6 CONNECTING THE SYSTEM
The SMARTneo-2G can be used to create a variety of Table Systems. This Manual describes the connection
of table systems in which two Control Boxes will be connected.
This chapter describes the process of connecting the Cascading System’s components after they have been
mounted to the Height-Adjustable Table System. You must read the documentation for each part of the sys-
tem (Actuator, User Interface, Control Box, etc.) for that product’s mounting instructions.
This Chapter outlines three common configurations for Cascading Systems. For further information con-
cerning other cascading options for the SMARTneo-2gen, please contact LOGICDATA.
6.1 SAFETY
WARNING Moderate risk of death or serious injury through electric shocks
Connecting the system incorrectly can lead to serious injury through electric shocks.
• Ensure that the supplied voltage complies with the SMARTneo-2G's type plate
• Ensure all components are connected to the correct sockets
• Do not use unauthorized accessory parts or cables
• Disconnect the SMARTneo-2G from the power outlet before removing or connect-
ing any components
• Connect the system to the Mains only after all other components (Actuators, addi-
tional Control Boxes etc.) have been connected to the SMARTneo-2G
WARNING Moderate risk of death or serious injury through electric shocks
Using damaged products may lead to death or serious injury through electric shocks.
• Do not operate the Cascading System if you see housings or cables are damaged
NOTICE
Ensure proper ESD handling during assembly. Damage that can be attributed to electro-
static discharge will void warranty claims.
NOTICE
This manual is applicable for Cascading Systems with the SMARTneo-2G Control Box.
SMARTneo-2G Control Boxes cannot be connected to any other type of Control Box.
Connecting incompatible Control Boxes may damage the Table System.
INFO
Perform a product risk assessment so that you can respond to potential residual haz-
ards. Assembly instructions must be included in your end user Operating Manual
6.2 DIMENSIONS
The dimensions of each product in the Table System can be found in that product’s Datasheet.
6.3 ASSEMBLY INSTRUCTIONS
Assembly instructions for each product in the Table System can be found in that product’s Manual.
6.4 SPECIFICATIONS FOR THE CASCADING SYSTEM
Before connecting the Cascading System, make sure that the following requirements are met:
• Assembly has been completed safely and correctly for all components
• All Actuators are of the same type (e.g. SLIMdrive-660s or SLIMdrive-500)
• The Control Boxes are set to factory settings (Chapter 7.2 Factory Reset, page 18) or have
been correctly parameterized. Otherwise, a Factory Reset is required during setup.
• The voltage supply corresponds to the specifications on the respective type plate