background image

22 //ADJUSTABLE BED FRAME - OWNER’S MANUAL

ACTIVATING THE CHILD LOCK

Always activate the Child Lock when children are near the Bed Frame. Proceed as follows:

1. Press and hold the 

Head UP and Foot UP 

Buttons for at least 6 seconds.

2. 7KH/('ZLOOÀDVKWLPHVWRFRQ¿UP7HVWWKH5HPRWH&RQWUROWRFKHFNWKDW

Child Lock has been activated.

To disable Child Lock, repeat the steps above.
If you remove the batteries from the Remote Control, the Child Lock will be deactivated 
automatically.
,I\RXWU\WRRSHUDWHWKH%HG)UDPHZKLOHWKH&KLOG/RFNLVDFWLYDWHGWKH/('ZLOOÀDVK
6 times.

MOVING THE BED FRAME TO A SAVED MEMORY POSITION

Proceed as follows to move the Bed Frame to a saved Memory Position:

1. Press the Memory Position Button for the Memory Position you wish to

move to, then release.

2. Wait for the Bed Frame to move to the saved Memory Position

MOVING THE BED FRAME TO THE SLEEPING POSITION

3. 

The Sleeping Position is the Bed Frame’s lowest position. While in the Sleeping Position, all 
Platforms are horizontal. Proceed as follows to move the Bed Frame to the Sleeping Position:

1. Press and release the Sleeping Position Button (do not hold the Button)
2. Wait for the Bed Frame to move to the Sleeping Position

FACTORY RESET

$)DFWRU\5HVHWUHVWRUHVWKH%HG)UDPHWRWKHVDPHVWDWHDVEHIRUH¿UVWXVH$Q\PHPRU\SR-
sitions you have stored will be deleted and replaced with the pre-set memory positions. To per-
form a Factory Reset:

1. Press and hold the Foot DOWN and Head DOWN buttons for 10 seconds.
2. When the reset is complete, the Control Box will click twice.
3. Release the buttons.

To perform a Reference Drive after the Factory Reset, only release one of the DOWN buttons. 

This will start the Drive automatically.

23

ADJUSTABLE BED FRAME -  OWNER’S MANUAL //

IMPORTANT

Sync Mode allows you to control two Bed Frames with one Remote Control. If you only have 
one Bed Frame continue reading at the next chapter. 

SYNC MODE

%HIRUHFRQ¿JXULQJ6\QF0RGHSOHDVHHQVXUH

 

ƒ

Both Bed Frames are standing next to each other

 

ƒ

The Bed Frames will not collide with each other when moving

 

ƒ

Each Bed Frame can be controlled using its own Remote Control

MOVING THE BED FRAME UP AND DOWN IN SNYC MODE

When Sync Mode is activated, pressing the UP and DOWN Buttons on ei-
ther of the Remote Controls will move both Bed Frames simultaneously.

FIXING MISALIGNMENT

To activate Sync Mode:

1.  Ensure both Bed Frames have been disconnected from the Power Outlet.
2.  Connect the Control Boxes of the two Frames with the Sync Cable (X). This should be in-

serted into the port marked "CAS" on each Control Box. 

3.  Ensure the Cable is Routed so that it does not interfere with the movement of the Bed Frames.
4.  Reconnect the Bed Frames to the Power Outlet.

 

ƒ

If the Bed Frames do not move together, disconnect from the Power and repeat the steps.

 

ƒ

To end Sync Mode, disconnect the Sync Cable.

,IWZRFRQQHFWHG%HG)UDPHVKDYHGLႇHUHQWVDYHG0HPRU\3RVLWLRQVSUHVVLQJD0HPRU\3R-
VLWLRQ%XWWRQZLOOFDXVHWKH%HG)UDPHVWRPRYHWRGLႇHUHQWSRVLWLRQV7KLVLVFDOOHG0LVDOLJQ-
ment. In this case, you must move both Bed Frames to their lowest position. 

1.  Press the Sleeping Position Button on one Remote Control
2.  Wait for both Bed Frames to reach their lowest position
3.  The Bed Frames are realigned. Continue using the Bed Frame as normal.

PERFORMING A FLAT POSITION RESET

To perform a Flat Position Reset: 

1.  Press the Sleeping Position Button for at least 10 seconds.
2.  7KH&RQWURO%R[FOLFNVWZLFHWRFRQ¿UPtheinput.
3.  Perfom a Reference Drive with the Sleeping Position Button or any UP/

DOWN Button (see section "Reference Drive"). 

24 //ADJUSTABLE BED FRAME - OWNER’S MANUAL

DISASSEMBLY

7RGLVDVVHPEOHWKH$GMXVWDEOH%HG)UDPH\RXPXVW¿UVWGLVFRQQHFWWKH%HG)UDPHIURPWKH
mains. Then, follow the assembly instructions in reverse order. To minimize the risk of pinching 
when transporting the Side Rails, secure all moving parts with packaging tape.  

6. DISASSEMBLY AND 

TRANSPORTATION

TRANSPORTATION

After it has been fully assembled, the Bed Frame should only be moved short distances within 
the same room. Lifting the Bed Frame requires two people. To lift the Bed Frame:

1.  (QVXUHWKDWWKH%HG)UDPHKDV¿UVWEHHQPRYHGWRWKH6OHHSLQJ3RVLWLRQ
2.  Stand at opposite sides of the Bed Frame (long sides) and grip the Base Platform. 

NOTICE

 

Moving the Bed Frame on its side or upside down may lead to damage to the product. 
•  Only move the Bed Frame while it is in horizontal position (Platforms facing upwards)
•  'LVDVVHPEOHWKH%HG)UDPHEHIRUHPRYLQJLWWRDGLႇHUHQWORFDWLRQ

CAUTION

 

Risk of minor or moderate injury through crushing

Tilting the Bed Frame when lifting or moving the Adjustable Bed Frame may lead to minor or 
moderate injury through crushing.
•  Keep the Bed Frame level while lifting or moving it
•  Do not attempt to lift or move the Bed Frame alone

Содержание COSMO Austin

Страница 1: ...Document Version 6 July 2021 OWNER S MANUAL ADJUSTABLE BED FRAME...

Страница 2: ...or reproduce the document are reserved No part of this manual may be reproduced mechanically electronically or by other means in any form without prior written permission of LOGICDATA Electronic Softw...

Страница 3: ...imals are in the proximity of the Bed Frame when operating it Ensure nothing obstructs the Bed Frame s range of motion e g night stands or open windows Do not sit directly on any Platform when operati...

Страница 4: ...r Platforms at any time Exceeding the recommended maximum load could damage the product and void the warranty Usage outside of the intended use described in this Owner s Manual is only allowed with wr...

Страница 5: ...WARNING The signal word WARNING indicates a hazardous situation which if not avoided could result in death or serious injury NOTICE The signal word NOTICE indicates a situation that will not lead to...

Страница 6: ...ommended by the manufacturer Never operate the Bed Frame if it or any parts have a damaged Cable or Plug are not work ing properly have been dropped or damaged or dropped into water Return the bed for...

Страница 7: ...ospheres Operating the Adjustable Bed Frame in potentially explosive atmospheres may lead to death or serious injury through explosions Read the relevant directives to determine whether an atmosphere...

Страница 8: ...at all times Product documentation consists of this Owner s Manual and any other relevant documents supplied by the manufacturer Documenta tion must always be kept complete and legible 2 INTRODUCTION...

Страница 9: ...ld result in the prod uct exceeding the RF exposure requirements This may void your authority to use the product SERVICING OF DOUBLE INSULATED PRODUCTS In a double insulated product two systems of ins...

Страница 10: ...e all the parts are present and in perfect condition If any part is damaged or missing FRQWDFW 2 7 RX FDQ QG WKH UHOHYDQW FRQWDFW GHWDLOV DW WKH EHJLQQLQJ RI WKH 2ZQHU V 0DQXDO QVXUH WKDW WKH ER HV DU...

Страница 11: ...OWNER S MANUAL QUICK START GUIDE OWNER S MANUAL REMOTE CONTROL 2x AAA BATTERIES HEAD PLATFORM BASE PLATFORM F H 16X PLATFORM SCREW O N RETAINER BAR L INNER PLATFORM M FOOT PLATFORM HEAD BASE INNER FOO...

Страница 12: ...e product NOTICE QVXUH DOO SDUWV DUH DW URRP WHPSHUDWXUH 3DUWV WKDW DUH WRR FROG RU KRW PD D HFW DVVHPEO CAUTION Risk of minor or moderate injury through cutting Contact with sharp edges may lead to m...

Страница 13: ...DO NOT REMOVE STRAPPING TAPE USE LABELS ON SIDE RAILS DO NOT REMOVE PROTECTIVE MATERIAL STEP 1 PREPARING THE OUTER FRAME WALL Lay the Crossbars D and Side Rails A B on the ground as shown in the pictu...

Страница 14: ...e Knob counter clockwise until it is hand tight D E REMOVE STRAPPING TAPE REMOVE PROTECTIVE MATERIAL CAUTION Risk of minor or moderate injury through crushing The Side Rails are not secured while they...

Страница 15: ...e injury through crushing While screwing in the Crossbar Knobs you will need to lift the moving parts of the Side Rails Allowing these parts to fall may lead to minor or moderate injury through crushi...

Страница 16: ...Platform Screws N WR WKH 3ODWIRUP E KDQG Turn each screw until it is hand tight H A B N STEP 5 MOUNTING THE BASE PLATFORM 1 Lay the Base Platform H upside down across the Bed Frame The Net should fac...

Страница 17: ...ide Rails on either side of the Base Platform 2 Lay the Head and Foot Platforms F M in po sition on the Side Rails 3 8VH WKH QDO 3ODWIRUP screws N to attach the Head and Foot Plat forms to the Side Ra...

Страница 18: ...OTICE Stretching the Power Cable may damage it This may lead to malfunctions with the Bed Frame 1 Connect the Power Cable from the Control Box to the cable of the Power Converter J 2 Connect the secon...

Страница 19: ...INSERTING THE BATTERIES NOTICE Replace the batteries in the Remote Control once a year Do not use rechargeable batteries Insert two 1 5V AAA batteries into the Re mote Control and slide the cover into...

Страница 20: ...with your product may vary NOTICE Pressing too many Buttons in a short space of time can cause damage to the system DLW RQH VHFRQG EHWZHHQ SUHVVLQJ GL HUHQW XWWRQV CAUTION Risk of minor or moderate i...

Страница 21: ...fore operation Ensure the Bed Frame has been unplugged for at least 10 seconds then proceed as follows 1 Plug the Bed Frame into the mains This will automatically switch it to Pairing Mode for 30 minu...

Страница 22: ...o move to then release 2 Wait for the Bed Frame to move to the saved Memory Position MOVING THE BED FRAME TO THE SLEEPING POSITION 3 The Sleeping Position is the Bed Frame s lowest position While in t...

Страница 23: ...ed CAS on each Control Box 3 Ensure the Cable is Routed so that it does not interfere with the movement of the Bed Frames 4 Reconnect the Bed Frames to the Power Outlet If the Bed Frames do not move t...

Страница 24: ...le To lift the Bed Frame 1 QVXUH WKDW WKH HG UDPH KDV UVW EHHQ PRYHG WR WKH 6OHHSLQJ 3RVLWLRQ 2 Stand at opposite sides of the Bed Frame long sides and grip the Base Platform NOTICE Moving the Bed Fra...

Страница 25: ...LQJ WHFKQLFDO GL FXOWLHV FRQWDFW 2 7 XVLQJ WKH GHWDLOV RQ SDJH 7 CLEANING AND MAINTENANCE WARNING Moderate risk of death or serious injury through electric shocks Leaving the Bed Frame plugged in whil...

Страница 26: ...oes out then plug it back in 4 Replace the batteries in the Remote Control If power cannot be restored an Emergency Lowering is required Proceed as follows 1 Unplug the Power Converter from the power...

Страница 27: ...You will need to perform separate Emergency Lowerings for Bed Frames con nected by the Sync Cable CODE 2 X Click 1 X Click 4 6 X Click DEFINITION Normal operation Continue to operate the Bed Frame The...

Страница 28: ...product should not be disposed of with regular household waste Adhere to the disposal procedures for the raw materials and components used Recycle as many parts as possible Careless or incorrect dispo...

Отзывы: