Product Description and Environment
Module 5092
3-2
Search Head and Control Unit
This section describes Loma IQ metal detector search head and control unit.
Technical Specification
Search Head ............................................................................................................. Loma IQ
2
Case Material ......................................................................... Stainless steel 304L, fabricated
Case Finish ........................................................................................................ Bead blasted
Environmental Protection .........................................................................Dust and waterproof
Control Unit .............................................................................................................. Loma IQ
2
Mounting
................................................................................... On search head or remote
Voltage Standard Universal Input ......................................... 85-264V, single phase, 50/60Hz
Operating Temperature........................................................ -10°C to 40°C (+14°F to +104°F)
Relative Humidity ........................... 80% up to 31°C (86°F) reducing to 50% @ 40°C (104°F)
The metal detector search head and control unit has been designed for use with
continuous motion conveyor systems, pipeline, pharmaceutical and freefall
metal detectors.
As standard, the control unit is secured at the end of the search head. This unit
enables suitably trained personnel to set up, change, calibrate, and obtain
results from the system through a menu-driven user interface. The control board
can be fitted with an optional board providing the following serial link options – 1
x RS232 (hardware hand shaking). 1 x 20ma current loop, and 1 x RS422 (both
software handshaking). See the
on page 25
section later in this
manual.
The control board can also be fitted with an optional external sensor board
enabling the following functions to be supported - Product registration photoeye.
Reject device actuation or confirmation of a rejected item entering a reject
collection container, photoeye or a movement sensor can achieve this. Reject
bin full sensing photoeye. Variable speed sensing using a shaft encoder.
Remote calibration command uses a simple switch.
Содержание IQ2
Страница 92: ...Maintenance Module 8023 6 1 Frequency links Tx Inductors Balance inductors ...
Страница 101: ...Wiring Diagrams Module 10088 8 2 Figure 1 Optional External Sensor Connection Ladder Diagram ...
Страница 102: ...Spare Parts Module 11050 9 1 SPARE PARTS CONTENTS Spare Parts Lists 2 ...
Страница 104: ...Service Return Module 12005 8 1 SERVICE RETURNS FORMS CONTENTS Instructions 2 Form 3 ...