LOHBERGER LCP 70 Скачать руководство пользователя страница 16

--   Settings   --

 Service code      |%

 reset             |

>Summer/Winter <   |

--  Summer/Winter  --

>Winter mode <

 

--  Summer/Winter  --

>Summer mode <

 

--   Main menue   --

 Settings   

>informations <

 Default setting

-- informations  --
>Sensors <           |
 actuators           |

 System/SWversion   |%

--  informations  --
>Sensors <           |
 actuators           |

 System/SWversion   |%

--    Sensors    --

>Door cntact    ON< |

 grate contact  ON  |

 release        ON  |%

--    Sensoren    --

 t Flame        38  |%

 t Flue gas     26  |

>t Plug-in      24< |%

--    Sensors    --

 t Flue gas     26  |%

 t Plug-in      24  |

>t Boiler       29< |

page 16

Summer/Winter 

(only for appliances with central heating insert)

Select the menu 

SUMMER/WINTER

 by pressing  

 

   

or  

 

   

and press the   

OK

  button once (figure 38).

The setting can be changed by pressing the buttons 

 

 

or

 

 

 (figure 40/41).

Press 

 button three times to return to the top level of the menu.

To reduce heat output in summer, the appliance can be changed from winter to 
summer mode. This setting limits the upwards adjustment range of the pellet 
burner.

 

• Boiler set-point temperature WINTER 75°C

 

• Boiler set-point temperature SUMMER 65°C

To reduce heat output in summer, the appliance can be changed from winter to 
summer mode. This setting limits the upwards adjustment range of the pellet 
burner.

 

• Boiler set-point temperature WINTER 75°C

 

• Boiler set-point temperature SUMMER 65°C

19. Menu Informations

19. Menu Informations

To enter the menu 

Information

 from the main menu, select the menu 

Informa-

tion

 by pressing the button 

 

 

or

 

 

 and press the 

OK

 once (figure 42).

Sensors

Passive appliance components such as sensors, …

Actuators

Active appliance components such as motors, blowers, …

Appliance / SW 
Version

 

Display of the pre-set appliance type and of the installed 
software version.

Operating hours

 

Display of the total amount of operating hours as well as 
how many operating hours are left until the next mainte-
nance of the appliance is due.

Sensors

Select the menu 

Sensors

 in the menu 

Information

 by pressing the button 

 

 

or 

 

 

 and press the 

OK

 once (figure 44)

Paging through the menu items is possible by pressing the button 

 

 

or

 

 

 

(figure 45-47).

ON /OFF (OFF = door open)

ON /OFF (OFF = grate open)

ON /OFF (OFF = no external command)

Current flame temperature

Current exhaust gas temperature

Current discharge chute temperature

Current boiler temperature – (only for appliances with central heating insert)

Press 

 three times to return to the top level of the menu.

fig. 40

fig. 41

fig. 42

fig. 43

fig. 44

fig. 45

fig. 46

fig. 47

fig. 48

Содержание LCP 70

Страница 1: ...page 1 Edition July 2010 USER MANUAL WITH INSTALLATION INSTRUCTIONS GB PELLETS MODULE P6 P7 LCP 70 LCP 75A LCP 75B Z LCP 80 Z...

Страница 2: ...12 16 Menu Top level 12 Switching on the appliance 12 Switching off the appliance 12 Setting the heating output 12 18 Main menu 13 17 Menu Settings 13 Keylock 13 Time Date 13 Automatic mode 14 Heatin...

Страница 3: ...M B8131 Closed water heating systems safety requirements NORM B8133 Safety requirements water heating systems DIN 4751 Part 1 Safety equipment for heating systems with supply temperatures up to 110 C...

Страница 4: ...existing defects and or alterations regarding the chimney and the heating system Due to low exhaust gas temperatures during changes in season it is imperative that the chimney is tight and unsuscepti...

Страница 5: ...contact shifter 12 Drive shaft rotary feeder 13 Driving chain conveying unit 14 Auger motor 15 Grate Motor 16 Flame temperature sensor 1 Cover 2 Control panel 3 Sidewall built in cupboard 4 Base pane...

Страница 6: ...y ensures that flue gases escape through the chimney The pellet stove can be operated either with wood pellets or billet wood Operation with pellets The operation with pellets is predominantly suitabl...

Страница 7: ...Wood pellets It is imperative that only wood pellets conforming to the Austrian standards NORM M7135 or DIN Plus are used Diameter 6 mm length max 30 mm Storage of wood pellets Pellets are supplied w...

Страница 8: ...bustible materials must be a maxi mum of 4 m in length and must not have too many bends To avoid condensation the air supply line must be insulated The air flue must be at least 50 or 100 mm respectiv...

Страница 9: ...tallation of a smoke detector or fire warning device which interrupts the current supply of the appliance in case of an emergency Objects which have been left inadvertently on the cooking surface are...

Страница 10: ...appliance height standard height 85 cm Fixtures which are higher f e tall cupboard have to be at least 20 cm from the pellets module away figure 9 Overhead installations Maintain a minimum distance o...

Страница 11: ...base and fas ten it at the top with both supplied screws J1 Use adjusting screws to level out unevenness of the floor and distances in height figure 15 Connections main plate Provide the connections...

Страница 12: ...and to switch from one adjustment point to the next in the ad justment levels To confirm error messages by pressing and holding the button approx 2 seconds 15 Operation Settings 15 Operation Settings...

Страница 13: ...menu press the OK button once Settings To perform appliance settings Information Display Information on the appliance and its components Default setting Detailed settings service technician 17 Menu S...

Страница 14: ...eration determines whether the appliance is operated manually standard setting OFF or whether the internal clock is used for switching the ap pliance on off The automatic operation determines whether...

Страница 15: ...text box figure 36 Press OK button once repeat the steps for the entry of the service code and enter the correct service code Press button twice to return to the top level of the menu To confirm clea...

Страница 16: ...s adjustment range of the pellet burner Boiler set point temperature WINTER 75 C Boiler set point temperature SUMMER 65 C 19 Menu Informations 19 Menu Informations To enter the menu Information from t...

Страница 17: ...rrent value ON OFF OFF Blower off Current value ON OFF OFF Motor off ON OFF OFF Ignition off ON OFF OFF Pump off only for appliances with central heating insert Press button three times to return to t...

Страница 18: ...he stove is in use temperatures up to 300 C Pay attention to the fact that these parts must not be touched when the stove is in operation Keep the firebox door closed at all times even if the stove is...

Страница 19: ...onto the grate 1 6 kg to 2 kg according to the operating instructions of the stove Close heating door Ignition of firewood manually operated The display still shows Stove OFF or Burner OFF figure 58 S...

Страница 20: ...ally at any time Objects that have been inadvertently placed on the cooking surface could ignite if the pellet burner starts up automatically e g start up according to a pre programmed time and start...

Страница 21: ...with the cleaning and or maintenance the appliance must be shut down and disconnected from the mains Emergency OFF Allow the appliance to cool down nevertheless we advise you to be careful some compon...

Страница 22: ...Ash pan can be hot fig 71 fig 72 In the event of an error message the display begins to flash Remedy the defect with the aid of the following list of defects and subsequently confirm the error messag...

Страница 23: ...en sensor short circuit Call service technician Flue gas sensor ub oven sensor failure Cause see flame sensor UB Solution see flame sensor UB F11 ignition programm after power failure power failure Pl...

Страница 24: ...litre 4 5 6 2 pellet module litre 5 8 5 8 Fuel storage container stove litre 33 2 36 5 36 5 39 8 pellet module litre kg 18 15 18 15 Fuel consumption output min max kg h 0 9 1 5 0 9 1 5 Heating period...

Страница 25: ...PE 7 PE PE 6 5 4 3 PE 1 2 3 4 9 5 PE 10 PE PE blue Earthing brown Mains connection Serial input output RS 232 Maintenance Update Fuse Micro fuse 5 x 20 mm 2 5 A T Ceramic body Control panel J1 J2 J3...

Страница 26: ...t reduce output stove on off only information only information only information scroll with UP DOWN only information scroll with UP DOWN settings from customer reset with OK brand with OK selection wi...

Страница 27: ...e in which way the defect should be repaired In the event of a repair we ensure expert performance on location or in our works This does not affect the start of warranty determined by the handover if...

Страница 28: ...KEY LOCK function OK Stove ON 13 45 Burner ON Output OK Stove ON 13 45 Burner ON Output OK Stove OFF 13 45 NO PELLETS Output OK Stove ON 13 45 Burner ON Output OK Stove ON 13 45 Burner ON Output Pres...