Configuration and Set up Information
Module 7026
5-12
CTB Constant:
This parameter is the number of pulses (ticks) per metre/foot of belt travel. To
calculate this figure for entry into the “*CTB constant” menu position, use either
the metric or imperial formula following:
Metric systems:
CTB =
Encoder pulses per revolution x 1000
π
d
Where:
d = the diameter of the roller to which the encoder is fitted in millimetres.
Imperial systems:
CTB =
Encoder pulses per revolution x 12
π
d
Where:
d = the diameter of the roller to which the encoder is fitted in inches.
The maximum allowable CTB rate must not exceed 100 pulses per second. The
calculation to confirm this figure is as follows:
Maximum belt speed x CTB constant
=
< =100
60
The minimum allowable CTB rate to ensure accurate reject resolution must
exceed 4 pulses per coil gap. The coil gap distance for your detector (Rx) can
be found on the serial number plate located inside the control unit or from the
coil gap chart located earlier in this section.
The calculation to confirm the minimum number of pulses is as follows:
Metric systems:
Coil Gap x [CTB constant x minimum belt speed] > = 4
1000
Where:
The coil Gap is in millimetres. The minimum belt speed is in metres.
Imperial systems:
Coil Gap x [CTB constant x minimum belt speed] > = 4
12
Where:
The coil Gap is in inches. The minimum belt speed is in feet per
minute.
Содержание IQ2
Страница 92: ...Maintenance Module 8023 6 1 Frequency links Tx Inductors Balance inductors ...
Страница 101: ...Wiring Diagrams Module 10088 8 2 Figure 1 Optional External Sensor Connection Ladder Diagram ...
Страница 102: ...Spare Parts Module 11050 9 1 SPARE PARTS CONTENTS Spare Parts Lists 2 ...
Страница 104: ...Service Return Module 12005 8 1 SERVICE RETURNS FORMS CONTENTS Instructions 2 Form 3 ...