29. Technical data

29. Technical data

30. Type test

30. Type test

The Lohberger Pellet module was successfully tested by the Technical University 
of Vienna according to the current European Standards.

Report testing institute no . PL-0418-P-E

Die Emissionen gemäß Art. 15a B-VG über Schutzmaßnahmen und über die 
Einsparung von Energie werden eingehalten.

Furthermore, amongst others the following exhaust gas limits according to 
the following German standards are observed: Regensburger Norm, Stuttgarter 
Norm and Münchner Verordnung.

table 3

LCP 70

LCP 75 A

LCP 75 B

LCP 80

F1+B1+P

F1+B2+P

F2+B1+P

F2+B2+P

Filling door opening

width x hight

mm

135 x 245

185 x 245

Filling space  

depth x width

mm

150 x 355

200 x 355

Fuel filling height

mm

100

100

Oven

width x hight x deoth

mm

320 x 290 x 

410

370 x 290 x 

410

320 x 290 x 

410

370 x 290 x 

410

Cooking surface 

width x depth

mm

657 x 507

707 x 507

707 x 507

757 x 507

area

m

2

0,33

0,36

0,36

0,38

Ash drawer

stove

litre

4,5

6,2

pellet module

litre

5,8

5,8

Fuel storage container 

stove

litre

33,2

36,5

36,5

39,8

pellet module

litre / kg

18 / ~15

18 / ~15

Fuel consumption

output min. / max.

kg / h

~ 0,9 / ~1,5

~ 0,9 / ~1,5

Heating period max.

output min. / max.

h

~ 16 / ~10

~ 16 / ~10

central heating insert *

capacity

litre

-

~ 11

Operation pressure *

max.

bar

-

3

Operation temperature *

max.

°C

-

95

Baking sheet 

width x depth

mm

300 x 400

350 x 400

300 x 400

350 x 400

Grid

width x depth

mm

300 x 400

350 x 400

300 x 400

350 x 400

Weight (packaging in-
cluded)

built-in cupboard enamel 
panelling

kg

ca. 310

ca. 322

ca. 325

ca. 337

Packaging

kg

ca. 30 – 40

ca. 30 – 40

Output data:

Data for chimney calculation (according to DIN 4705)

Tated heat output 

wood / pellet

kW

6 / 7

7 (9*)  / 7 (9*)

Room heating output *

wood / pellet

kW

- / -

4,5 / 5

Water heating output *

wood / pellet

kW

- / -

4,5 / 4

Flue gas temperature 

wood / pellet

°C

210 / 160

220 (150*) / 160 (160*)

Flue gas mass flow

wood / pellet

g/s

6 / 7

7 (7*) / 8,5 (8,5*)

Necessary delivery pres-
sure

at NWL

mbar

0,12 / 0,12

0,11 (0,12*) / 0,12 (0,12*)

* ... these specifications apply to stoves with built-in central heating insert (type designation –Z, optional)

Elektrical data

Current supply

230 V AC / 50 Hz

Power input (start / operation)

360 W / 50 W

Содержание LCP 70

Страница 1: ...page 1 Edition July 2010 USER MANUAL WITH INSTALLATION INSTRUCTIONS GB PELLETS MODULE P6 P7 LCP 70 LCP 75A LCP 75B Z LCP 80 Z...

Страница 2: ...12 16 Menu Top level 12 Switching on the appliance 12 Switching off the appliance 12 Setting the heating output 12 18 Main menu 13 17 Menu Settings 13 Keylock 13 Time Date 13 Automatic mode 14 Heatin...

Страница 3: ...M B8131 Closed water heating systems safety requirements NORM B8133 Safety requirements water heating systems DIN 4751 Part 1 Safety equipment for heating systems with supply temperatures up to 110 C...

Страница 4: ...existing defects and or alterations regarding the chimney and the heating system Due to low exhaust gas temperatures during changes in season it is imperative that the chimney is tight and unsuscepti...

Страница 5: ...contact shifter 12 Drive shaft rotary feeder 13 Driving chain conveying unit 14 Auger motor 15 Grate Motor 16 Flame temperature sensor 1 Cover 2 Control panel 3 Sidewall built in cupboard 4 Base pane...

Страница 6: ...y ensures that flue gases escape through the chimney The pellet stove can be operated either with wood pellets or billet wood Operation with pellets The operation with pellets is predominantly suitabl...

Страница 7: ...Wood pellets It is imperative that only wood pellets conforming to the Austrian standards NORM M7135 or DIN Plus are used Diameter 6 mm length max 30 mm Storage of wood pellets Pellets are supplied w...

Страница 8: ...bustible materials must be a maxi mum of 4 m in length and must not have too many bends To avoid condensation the air supply line must be insulated The air flue must be at least 50 or 100 mm respectiv...

Страница 9: ...tallation of a smoke detector or fire warning device which interrupts the current supply of the appliance in case of an emergency Objects which have been left inadvertently on the cooking surface are...

Страница 10: ...appliance height standard height 85 cm Fixtures which are higher f e tall cupboard have to be at least 20 cm from the pellets module away figure 9 Overhead installations Maintain a minimum distance o...

Страница 11: ...base and fas ten it at the top with both supplied screws J1 Use adjusting screws to level out unevenness of the floor and distances in height figure 15 Connections main plate Provide the connections...

Страница 12: ...and to switch from one adjustment point to the next in the ad justment levels To confirm error messages by pressing and holding the button approx 2 seconds 15 Operation Settings 15 Operation Settings...

Страница 13: ...menu press the OK button once Settings To perform appliance settings Information Display Information on the appliance and its components Default setting Detailed settings service technician 17 Menu S...

Страница 14: ...eration determines whether the appliance is operated manually standard setting OFF or whether the internal clock is used for switching the ap pliance on off The automatic operation determines whether...

Страница 15: ...text box figure 36 Press OK button once repeat the steps for the entry of the service code and enter the correct service code Press button twice to return to the top level of the menu To confirm clea...

Страница 16: ...s adjustment range of the pellet burner Boiler set point temperature WINTER 75 C Boiler set point temperature SUMMER 65 C 19 Menu Informations 19 Menu Informations To enter the menu Information from t...

Страница 17: ...rrent value ON OFF OFF Blower off Current value ON OFF OFF Motor off ON OFF OFF Ignition off ON OFF OFF Pump off only for appliances with central heating insert Press button three times to return to t...

Страница 18: ...he stove is in use temperatures up to 300 C Pay attention to the fact that these parts must not be touched when the stove is in operation Keep the firebox door closed at all times even if the stove is...

Страница 19: ...onto the grate 1 6 kg to 2 kg according to the operating instructions of the stove Close heating door Ignition of firewood manually operated The display still shows Stove OFF or Burner OFF figure 58 S...

Страница 20: ...ally at any time Objects that have been inadvertently placed on the cooking surface could ignite if the pellet burner starts up automatically e g start up according to a pre programmed time and start...

Страница 21: ...with the cleaning and or maintenance the appliance must be shut down and disconnected from the mains Emergency OFF Allow the appliance to cool down nevertheless we advise you to be careful some compon...

Страница 22: ...Ash pan can be hot fig 71 fig 72 In the event of an error message the display begins to flash Remedy the defect with the aid of the following list of defects and subsequently confirm the error messag...

Страница 23: ...en sensor short circuit Call service technician Flue gas sensor ub oven sensor failure Cause see flame sensor UB Solution see flame sensor UB F11 ignition programm after power failure power failure Pl...

Страница 24: ...litre 4 5 6 2 pellet module litre 5 8 5 8 Fuel storage container stove litre 33 2 36 5 36 5 39 8 pellet module litre kg 18 15 18 15 Fuel consumption output min max kg h 0 9 1 5 0 9 1 5 Heating period...

Страница 25: ...PE 7 PE PE 6 5 4 3 PE 1 2 3 4 9 5 PE 10 PE PE blue Earthing brown Mains connection Serial input output RS 232 Maintenance Update Fuse Micro fuse 5 x 20 mm 2 5 A T Ceramic body Control panel J1 J2 J3...

Страница 26: ...t reduce output stove on off only information only information only information scroll with UP DOWN only information scroll with UP DOWN settings from customer reset with OK brand with OK selection wi...

Страница 27: ...e in which way the defect should be repaired In the event of a repair we ensure expert performance on location or in our works This does not affect the start of warranty determined by the handover if...

Страница 28: ...KEY LOCK function OK Stove ON 13 45 Burner ON Output OK Stove ON 13 45 Burner ON Output OK Stove OFF 13 45 NO PELLETS Output OK Stove ON 13 45 Burner ON Output OK Stove ON 13 45 Burner ON Output Pres...

Отзывы: