background image

SMARTNEO-2G: CASCADING MANUAL // PAGE 11

3.7  RESIDUAL RISKS

Residual risks are the risks that remain after all relevant safety standards have been complied with. These 
have been evaluated in the form of a risk assessment. Residual risks associated with the connection and opera-
tion of the Cascading System are listed in this Manual. The risks associated with the installation of other prod-
ucts in the system, including the SMARTneo-2G, are detailed in the respective product’s Operating Manual. 
See also Chapter 2.1. The symbols and signal words used in this Operating Manual are listed in Chapter 3.5.

WARNING Risk of death or serious injury through electric shocks

The products in the Cascading System are electrical devices. Basic safety precautions 

must be taken at all times. Failure to observe electrical safety precautions may lead to 

death or serious injury through electric shocks. 

•  Never open any product or its components

•  Ensure that products are not connected to the mains during assembly

•  Ensure that the SMARTneo-2G is supplied with the mains voltage specified on the 

Type Plate

•  Do not convert or modify any product in any way

•  Do not place Cables on heated surfaces

•  Do not immerse any components in liquid. Clean only with a dry, soft cloth

•  Check all housings and cables for visible damage. Do not install or operate dam-

aged products. 

WARNING Risk of death or serious injury in explosive atmospheres

Operating the system in potentially explosive atmospheres may lead to death or serious 

injury through explosions.

•  Read the relevant directives to determine if an atmosphere is potentially explosive

•  Do not operate the system in potentially explosive atmospheres

WARNING Moderate risk of serious injury through electric shocks

While cleaning or using the system, liquid intrusion may lead to serious injury through 

electric shocks. 

•  Do not allow any components to become wet during cleaning

•  Ensure components are placed away from areas where spillages are likely to occur

•  Take care not to spill liquids onto or around the system

WARNING Moderate risk of serious injury through electric shocks

Inserting cables incorrectly may lead to death or serious injury through electric shocks. 

•  Ensure only LOGICDATA-approved products are connected to the SMARTneo-2G

•  Do not insert incompatible cables into the SMARTneo-2G

•  Do not attempt to force cables into the incorrect plug ports

CAUTION Risk of minor or moderate injury through unexpected movement

Exceeding the static or dynamic load limits of the Table System may cause unexpected 

operation. This may lead to minor or moderate injury.

•  Do not exceed load limits

CAUTION Risk of minor or moderate injury through crushing

If any Hand Control Key becomes stuck while the system is in motion, the system may 

not stop properly. This may lead to minor or moderate injury through crushing. 

•  Disconnect the system immediately if any Hand Control Key becomes stuck

CAUTION Risk of minor or moderate injury through tripping

During the assembly process, you may have to step over Cables. Tripping over Cables 

may lead to minor or moderate injury.

•  Ensure that the assembly area is kept clear of unnecessary obstructions

•  Be careful not to trip over Cables

CAUTION

This appliance can be used by children from 8 years and above and people with reduced 

physical, sensory or mental capabilities or lack of experience and knowledge if they 

have been given supervision or instruction concerning the use of the appliance in a safe 

way and understand the hazards involved. Children must not play with the appliance. 

Cleaning and maintenance by the user must not be performed by children, unless they 

are over 8 years old and supervised.

Содержание SMARTneo-2G

Страница 1: ...MANUAL Document Version 1 0 July 2019 SMARTneo 2G Cascading...

Страница 2: ...rman language version is the original LOGICDATA Electronic Software Entwicklungs GmbH Wirtschaftspark 18 8530 Deutschlandsberg Austria Phone 43 0 3462 51 98 0 Fax 43 0 3462 51 98 1030 Internet http ww...

Страница 3: ...t documentation before connecting the components to form a Cascading System and putting it into operation Required components For detailed instructions see the Required Components subchapter for your...

Страница 4: ...g System with 2 Actuators For detailed instructions see chapter 6 3 5 on page 15 1 2 SA VE 3 4 1 2 SA VE 3 4 Cascading System with 3 Actuators For detailed instructions see chapter 6 6 on page 16 1 2...

Страница 5: ...nstructions see chapter 6 7 on page 17 1 2 SA VE 3 4 1 2 S A V E 3 4 Performing the Reference Drive For detailed instructions see chapter 7 1 on page 18 O73 Factory Reset For detailed instructions see...

Страница 6: ...5 Explanation of symbols and signal words 10 3 6 Liability 10 3 7 Residual risks 11 3 8 Skilled Persons 12 3 9 Notes for Resellers 12 4 Scope of delivery 12 5 Product 13 5 1 About Cascading 13 5 2 Ab...

Страница 7: ...the Components 17 7 Operation 18 7 1 Reference Drive 18 7 2 Factory Reset 18 7 2 1 With a Basic Hand Control 18 7 2 2 With a Comfort Hand Control 19 8 Troubleshooting 20 8 1 Lexicon 20 8 2 Possible P...

Страница 8: ...After purchase and full payment of the product all text and images in Chapter 3 Safety may be used free of charge by the customer for 10 years after delivery They should be used to prepare end user d...

Страница 9: ...is a Control Box for electrically Height Adjustable Tables It is intended for indoor use only The system may only be installed in compatible Height Adjustable Tables and with LOGICDATA approved acces...

Страница 10: ...r sources INFO Indicates important tips for handling the product 3 6 LIABILITY LOGICDATA products comply with all currently applicable health and safety regulations However risk can result from incorr...

Страница 11: ...ks While cleaning or using the system liquid intrusion may lead to serious injury through electric shocks Do not allow any components to become wet during cleaning Ensure components are placed away fr...

Страница 12: ...l in their native EU official language INFO The Charter of the French Language La charte de la langue fran aise or Bill 101 Loi 101 guarantees the right of the population of Quebec to conduct business...

Страница 13: ...also dependent on parameterization NOTICE This Cascading Manual is only valid for the SMARTneo 2G 2nd generation Consult your product s Datasheet and Type Plate to ensure this is the correct Manual f...

Страница 14: ...risk of death or serious injury through electric shocks Using damaged products may lead to death or serious injury through electric shocks Do not operate the Cascading System if you see housings or c...

Страница 15: ...n each system 1 LOG CBL SMARTneo SYNC 1000 Sync Cable 2 Power Cables 6 5 2 CONNECTING THE COMPONENTS 1 Connect the first Actuator to a Control Box M1 2 Connect the second Actuator to the second Contro...

Страница 16: ...h system 1 LOG CBL SMARTneo SYNC 1000 Sync Cable 2 Power Cables 6 6 2 CONNECTING THE COMPONENTS 1 Connect the first two Actuators to a Control Box M1 and M2 2 Connect the third Actuator to the second...

Страница 17: ...LOG CBL SMARTneo SYNC 1000 Sync Cable 2 Power Cables 6 7 2 CONNECTING THE COMPONENTS 1 Connect the first two Actuators to a Control Box M1 and M2 2 Connect the third and fourth Actuators to the secon...

Страница 18: ...erence Drive must be performed after the Cascading System has been connected for the first time Ensure that all components are connected correctly Press and hold the DOWN Key The Actuators start up at...

Страница 19: ...settings It is now in the same state as it was during the first start up INFO Resetting the Master Control Box in the system to factory settings will automatically reset the Slave Control Box INFO If...

Страница 20: ...r 8 2 POSSIBLE PROBLEMS AND THEIR SOLUTIONS Error code malfunction Possible cause Solution E7O Actuator configuration has been changed Disconnect the Control Boxes from the power supply for approx 30...

Страница 21: ...tor from the Control Box 2 Connect the new Actuator to the Control Box 3 Perform a Reference Drive see chapter 7 1 9 1 3 UNGROUPING A CASCADING SYSTEM 1 Reset the Control Boxes to factory settings see...

Страница 22: ...rk 18 8530 Deutschlandsberg Austria Phone 43 0 3462 5198 0 Fax 43 0 3462 5198 1030 Email office at logicdata net Internet http www logicdata net LOGICDATA North America Inc 1525 Gezon Parkway SW Suite...