OPERATING MANUAL 

Gas-Detection

Lauper Instruments AG

Irisweg 16B 

CH-3280 Murten 

Tel. +41 26 672 30 50 

[email protected] 

www.lauper-instruments.ch

Содержание Geotech SEM5000

Страница 1: ...OPERATING MANUAL Gas Detection Lauper Instruments AG Irisweg 16B CH 3280 Murten Tel 4126 672 30 50 info lauper instruments ch www lauper instruments ch...

Страница 2: ...t 16 Measure in absolute mode ABS and relative mode REL 16 SETTING THE ALARM THRESHOLD 17 ACOUSTIC AND VISUAL ALARM 17 BACKLIGHT DISPLAY ILLUMINATION 17 BLUETOOTH DESCRIPTION OPTIONAL 17 RECHARGING TH...

Страница 3: ...Page 3 of 36 OMSEM5000 Iss 01 1 DECLARATION OF CONFORMITY...

Страница 4: ...at can be applied to the external adapter QED CCLO 100189 to charge QED LASER ONE and SEM5000 without invalidating the type of protection is 15 volts Do not connect the LASER ONE SEM5000 the battery p...

Страница 5: ...nd 2 The respect of essential safety requirements defined in annex II of the 2014 34 UE directive from 26th February 2014 is obtain by the apparatus conformity to the standards EN 60079 0 2012 A11 201...

Страница 6: ...nt of Methane concentrations in sampling mode or in line option The single dial function selector makes the SEM5000 easy to use and the large back lit LCD display provides easy to read menus and resul...

Страница 7: ...f the instrument Description 1 ON OFF button Backlight 2 Function button 3 Buzzer 4 Jogdial L LED Alarm Lights and Impact Bumpers S Carry strap Connectors Connections Description 1 Gas Sample Inlet 2...

Страница 8: ...CH4 reading YES I GPS memory J1 Type of view ABS absolute REL relative YES J2 Gas measured CH4 YES J3 Unit of Measurement PPM parts per million or VOL volume YES K Peak value over last 120 seconds NO...

Страница 9: ...isplay window A Rotate the jogdial to scroll through the available menu options Once you have identified your desired option push the jogdial to confirm your selection While a menu is active the value...

Страница 10: ...will see the message DATA TO DOWNLOAD In order to download the data the ProSoft software must be used The instrument will warm up and self calibrate The warm up will last approximately 20 seconds and...

Страница 11: ...ry used will also be displayed in the bottom left hand corner Initially only the percent symbol will be displayed Once the GPS has obtained a location fix and the SEM5000 begins saving data a number w...

Страница 12: ...ronmental Systems Limited The sample inlet port is suitable for a tube with the dimensions ID2mm X OD4 mm An internal hydrophobic filter protects the device against any ingress from dust or water An a...

Страница 13: ...pacity percentage Restarting the pump operation To turn the pump ON press the Function button the pump will restart and the X overlaying the pump icon will dissapear Saving leaks The SEM5000 instrumen...

Страница 14: ...EM5000 will automatically display the four nearest points of interest Rotate the jogdial to select a point Press the jogdial to confirm selection and a point event will be saved against the named poin...

Страница 15: ...tify proximity to a named point When within the software defined geo fence the nearest point name and proximal distance will be displayed on the main screen Additionally the green LED will be momentar...

Страница 16: ...s is typically between 1 0 and 3 0 ppm It may be desirable for the user to remove this background level of Methane during the measurement survey The Relative measurement REL allows for the user to see...

Страница 17: ...n the instrument is powered on or if a gas measured exceeds the alarm threshold an alarm will sound and the LED s will flash To disable or enable this alarm setting push the jogdial until the option f...

Страница 18: ...arge The battery level indicator on the LASER ONE SEM5000 consists of three segments the last of which indicates that there is approximately 30 minutes of power remaining The typical operational time...

Страница 19: ...INTENANCE Replacing the Battery Pack Warning Replace the battery pack only in a non hazardous safe area Allen Key 3mm Battery pack The picture shows the battery removed from the instrument itsompartme...

Страница 20: ...e end of the wand The second is a cellulose fibre filter for fine dust particles and is located at the top of the rubber housing Both filters should be replaced periodically It is recommended that at...

Страница 21: ...Page 21 of 36 OMSEM5000 Iss 01 To change the bronze dust filter To change the cellulose dust filter...

Страница 22: ...extendable sample probe contains a 1 5 metre section of tubing that directs the sample into the instrument Should the tube become kinked or fractured it must be replaced to avoid restricting the pump...

Страница 23: ...Page 23 of 36 OMSEM5000 Iss 01...

Страница 24: ...Page 24 of 36 OMSEM5000 Iss 01...

Страница 25: ...nderside adjacent to the battery charging connector The hydrophobic internal filter should be checked periodically typically this will be weekly during periods of heavy use Alarms and Error Informatio...

Страница 26: ...Laser fails to stabilise properly Turn the instrument off and on again If the error persists contact technical qedenv co uk The display shows Laser sensor error 142 Laser fails to stabilise properly...

Страница 27: ...arge for the replacement part If no fault is found an investigation charge may apply QED s Technical Support MUST be notified in the event of a pending warranty claim They will then issue a returns re...

Страница 28: ...ree month warranty period following a QED service to cover any defects that have arisen because of that service QED Environmental Systems reserve the right to update these terms and conditions without...

Страница 29: ...correctly or damaged as a result of improper use Note QED Environmental Systems Ltd is committed to constant improvement to develop our products If the SEM5000 is serviced by unqualified engineers th...

Страница 30: ...00 ATEX Car cable power supply SEM5000 ATEX 900011 100060 100157 507103 402004 Suction Probe Carpet probe On demand pressure regulator Gas check cylinder Methane 10ppm Dust filter for probes Package o...

Страница 31: ...is classified Class 1 according European standards Do not open the device Other precautions for the usage The charging of the batteries must be in a safe place with the appropriate external adapter T...

Страница 32: ...activated Case Carbon reinforced polyamide with fiberglass Dimensions L x w x h 229 x 97 x 109mm Weight 1 3Kg in operation Protection level IP65 Environmental storage conditions excluding batteries Hu...

Страница 33: ...rical and Electronic Equipment directive WEEE makes producers responsible from July 1st 2007 in meeting their obligations with the fundamental aim of reducing the environmental impact of electrical an...

Страница 34: ...ult the dealer or an experienced radio TV technician for help Canada The device contains transmitter module IC 6514A RN42 This device complies with Industry Canada license exempt RSS standard s Operat...

Страница 35: ...1 Europe The Bluetooth module has been tested to R TTE Directive 1999 5 EC Essential Requirements for Health and Safety Article 3 1 a Electromagnetic Compatibility EMC Article 3 1 b and Radio Article...

Страница 36: ...Page 36 of 36 OMSEM5000 Iss 01 www qedenv com Gas Detection Lauper Instruments AG Irisweg 16B CH 3280 Murten Tel 4126 672 30 50 info lauper instruments ch www lauper instruments ch...

Отзывы: