Product Description and Environment
Module 5092
3-3
The control board can also be fitted with an optional reports package supporting
an on board real time clock and date function together with a range of standard
reports and logs as shown in the equipment user manuals.
The control unit is compatible with the following Loma communication packages.
LomaNet - Optional node, serial link board, reports and logs package and
external connectors required.
LomaLink - Optional serial link board, reports and logs package and external
connectors required.
Electrical Supplies
Electrical supplies are connected to the control unit directly into the bottom of
the control unit via waterproof glands.
Control unit connection details can be found in the -
on page 12
in the “Maintenance” section of this manual.
For specific wiring connection information including any conveyor wiring
diagrams, please refer to the “Wiring Diagrams” package in your Customised
User Manual.
Spurious Triggering
The Loma range of Metal Detectors is the product of many years' experience
and development. They are inherently reliable. Provided a detector is set up as
described in the setting up procedure, it is unlikely that any problem lies within
the head assembly or control unit.
Sources of spurious or false triggering can be:
•
Operator rings or watches.
•
Belt contamination even by small particles of rust.
•
Remember to clean the underside as well as the top surfaces you
can see.
•
Metallic belt clips even if plastic coated.
•
Metallic guide rails particularly into the metal free area.
Содержание IQ2
Страница 92: ...Maintenance Module 8023 6 1 Frequency links Tx Inductors Balance inductors ...
Страница 101: ...Wiring Diagrams Module 10088 8 2 Figure 1 Optional External Sensor Connection Ladder Diagram ...
Страница 102: ...Spare Parts Module 11050 9 1 SPARE PARTS CONTENTS Spare Parts Lists 2 ...
Страница 104: ...Service Return Module 12005 8 1 SERVICE RETURNS FORMS CONTENTS Instructions 2 Form 3 ...