background image

8 Replacement Parts and Accessories

Description

Loctite Item No.

10 ml Clear Syringe Package

97207

30 ml Clear Syringe Package

97244

10 ml Air Line Adapters

97208

30 ml Air Line Adapters

97245

Foot Switch

97201

Filter Regulator

985397

9 Warranty

WARRANTY

Henkel expressly warrants that all products referred to in this Instruction Manual for (1514629) Henkel SD10 Digital
Syringe Dispenser) (hereafter called "Products") shall be free from defects in materials and workmanship.
Liability for Henkel shall be limited, as its option, to replacing those Products which are shown to be
defective in either materials or workmanship or to credit the purchaser the amount of the purchase price
thereof (plus freight and insurance charges paid therefor by the user). The purchaser’s sole and exclusive
remedy for breach of warranty shall be such replacement or credit.

A claim of defect in materials or workmanship in any Products shall be allowed only when it is submitted
in writing within one month after discovery of the defect or after the time the defect should reasonably
have been discovered and in any event, within (12) months after the delivery of the Products to the
purchaser. This warranty does not apply to perishable items, such as (indicate items: fuses, filters, lights,
etc.). No such claim shall be allowed in respect of products which have been neglected or improperly
stored, transported, handled, installed, connected, operated, used or maintained. In the event of
unauthorized modification of the Products including, where products, parts or attachments for use in
connection with the Products are available from Henkel, the use of products, parts or attachments which
are not manufactured by Henkel, no claim shall be allowed.

No Products shall be returned to Henkel for any reason without prior written approval from Henkel.
Products shall be returned freight prepaid, in accordance with instructions from Henkel.

NO WARRANTY IS EXTENDED TO ANY EQUIPMENT WHICH HAS BEEN ALTERED, MISUSED,
NEGLECTED, OR DAMAGED BY ACCIDENT.

EXCEPT FOR THE EXPRESS WARRANTY CONTAINED IN THIS SECTION, HENKEL MAKES NO
WARRANTY OF ANY KIND WHATSOEVER, EXPRESS OR IMPLIED, WITH RESPECT TO THE
PRODUCTS.

ALL WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND OTHER
WARRANTIES OF WHATEVER KIND (INCLUDING AGAINST PATENT OR TRADEMARK INFRINGEMENT)
ARE HEREBY DISCLAIMED BY HENKEL AND WAIVED BY THE PURCHASER.

THIS SECTION SETS FORTH EXCLUSIVELY ALL OF LIABILITY FOR HENKEL TO THE PURCHASER IN
CONTRACT, IN TORT OR OTHERWISE IN THE EVENT OF DEFECTIVE PRODUCTS.

WITHOUT LIMITATION OF THE FOREGOING, TO THE FULLEST EXTENT POSSIBLE UNDER
APPLICABLE LAWS, HENKEL EXPRESSLY DISCLAIMS ANY LIABILITY WHATSOEVER FOR ANY
DAMAGES INCURRED DIRECTLY OR INDIRECTLY IN CONNECTION WITH THE SALE OR USE OF, OR
OTHERWISE IN CONNECTION WITH, THE PRODUCTS, INCLUDING, WITHOUT LIMITATION, LOSS OF
PROFITS AND SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES, WHETHER CAUSED BY
NEGLIGENCE FROM HENKEL OR OTHERWISE.

Содержание SD10

Страница 1: ...EQUIPMENT Operation Manual Vacuum Pressure psi psi SHOT SET EXIT TEACH PROGRAM CYCLE TIMER MANUAL DISPENSE MODE SD10 Digital Syringe Dispenser Loctite SD10 Digital Syringe Dispenser Part Number 1514629 ...

Страница 2: ...ents 7 3 1 1 Electrical 7 3 1 2 Pneumatics 7 3 2 Connections and Dimensions 7 3 3 Other Data 7 4 Installations 8 4 1 Environmental Conditions 8 4 2 Placement 8 5 Dispensing 8 5 1 Filling the Syringe 8 5 2 Set Up 9 5 2 1 Purging Air from the Syringe 9 5 2 2 Manual Mode 9 5 2 3 Programs 10 5 2 4 Timer mode 10 5 2 5 Cycle Mode 11 6 Cares and Maintenance 12 6 1 Care 12 6 2 Maintenance 12 7 Troubleshoo...

Страница 3: ...handling of the unit during operation or adjustment as well as for service activities The numbers printed in bold in the text xx refer to the corresponding position numbers in the illustration in Section 2 2 1 As a result of technical development the illustrations and descriptions in this instruction manual can deviate in detail from the actual unit delivered 1 2 Items Supplied 1 SD10 Digital Syri...

Страница 4: ...ndling of Loctite brand products may be hazardous to ones health Observe general safety regulations for the handling of chemicals Observe manufacturer s instructions Request a safety data sheet for the product used Always wear goggles when operating with pressurized air 1 4 Usage The Loctite SD10 Digital Syringe Dispenser 1514629 is a self contained dispenser system and suitable for the precise ap...

Страница 5: ...r 4 5 3 2 1 Front Panel For Service Spare Parts Repairs USA 1 860 571 5174 Germany 49 89 9268 0 Singapore 65 6266 0100 China 86 21 2891 8547 Visit equipment loctite com Label P N 988341 Rear Panel Air Input Air Exhaust Foot Switch XS 1 Power Input MADE IN TAIWAN 24VDC Output SD10 Digital Syringe Dispenser IDH 1514629 Power Switch 24VDC 0 5mA 9 8 7 6 ...

Страница 6: ...nge barrel and prevents air from permeating the product as well as preventing the product from running back out of the syringe barrel and into the control unit 15 Syringe barrel 16 Luer lock tip cap 17 Dispense needle 2 2 Theory of Operation The Loctite SD10 Digital Syringe Dispenser 1514629 is connected to an external pneumatic supply The control unit of the SD10 Digital Syringe Dispenser regulat...

Страница 7: ...er regulator Accessory Order No 985397 Range of the Pressure regulator 0 00 7 00 bar 0 00 100 psi Pressure indicator 0 00 7 00 bar 0 00 100 psi 3 2 Connections and Dimensions Power connection Cold appliance coupl IEC 320 acc to VDE 0625 Pneumatic hose size External dia 6 mm or 1 4 Dimensions W x H x D 265mm W x 211mm D x 72mm H 10 4 W x 8 3 D x 2 8 H 3 3 Other Data Protection level IP 33 Operating...

Страница 8: ...e vacuum start with the vacuum in the full off position and increase slowly to ensure product is not sucked back into the unit 5 Dispensing 5 1 Filling the Syringe Improper handling of Loctite brand products may be harmful to ones health Observe general safety regulations for the handling of chemicals Observe manufacturer s instructions Request a material safety data sheet for the product used Clo...

Страница 9: ...of bubbles from the dispense needle If the product drips out of the dispense needle Slowly turn the vacuum regulator 4 counter clockwise until the dripping stops Do not continue turning after the dripping has stopped When air is sucked in the syringe must again be purged of air and curing of the product can occur This can also cause the product to be sucked back into the unit and will damage it 5 ...

Страница 10: ... the button and the button to change numbers press the button to move the cursor Press the button to save the data You can set a program number to record dispense and interval time in Timer and Cycle mode The program number can be 00 39 For detailed operation please check chapters 5 2 4 and 5 2 5 5 2 4 Timer mode Select a program number following the setup in section 5 2 3 Press the button until t...

Страница 11: ...e follow the steps below to set the delay between cycles Press the button until the LED above CYCLE is lit Press the button to setup the interval time Press the button and the button to change numbers and the button to move the cursor Press the button to save the setting Or press the button until the light above flashes Press the button or foot switch to set the dispense time Press the button to s...

Страница 12: ...eral safety regulations for the handling of chemicals Observe manufacturer s instructions Request a material safety data sheet for the product used Recommended cleaning agents for Anaerobic UV curing and Chipbonder adhesives There are currently no recommended solvents for removing cured Loctite brand adhesives Fluid adhesive residues can be removed with various solvents ACETONE is well suited for ...

Страница 13: ...ed Connect air pressure hose correctly Syringe 15 is not properly connected Attach syringe 15 correctly Luer lock tip cap 16 is not removed Replace Luer lock tip cap 16 with a dispense needle 17 Dispensing needle 17 is clogged too small or too large Replace dispense needle 17 No product too little or too much product Control unit is defective Contact Henkel Equipment Service Product drips Vacuum r...

Страница 14: ...ansported handled installed connected operated used or maintained In the event of unauthorized modification of the Products including where products parts or attachments for use in connection with the Products are available from Henkel the use of products parts or attachments which are not manufactured by Henkel no claim shall be allowed No Products shall be returned to Henkel for any reason witho...

Страница 15: ...h Drive 03 01 02 Haw Par Technocentre SINGAPORE 149598 Henkel China Company Ltd No 928 Zhang Heng Road Zhangjiang Hi Tech Park Pudong Shanghai China 201203 Henkel Loctite Korea 8F Mapo Tower 418 Mapo dong Mapo gu Seoul 121 734 KOREA Henkel Japan Ltd 27 7 Shin Isogo cho Isogo ku Yokohama 235 0017 JAPAN www equipment loctite com Loctite is a trademark of Henkel Corporation U S A Copyright 2006 Henke...

Отзывы: