protective cap
reset button (red)
Stove ON 13:45
NO PeLLetS
Output <||
||
|
||
||
|
||
||
|
||
||
|
||
||
|
||
||
|
--->
If the maximum permissible boiler temperature of 95 °C is exceeded, the safety
temperature limiter, in short STB, is activated and the display shows the error
message
StB activateD
. After having cooled down, the STB must be reset
manually (figure 71)
•
Remove the base panel of the pellet module.
•
Screw off black protective cap and press the red reset button.
•
Reset the error message by pressing the button
OK
.
page 22
Cleaning ash pan
(figure 70)
•
Remove the base cover front (
H1
).
•
Pull out the ash pan (in a forward direction).
•
Empty ash pan and clean ash drawer space.
Vacuum-cleaning ash drawer space
Allow the appliance to cool down completely and use vacuumcleaner only in
combination with an » Ash Box « – Fire hazard!
28. Resetting safety temperature limiter
(only with central heating appliances)
28. Resetting safety temperature limiter
(only with central heating appliances)
CAUTION! Ash pan can be hot!!
CAUTION! Ash pan can be hot!!
fig. 71
fig. 72
In the event of an error message the display begins to flash.
Remedy the defect with the aid of the following list of defects and subsequently
confirm the error message. To do so, press and hold the OK button (for approx.
2 seconds) in the top level of the menu.
27. Error messages / Remedy of defects
27. Error messages / Remedy of defects
Display
Fault
Possible cause
Solution
NO PeLLetS
No pellets have been transported/
pellets storage container empty
Container empty
Add fuel
Grate dirty
Empty ash pan (in operating position
StOve OFF
)
Conveyor drive
Clean auger or contact your service centre
Air regulator open
Close air regulator
Insufficient supply of fresh air
Ensure permanent supply of fresh air
Ash pan full
Empty ash pan (in operating position
StOve OFF
)
NOt igNiteD
No ignition /no ignition after
power failure
Heating door open
Close heating door
Heating damper open
Close heating damper
Ash pan full
Empty ash pan (in operating position
StOve OFF
)
Flue opening clogged
Clean appliance
Air regulator open
Close air regulator
Insufficient supply of fresh air
Ensure permanent supply of fresh air
Container empty