Chapter 3: Procedures
3-43
HYDROBAR EXPRESS 220
Remnant Check Device (SQ5) Adjustment
The purpose of this procedure is to adjust the SQ5 switch.
Tools List:
•
5mm allen wrench
•
Small jewelers flat-blade screwdriver
Procedure
Conditions:
•
Guiding channel covers open.
•
Main bar feed power on.
Step 1: Loosen the split collar so that the switch can be rotated by hand but not too loose so that the switch will fall down.
nnel, if it
tep 3: Rotate the switch until the red sensing beam is centered on the bar.
Split collar
Step 2: Place a piece of the smallest diameter bar available inside the channels. The bar should lie in the center of the cha
appears to be off center the entire adjustment can be thrown off; move the bar to the center.
S
3mm bar stock
Red sensing beam
Содержание Hydrobar Express 220
Страница 61: ......
Страница 143: ......
Страница 147: ......
Страница 154: ...Chapter 6 Spare Parts Spare Parts 6 7 HYDROBAR EXPRESS 220 Chapter 6 6 7 HYDROBAR EXPRESS 220 Chain Drive Assembly L F ...
Страница 155: ...6 8 Chapter 6 Spare Parts Spare Parts HYDROBAR EXPRESS 220 6 8 Chapter 6 HYDROBAR EXPRESS 220 Chain Drive Assembly R F ...
Страница 156: ...Chapter 6 Spare Parts 6 9 HYDROBAR EXPRESS 220 Servo Motor Assembly ...
Страница 157: ...6 10 Chapter 6 Spare Parts Spare Parts HYDROBAR EXPRESS 220 6 10 Chapter 6 HYDROBAR EXPRESS 220 Remnant Vise ...
Страница 158: ...Chapter 6 Spare Parts Spare Parts 6 11 HYDROBAR EXPRESS 220 Chapter 6 6 11 HYDROBAR EXPRESS 220 Sensor Support Assembly ...
Страница 161: ...6 14 Chapter 6 Spare Parts HYDROBAR EXPRESS 220 Hydraulic Pump Assembly ...
Страница 162: ...Chapter 6 Spare Parts Spare Parts 6 15 HYDROBAR EXPRESS 220 Chapter 6 6 15 HYDROBAR EXPRESS 220 Coding Disc Assembly ...
Страница 163: ...6 16 Chapter 6 Spare Parts HYDROBAR EXPRESS 220 Diameter Adjustment Motor Assembly ...
Страница 164: ...Chapter 6 Spare Parts 6 17 HYDROBAR EXPRESS 220 Air Regulator and Cable Passage Plate ...