background image

TABLE OF CONTENTS

1 Please observe the following

.......................................................................................... 3

1.1 Emphasized sections

............................................................................................ 3

1.2 Items Supplied

....................................................................................................... 3

1.3 For your safety

....................................................................................................... 4

1.4 Usage

...................................................................................................................... 4

2 Description - Typical System Set-Up

........................................................................... 5

2.1 Operating Elements

.............................................................................................. 6

2.2 Theory of Operation

.............................................................................................. 6

3 Technical Data

................................................................................................................ 7

3.1 Energy Requirements

........................................................................................... 7

3.1.1 Electrical

.............................................................................................................. 7

3.1.2 Pneumatics

.......................................................................................................... 7

3.2 Connections and Dimensions

.............................................................................. 7

3.3 Other Data

.............................................................................................................. 7

4 Installations

.................................................................................................................... 8

4.1 Environmental Conditions

.................................................................................... 8

4.2 Placement

............................................................................................................... 8

5 Dispensing

....................................................................................................................... 8

5.1 Filling the Syringe

.................................................................................................. 8

5.2 Set Up

...................................................................................................................... 9

5.2.1 Purging Air from the Syringe

............................................................................ 9

5.2.2 Manual Mode

...................................................................................................... 9

5.2.3 Programs

........................................................................................................... 10

5.2.4 Timer mode

....................................................................................................... 10

5.2.5 Cycle Mode

....................................................................................................... 11

6 Cares and Maintenance

............................................................................................... 12

6.1 Care

....................................................................................................................... 12

6.2 Maintenance

......................................................................................................... 12

7 Troubleshooting

........................................................................................................... 13

8 Replacement Parts and Accessories

........................................................................... 14

9 Warranty

...................................................................................................................... 14

Содержание SD10

Страница 1: ...EQUIPMENT Operation Manual Vacuum Pressure psi psi SHOT SET EXIT TEACH PROGRAM CYCLE TIMER MANUAL DISPENSE MODE SD10 Digital Syringe Dispenser Loctite SD10 Digital Syringe Dispenser Part Number 1514629 ...

Страница 2: ...ents 7 3 1 1 Electrical 7 3 1 2 Pneumatics 7 3 2 Connections and Dimensions 7 3 3 Other Data 7 4 Installations 8 4 1 Environmental Conditions 8 4 2 Placement 8 5 Dispensing 8 5 1 Filling the Syringe 8 5 2 Set Up 9 5 2 1 Purging Air from the Syringe 9 5 2 2 Manual Mode 9 5 2 3 Programs 10 5 2 4 Timer mode 10 5 2 5 Cycle Mode 11 6 Cares and Maintenance 12 6 1 Care 12 6 2 Maintenance 12 7 Troubleshoo...

Страница 3: ...handling of the unit during operation or adjustment as well as for service activities The numbers printed in bold in the text xx refer to the corresponding position numbers in the illustration in Section 2 2 1 As a result of technical development the illustrations and descriptions in this instruction manual can deviate in detail from the actual unit delivered 1 2 Items Supplied 1 SD10 Digital Syri...

Страница 4: ...ndling of Loctite brand products may be hazardous to ones health Observe general safety regulations for the handling of chemicals Observe manufacturer s instructions Request a safety data sheet for the product used Always wear goggles when operating with pressurized air 1 4 Usage The Loctite SD10 Digital Syringe Dispenser 1514629 is a self contained dispenser system and suitable for the precise ap...

Страница 5: ...r 4 5 3 2 1 Front Panel For Service Spare Parts Repairs USA 1 860 571 5174 Germany 49 89 9268 0 Singapore 65 6266 0100 China 86 21 2891 8547 Visit equipment loctite com Label P N 988341 Rear Panel Air Input Air Exhaust Foot Switch XS 1 Power Input MADE IN TAIWAN 24VDC Output SD10 Digital Syringe Dispenser IDH 1514629 Power Switch 24VDC 0 5mA 9 8 7 6 ...

Страница 6: ...nge barrel and prevents air from permeating the product as well as preventing the product from running back out of the syringe barrel and into the control unit 15 Syringe barrel 16 Luer lock tip cap 17 Dispense needle 2 2 Theory of Operation The Loctite SD10 Digital Syringe Dispenser 1514629 is connected to an external pneumatic supply The control unit of the SD10 Digital Syringe Dispenser regulat...

Страница 7: ...er regulator Accessory Order No 985397 Range of the Pressure regulator 0 00 7 00 bar 0 00 100 psi Pressure indicator 0 00 7 00 bar 0 00 100 psi 3 2 Connections and Dimensions Power connection Cold appliance coupl IEC 320 acc to VDE 0625 Pneumatic hose size External dia 6 mm or 1 4 Dimensions W x H x D 265mm W x 211mm D x 72mm H 10 4 W x 8 3 D x 2 8 H 3 3 Other Data Protection level IP 33 Operating...

Страница 8: ...e vacuum start with the vacuum in the full off position and increase slowly to ensure product is not sucked back into the unit 5 Dispensing 5 1 Filling the Syringe Improper handling of Loctite brand products may be harmful to ones health Observe general safety regulations for the handling of chemicals Observe manufacturer s instructions Request a material safety data sheet for the product used Clo...

Страница 9: ...of bubbles from the dispense needle If the product drips out of the dispense needle Slowly turn the vacuum regulator 4 counter clockwise until the dripping stops Do not continue turning after the dripping has stopped When air is sucked in the syringe must again be purged of air and curing of the product can occur This can also cause the product to be sucked back into the unit and will damage it 5 ...

Страница 10: ... the button and the button to change numbers press the button to move the cursor Press the button to save the data You can set a program number to record dispense and interval time in Timer and Cycle mode The program number can be 00 39 For detailed operation please check chapters 5 2 4 and 5 2 5 5 2 4 Timer mode Select a program number following the setup in section 5 2 3 Press the button until t...

Страница 11: ...e follow the steps below to set the delay between cycles Press the button until the LED above CYCLE is lit Press the button to setup the interval time Press the button and the button to change numbers and the button to move the cursor Press the button to save the setting Or press the button until the light above flashes Press the button or foot switch to set the dispense time Press the button to s...

Страница 12: ...eral safety regulations for the handling of chemicals Observe manufacturer s instructions Request a material safety data sheet for the product used Recommended cleaning agents for Anaerobic UV curing and Chipbonder adhesives There are currently no recommended solvents for removing cured Loctite brand adhesives Fluid adhesive residues can be removed with various solvents ACETONE is well suited for ...

Страница 13: ...ed Connect air pressure hose correctly Syringe 15 is not properly connected Attach syringe 15 correctly Luer lock tip cap 16 is not removed Replace Luer lock tip cap 16 with a dispense needle 17 Dispensing needle 17 is clogged too small or too large Replace dispense needle 17 No product too little or too much product Control unit is defective Contact Henkel Equipment Service Product drips Vacuum r...

Страница 14: ...ansported handled installed connected operated used or maintained In the event of unauthorized modification of the Products including where products parts or attachments for use in connection with the Products are available from Henkel the use of products parts or attachments which are not manufactured by Henkel no claim shall be allowed No Products shall be returned to Henkel for any reason witho...

Страница 15: ...h Drive 03 01 02 Haw Par Technocentre SINGAPORE 149598 Henkel China Company Ltd No 928 Zhang Heng Road Zhangjiang Hi Tech Park Pudong Shanghai China 201203 Henkel Loctite Korea 8F Mapo Tower 418 Mapo dong Mapo gu Seoul 121 734 KOREA Henkel Japan Ltd 27 7 Shin Isogo cho Isogo ku Yokohama 235 0017 JAPAN www equipment loctite com Loctite is a trademark of Henkel Corporation U S A Copyright 2006 Henke...

Отзывы: