Maintenance
Module 8023
6-9
-
Switch off the detector power.
-
Fit link 1-2 on JP6.
-
Switch on the detector power.
-
The display will show + Not det
-
Power down.
-
Remove the link.
-
Power up.
-
Re-configure the detector menus.
If the link is not removed then a warning m Warning JP6 + will be
displayed and exit from the “Configuration” menu will be denied until the link is
removed.
CONTROL BOARD LINKS AND TEST POINTS
on page 6
in this section shows all user link and test point information.
For clarity user links and test points together with their uses are referred to in
the relevant sections through out this manual.
Following are tables of the remaining control board links that are shown only for
completeness of information.
Link
Use
Default setting
JP7
Time base source selection
Link 2-3 (internal)
JP10
0V signal Ground
IN
Following is a table of the control board test points that are shown only for
completeness of information.
Test Point
Use
TP1
Reject relay drive monitor
TP2
Fault relay drive monitor
TP3
Attention relay drive monitor
TP4
In run relay drive monitor
TP5
ADC reference voltage
TP6
R channel ADC input
TP7
X channel ADC Input
TP8
R channel head board output
TP9
X channel head board output
TP10
PSU switching frequency
TP11
Head balance
TP14
Not used
Содержание IQ2
Страница 92: ...Maintenance Module 8023 6 1 Frequency links Tx Inductors Balance inductors ...
Страница 101: ...Wiring Diagrams Module 10088 8 2 Figure 1 Optional External Sensor Connection Ladder Diagram ...
Страница 102: ...Spare Parts Module 11050 9 1 SPARE PARTS CONTENTS Spare Parts Lists 2 ...
Страница 104: ...Service Return Module 12005 8 1 SERVICE RETURNS FORMS CONTENTS Instructions 2 Form 3 ...