SMARTNEO-2G: CASCADING MANUAL // PAGE 15
6.5 CASCADING SYSTEM WITH TWO ACTUATORS
INFO
When a Hand Control is connected to a Cascading System for the first time, the
Control Box it is connected to becomes the master. The other Control Box is the slave.
If you wish to change which Control Box is the master, a factory reset is required.
6.5.1 REQUIRED COMPONENTS
Quantity
Component
1
Hand Control
2
SMARTneo-2G Control Boxes
2
Actuators. Only one type of Actuator (e.g. SLIMdrive-660s) can be used in each system
1
LOG-CBL-SMARTneo-SYNC-1000 Sync Cable
2
Power Cables
6.5.2 CONNECTING THE COMPONENTS
1. Connect the first Actuator to a Control Box (M1)
2. Connect the second Actuator to the second Control Box (M1)
3. Connect the two Control Boxes using the Sync Cable (COM/DC)
4. Connect the Hand Control to a Control Box (HC)
5. Connect each Control Box to a separate Power Cable (AC)
6. Connect the Power Cables to the power source
▸ Each Control Box emits two short clicks
▸ (If a Comfort Hand Control is used) The display on the Hand Control shows
OOO
7. If the Control Boxes were not previously set to factory settings, perform a Factory Reset (Chapter
7.2, page 18)
1
2
SAVE
3
4
1
2
SAVE
3
4
1
2
3
4
5
6