background image

SMARTNEO-2G: CASCADING MANUAL // PAGE 14

6  CONNECTING THE SYSTEM

The SMARTneo-2G can be used to create a variety of Table Systems. This Manual describes the connection 
of table systems in which two Control Boxes will be connected. 

This chapter describes the process of connecting the Cascading System’s components after they have been 
mounted to the Height-Adjustable Table System. You must read the documentation for each part of the sys-
tem (Actuator, User Interface, Control Box, etc.) for that product’s mounting instructions. 

This Chapter outlines three common configurations for Cascading Systems. For further information con-
cerning other cascading options for the SMARTneo-2gen, please contact LOGICDATA.

6.1  SAFETY

WARNING Moderate risk of death or serious injury through electric shocks

Connecting the system incorrectly can lead to serious injury through electric shocks. 

•  Ensure that the supplied voltage complies with the SMARTneo-2G's type plate

•  Ensure all components are connected to the correct sockets

•  Do not use unauthorized accessory parts or cables

•  Disconnect the SMARTneo-2G from the power outlet before removing or connect-

ing any components

•  Connect the system to the Mains only after all other components (Actuators, addi-

tional Control Boxes etc.) have been connected to the SMARTneo-2G

WARNING Moderate risk of death or serious injury through electric shocks

Using damaged products may lead to death or serious injury through electric shocks.

•  Do not operate the Cascading System if you see housings or cables are damaged 

NOTICE

Ensure proper ESD handling during assembly. Damage that can be attributed to electro-

static discharge will void warranty claims.

NOTICE

This manual is applicable for Cascading Systems with the SMARTneo-2G Control Box. 

SMARTneo-2G Control Boxes cannot be connected to any other type of Control Box. 

Connecting incompatible Control Boxes may damage the Table System.

INFO

Perform a product risk assessment so that you can respond to potential residual haz-

ards. Assembly instructions must be included in your end user Operating Manual

6.2  DIMENSIONS

The dimensions of each product in the Table System can be found in that product’s Datasheet. 

6.3  ASSEMBLY INSTRUCTIONS

Assembly instructions for each product in the Table System can be found in that product’s  Manual. 

6.4  SPECIFICATIONS FOR THE CASCADING SYSTEM

Before connecting the Cascading System, make sure that the following requirements are met:

•  Assembly has been completed safely and correctly for all components
•  All Actuators are of the same type (e.g. SLIMdrive-660s or SLIMdrive-500)
•  The Control Boxes are set to factory settings (Chapter 7.2 Factory Reset, page 18) or have 

been correctly parameterized. Otherwise, a Factory Reset is required during setup. 

•  The voltage supply corresponds to the specifications on the respective type plate

Содержание SMARTneo-2G

Страница 1: ...MANUAL Document Version 1 0 July 2019 SMARTneo 2G Cascading...

Страница 2: ...rman language version is the original LOGICDATA Electronic Software Entwicklungs GmbH Wirtschaftspark 18 8530 Deutschlandsberg Austria Phone 43 0 3462 51 98 0 Fax 43 0 3462 51 98 1030 Internet http ww...

Страница 3: ...t documentation before connecting the components to form a Cascading System and putting it into operation Required components For detailed instructions see the Required Components subchapter for your...

Страница 4: ...g System with 2 Actuators For detailed instructions see chapter 6 3 5 on page 15 1 2 SA VE 3 4 1 2 SA VE 3 4 Cascading System with 3 Actuators For detailed instructions see chapter 6 6 on page 16 1 2...

Страница 5: ...nstructions see chapter 6 7 on page 17 1 2 SA VE 3 4 1 2 S A V E 3 4 Performing the Reference Drive For detailed instructions see chapter 7 1 on page 18 O73 Factory Reset For detailed instructions see...

Страница 6: ...5 Explanation of symbols and signal words 10 3 6 Liability 10 3 7 Residual risks 11 3 8 Skilled Persons 12 3 9 Notes for Resellers 12 4 Scope of delivery 12 5 Product 13 5 1 About Cascading 13 5 2 Ab...

Страница 7: ...the Components 17 7 Operation 18 7 1 Reference Drive 18 7 2 Factory Reset 18 7 2 1 With a Basic Hand Control 18 7 2 2 With a Comfort Hand Control 19 8 Troubleshooting 20 8 1 Lexicon 20 8 2 Possible P...

Страница 8: ...After purchase and full payment of the product all text and images in Chapter 3 Safety may be used free of charge by the customer for 10 years after delivery They should be used to prepare end user d...

Страница 9: ...is a Control Box for electrically Height Adjustable Tables It is intended for indoor use only The system may only be installed in compatible Height Adjustable Tables and with LOGICDATA approved acces...

Страница 10: ...r sources INFO Indicates important tips for handling the product 3 6 LIABILITY LOGICDATA products comply with all currently applicable health and safety regulations However risk can result from incorr...

Страница 11: ...ks While cleaning or using the system liquid intrusion may lead to serious injury through electric shocks Do not allow any components to become wet during cleaning Ensure components are placed away fr...

Страница 12: ...l in their native EU official language INFO The Charter of the French Language La charte de la langue fran aise or Bill 101 Loi 101 guarantees the right of the population of Quebec to conduct business...

Страница 13: ...also dependent on parameterization NOTICE This Cascading Manual is only valid for the SMARTneo 2G 2nd generation Consult your product s Datasheet and Type Plate to ensure this is the correct Manual f...

Страница 14: ...risk of death or serious injury through electric shocks Using damaged products may lead to death or serious injury through electric shocks Do not operate the Cascading System if you see housings or c...

Страница 15: ...n each system 1 LOG CBL SMARTneo SYNC 1000 Sync Cable 2 Power Cables 6 5 2 CONNECTING THE COMPONENTS 1 Connect the first Actuator to a Control Box M1 2 Connect the second Actuator to the second Contro...

Страница 16: ...h system 1 LOG CBL SMARTneo SYNC 1000 Sync Cable 2 Power Cables 6 6 2 CONNECTING THE COMPONENTS 1 Connect the first two Actuators to a Control Box M1 and M2 2 Connect the third Actuator to the second...

Страница 17: ...LOG CBL SMARTneo SYNC 1000 Sync Cable 2 Power Cables 6 7 2 CONNECTING THE COMPONENTS 1 Connect the first two Actuators to a Control Box M1 and M2 2 Connect the third and fourth Actuators to the secon...

Страница 18: ...erence Drive must be performed after the Cascading System has been connected for the first time Ensure that all components are connected correctly Press and hold the DOWN Key The Actuators start up at...

Страница 19: ...settings It is now in the same state as it was during the first start up INFO Resetting the Master Control Box in the system to factory settings will automatically reset the Slave Control Box INFO If...

Страница 20: ...r 8 2 POSSIBLE PROBLEMS AND THEIR SOLUTIONS Error code malfunction Possible cause Solution E7O Actuator configuration has been changed Disconnect the Control Boxes from the power supply for approx 30...

Страница 21: ...tor from the Control Box 2 Connect the new Actuator to the Control Box 3 Perform a Reference Drive see chapter 7 1 9 1 3 UNGROUPING A CASCADING SYSTEM 1 Reset the Control Boxes to factory settings see...

Страница 22: ...rk 18 8530 Deutschlandsberg Austria Phone 43 0 3462 5198 0 Fax 43 0 3462 5198 1030 Email office at logicdata net Internet http www logicdata net LOGICDATA North America Inc 1525 Gezon Parkway SW Suite...

Отзывы: