background image

13

ADJUSTABLE BED FRAME -  OWNER’S MANUAL //

STEP 2: ATTACHING THE LEGS

1. 3RVLWLRQWKH¿UVW/HJ

(C)

 below

the Side Rail (

A/B

) as shown in

the picture.

2. Turn the Leg to screw it into

the Side Rail. It should be hand

tight.

3. Repeat Steps 1 and 2 to Screw

in the other 3 Legs.

A B

C

HEA

D

FOO

T

DO NOT REMOVE STRAPPING TAPE

USE LABELS ON SIDE RAILS

DO NOT REMOVE PROTECTIVE MATERIAL 

STEP 1: PREPARING THE OUTER FRAME

WAL

L

Lay the Crossbars

 (D) 

and Side Rails

 (A, 

B) 

on the ground, as shown in the picture.

IMPORTANT:

• Ensure the Crossbars are parallel

and roughly 5 feet (150 cm) apart.

• Use the labels on the Side Rails to

ensure they are oriented correctly.

• Use the Crossbars to determine

the position of the Side Rails. The

Side Rails should be the width of the

Crossbar apart.

D

B

A

14 //ADJUSTABLE BED FRAME - OWNER’S MANUAL

STEP 3: CONNECTING THE BARS

1.  /LIWWKH¿UVW&URVVEDU

(D)

 

and place one end of it 

into a slot on the Side Rail 

(Right)

 (A).

 

Ensure the Thread on the 

Side Rail (the metal part 

facing upwards) passes 

through the hole at the 

end of the Crossbar.

2.  Place a Crossbar Knob (E) 

onto the thread connect-

ing the Side Rail and the 

Crossbar. Turn the Knob 

counter-clockwise until it 

is hand tight. 

D

E

REMOVE STRAPPING TAPE

REMOVE PROTECTIVE MATERIAL

CAUTION

 

Risk of minor or moderate injury through crushing

 

The Side Rails are not secured while they are standing alone. If they fall over, this may lead to 
minor or moderate injury through crushing.
•  Do not attempt to stand the Side Rails upright before they are connected to the Crossbars
•  Be careful not to knock over the Side Rails
•  Ensure that you are wearing suitable footwear while assembling the Bed Frame

3.  Repeat steps 1 and 2 for 

the second Crossbar.

D

A

15

ADJUSTABLE BED FRAME -  OWNER’S MANUAL //

STEP 4: CONNECTING THE CABLES

1. Insert the 4 Motor Cables

from the Side Rails 

(A, B) 

into

the Plug Ports on the Control

Box 

(I)

. Ensure that the color

of the Plug matches the color 

of the Plug Port.

2. Insert the Power Converter

Cable

 (J) 

into the Control

%R[/D\WKH&DEOHÀDWDORQJ

WKHÀRRUWRUHGXFHWKHULVNRI

tripping.

CAUTION

Risk of minor or moderate injury through crushing 

While screwing in the Crossbar Knobs, you will need to lift the moving parts of the Side Rails. 
Allowing these parts to fall may lead to minor or moderate injury through crushing.
• Ensure moving parts do not fall down during assembly

CAUTION

Risk of minor or moderate injury through crushing

 

*ULSSLQJWKH6LGH5DLOVPRYLQJSDUWVPD\OHDGWRPLQRURUPRGHUDWHLQMXU\WKURXJKFUXVKLQJ
• 'RQRWWRXFKPRYLQJSDUWVZKHQOLIWLQJRUPRYLQJWKH6LGH5DLOV2QO\JULSWKH¿[HGSDUWV

A

B

J

I

4. Connect the Crossbars 

(D)

to the Side Rail (Left) 

(B)

as shown in steps 1-3.

D

D

B

A

R

Содержание COSMO Austin

Страница 1: ...Document Version 6 July 2021 OWNER S MANUAL ADJUSTABLE BED FRAME...

Страница 2: ...or reproduce the document are reserved No part of this manual may be reproduced mechanically electronically or by other means in any form without prior written permission of LOGICDATA Electronic Softw...

Страница 3: ...imals are in the proximity of the Bed Frame when operating it Ensure nothing obstructs the Bed Frame s range of motion e g night stands or open windows Do not sit directly on any Platform when operati...

Страница 4: ...r Platforms at any time Exceeding the recommended maximum load could damage the product and void the warranty Usage outside of the intended use described in this Owner s Manual is only allowed with wr...

Страница 5: ...WARNING The signal word WARNING indicates a hazardous situation which if not avoided could result in death or serious injury NOTICE The signal word NOTICE indicates a situation that will not lead to...

Страница 6: ...ommended by the manufacturer Never operate the Bed Frame if it or any parts have a damaged Cable or Plug are not work ing properly have been dropped or damaged or dropped into water Return the bed for...

Страница 7: ...ospheres Operating the Adjustable Bed Frame in potentially explosive atmospheres may lead to death or serious injury through explosions Read the relevant directives to determine whether an atmosphere...

Страница 8: ...at all times Product documentation consists of this Owner s Manual and any other relevant documents supplied by the manufacturer Documenta tion must always be kept complete and legible 2 INTRODUCTION...

Страница 9: ...ld result in the prod uct exceeding the RF exposure requirements This may void your authority to use the product SERVICING OF DOUBLE INSULATED PRODUCTS In a double insulated product two systems of ins...

Страница 10: ...e all the parts are present and in perfect condition If any part is damaged or missing FRQWDFW 2 7 RX FDQ QG WKH UHOHYDQW FRQWDFW GHWDLOV DW WKH EHJLQQLQJ RI WKH 2ZQHU V 0DQXDO QVXUH WKDW WKH ER HV DU...

Страница 11: ...OWNER S MANUAL QUICK START GUIDE OWNER S MANUAL REMOTE CONTROL 2x AAA BATTERIES HEAD PLATFORM BASE PLATFORM F H 16X PLATFORM SCREW O N RETAINER BAR L INNER PLATFORM M FOOT PLATFORM HEAD BASE INNER FOO...

Страница 12: ...e product NOTICE QVXUH DOO SDUWV DUH DW URRP WHPSHUDWXUH 3DUWV WKDW DUH WRR FROG RU KRW PD D HFW DVVHPEO CAUTION Risk of minor or moderate injury through cutting Contact with sharp edges may lead to m...

Страница 13: ...DO NOT REMOVE STRAPPING TAPE USE LABELS ON SIDE RAILS DO NOT REMOVE PROTECTIVE MATERIAL STEP 1 PREPARING THE OUTER FRAME WALL Lay the Crossbars D and Side Rails A B on the ground as shown in the pictu...

Страница 14: ...e Knob counter clockwise until it is hand tight D E REMOVE STRAPPING TAPE REMOVE PROTECTIVE MATERIAL CAUTION Risk of minor or moderate injury through crushing The Side Rails are not secured while they...

Страница 15: ...e injury through crushing While screwing in the Crossbar Knobs you will need to lift the moving parts of the Side Rails Allowing these parts to fall may lead to minor or moderate injury through crushi...

Страница 16: ...Platform Screws N WR WKH 3ODWIRUP E KDQG Turn each screw until it is hand tight H A B N STEP 5 MOUNTING THE BASE PLATFORM 1 Lay the Base Platform H upside down across the Bed Frame The Net should fac...

Страница 17: ...ide Rails on either side of the Base Platform 2 Lay the Head and Foot Platforms F M in po sition on the Side Rails 3 8VH WKH QDO 3ODWIRUP screws N to attach the Head and Foot Plat forms to the Side Ra...

Страница 18: ...OTICE Stretching the Power Cable may damage it This may lead to malfunctions with the Bed Frame 1 Connect the Power Cable from the Control Box to the cable of the Power Converter J 2 Connect the secon...

Страница 19: ...INSERTING THE BATTERIES NOTICE Replace the batteries in the Remote Control once a year Do not use rechargeable batteries Insert two 1 5V AAA batteries into the Re mote Control and slide the cover into...

Страница 20: ...with your product may vary NOTICE Pressing too many Buttons in a short space of time can cause damage to the system DLW RQH VHFRQG EHWZHHQ SUHVVLQJ GL HUHQW XWWRQV CAUTION Risk of minor or moderate i...

Страница 21: ...fore operation Ensure the Bed Frame has been unplugged for at least 10 seconds then proceed as follows 1 Plug the Bed Frame into the mains This will automatically switch it to Pairing Mode for 30 minu...

Страница 22: ...o move to then release 2 Wait for the Bed Frame to move to the saved Memory Position MOVING THE BED FRAME TO THE SLEEPING POSITION 3 The Sleeping Position is the Bed Frame s lowest position While in t...

Страница 23: ...ed CAS on each Control Box 3 Ensure the Cable is Routed so that it does not interfere with the movement of the Bed Frames 4 Reconnect the Bed Frames to the Power Outlet If the Bed Frames do not move t...

Страница 24: ...le To lift the Bed Frame 1 QVXUH WKDW WKH HG UDPH KDV UVW EHHQ PRYHG WR WKH 6OHHSLQJ 3RVLWLRQ 2 Stand at opposite sides of the Bed Frame long sides and grip the Base Platform NOTICE Moving the Bed Fra...

Страница 25: ...LQJ WHFKQLFDO GL FXOWLHV FRQWDFW 2 7 XVLQJ WKH GHWDLOV RQ SDJH 7 CLEANING AND MAINTENANCE WARNING Moderate risk of death or serious injury through electric shocks Leaving the Bed Frame plugged in whil...

Страница 26: ...oes out then plug it back in 4 Replace the batteries in the Remote Control If power cannot be restored an Emergency Lowering is required Proceed as follows 1 Unplug the Power Converter from the power...

Страница 27: ...You will need to perform separate Emergency Lowerings for Bed Frames con nected by the Sync Cable CODE 2 X Click 1 X Click 4 6 X Click DEFINITION Normal operation Continue to operate the Bed Frame The...

Страница 28: ...product should not be disposed of with regular household waste Adhere to the disposal procedures for the raw materials and components used Recycle as many parts as possible Careless or incorrect dispo...

Отзывы: