73
Key loc
Holding the key lock sensor
down turns the key lock function on or off. If the pilot light
associated with the
key lock sensor is on, the keypad is locked.
The locking function can be activated when the cooking levels are activated or when the cook
top is off. If the cook top is on, the key lock function locks all the sensors except the general
on/off sensor and the key lock. When the cook top is off, the key lock function locks all the
sensors, including the general on/off, except the key lock.
Unlocking the keypad
If the keypad is locked (the pilot light associated with the key lock sensor is on), holding down
the key lock
Sensor
turns the key lock function off and the pilot light goes off.
Residual heat for radiant heaters
While a temperature on the cook top glass surface is above 65ºC, this condition will be shown in
the
associated display, by means of an “H”.
If the cook top is switched off, the residual heat is shown by a static “H” in the display. If the
cook top is on, but the power level is 0, the associated display will show alternately “H” and “0”.
Operating the timer
The timer is activated by pressing the timer keys (+) or (-) up to the big central symbol
. The
timer value can be selected between 1 and 99
minutes, and can be modified at any time.
To cancel the operation of the timer, select a timer value of <00> using the sensor (-), or switch
off the timer by
pressing the corresponding sensors (+) and (-) at the same time.
Heater on timer
This can be any of the touch-control heaters. When the timer value runs out, the heater
associated with the timer switches off.
The heater associated with the timer can be can be selected.
Selectable heater
The user can select the heater on which the timer function is to operate. The
selection of a new heater disables the previous selection in such a way that the timer only
operates on
one heater each time.
The heater must always be selected before the time is set; otherwise, the timer will switch off.
If we take longer than 10 seconds to select the heater, the timer will switch off.
If, after selecting the heater, the time is not defined (T=00) in 10 sec., the timer switches off.
It is possible for the user to time a heater at power 0 .
If the configuration permits Alarm-mode , instead select a heater , the user touches again the
timer in the heater selection periode, it goes to minute-minder mode and at the end of time will
not switch-off any heater.
In Alarm-mode, the dot of the timer display doesn’t light.
Indication of the heater on timer with “t” on the heater display.