COOLING SYSTEM
Cooling liquid features
It is recommended to use cooling liquids according to the recommended percentages, because besides lowering the freezing
point as well as the pressure determined by the plug (radiator or expansion vessel), it determines the rise of the liquid boiling
point inside the circuit.
Furthermore, it protects the whole circuit from corrosion, deposits, and cavitations can also be easily avoided.
In case radiators with aluminium cores are used, it is strictly necessary to use a solution of 50% H
2
O and 50% glycol
solution.
It's mandatory the use for the cooling system of the correct percentage of mixture water and glycole.
The lack to the above prescription will result in warranty avoidance
PLUG SETTING
WATER
SOLUTION WITH 30 % ÷ 50 % GLYCOL
0,50 bar
98° C
102° ÷ 105° C
0,70 bar
102° C
107° ÷ 110° C
0,90 bar
105° C
110° ÷ 112° C
1,00 bar
106° C
112° ÷ 114° C
Thermostatic valve features
- Opening starting point 80° C ± 2° C
- Max opening 95° C with 7 mm stroke
WATER COOLED SYSTEM DESCRIPTION
The engine cooling is carried out by means of liquid (50% of water and 50% of glicole) by the centrifugal pump, driven
by the timing belt.
Until the temperature of the liquid is 84-87 °C, the water is recirculated through a by-pass circuit. After, the thermostat
valve provided on the cylinder head allows the recirculation and the cooling through the radiator.