key

 to switch these two inter faces.

a. 

 

 Current flow rates: Display current flow rates. Turn the 

Knob

 to increase or 

decrease the flow rates. 

b.  

 

Current speed: Display current speed. The speed will change when adjusting 
the flow rates.

c.  

 

Running direction: Indicate the direction of the pump.        Means clockwise and    

              Means counter clockwise.

d.  

 

Running status:  

   

 means the pump is running; 

    

means the pump stops;  

            Means pump pauses. Press 

Start/Stop Key

 to control the running state of 

the pump.

e.  

 

Control mode: INT means the pump is controlled internally; V means the pump 
is controlled by external analog voltage signal; mA means the pump is 
controlled by external analog current signal; Hz means the pump is controlled 
by external 0 -10 KHz pulse signal. Off means shutting off the external control 
function by setting menu;

f.  

  

Dispensing volume: Display dispensing volume in dispensing mode.

g.  

 

Copy number: Display copy number under dispensing mode.

h.  

 

Dispensing time: Display the dispensing time. When the dispensing procedure 
star ts, the dispensing time will be counted down. Adjust the flow rates to 
change the dispensing time in dispensing parameters setting inter face.

Vol

:  

13.0 mL

Copy

: 

9999

Disp  T.

: 

79.0"

100  RPM

Acceptable Pump Heads and Tubing (Table 1)

Pump Heads 

Ref. Flow Rates

(mL/min)

Tubing  

(mm)

WT600-1F OPERATING MANUAL

WT600-1F OPERATING MANUAL

Содержание WT600-1F

Страница 1: ...WT600 1F Peristaltic Pump Baoding Longer Precision Pump Co Ltd WT600 1F PERISTALTIC PUMP OPERATING MANUAL...

Страница 2: ...ds to be maintained or repaired Please shut down the power supply before install the external control equipments WT600 1F OPERATING MANUAL Table of Contents Instruction Operation Panel Basic Operation...

Страница 3: ...Direction Key Prime Key Knob LCD Display Power Switch Basic Operation Start Stop Key Press the Start Stop Key to start or stop the pump Direction Key Press the Direction Key to change the rotation dir...

Страница 4: ...t Key to switch these two interfaces a Current flow rates Display current flow rates Turn the Knob to increase or decrease the flow rates b Current speed Display current speed The speed will change wh...

Страница 5: ...2 Control Mode 2 Ext Cont ON 3 Address 1 System Setting All the setting can not be done when pump is running Pump head and tubing setting Press the Knob to highlight Pump Head Tube line press Knob ag...

Страница 6: ...previous menu Flowrate Dispensing Disp Vol 2 02mL Copy No 10 Disp Vol 2 02 mL Copy No 10 1 System Setting 2 Control Mode 1 System Setting 2 Control Mode 3 Disp Setting 4 Calibration 1 System Setting 2...

Страница 7: ...ob to select test time its range is from 30 to 1800 seconds press Knob for confirmation Press Exit Key to return to previous menu Press Start Stop Key the LCD displays running time and actual volume R...

Страница 8: ...nd tubing refer to the table of page 4 Press Knob to enter System Setting interface to set pump head and tubing Set Back Suction rpm Enter control mode interface to select Dispensing Enter Dispense Se...

Страница 9: ...ns Definition External Control Output External Control Output Port Pin Diagram DB9 Footswitch Function Connect Footswitch to r control Input Port to control Start Stop of pump emote It can be set acco...

Страница 10: ...15X YZ2515X YZII15 YZII25 DG15 24 KZ25 BZ25 DMD25 Operation Mode Membrane keypad and Knob Direction Control CW and CCW reversible Prime Full speed for fast filling and emptying Back Suction Prevent th...

Отзывы: