Z8F3224 ZMOTION Development Kit
UM029501-0321
SAMPLE APPLICATIONS
User Manual
13
The MCU normally stays in Stop mode to conserve power. Each time it wakes up, a status
message is sent to indicate the reason for the wake up. Table 7 lists these status message
descriptions.
Note:
In Table 7,
‘*’ indicates MCU wake up and ‘.’ indicates MCU returning to Stop mode. When
Motion Detected status is sent, an ASCII BELL character (0x07) is also sent. Some terminal
applications can interpret this and provide an audible indication of motion detection
Status Code
Description
*0004
Wake up from Power-on Stability Delay timer.
*0002
Wake up from Ignore Motion Timer
*0001
Wake up due to analog PIR motion event
*0010
Wake up to drive Motion Trigger Output inactive
PIR Stable
PIR sensor is stable
– Power on stability delay complete.
Motion Detected
The ZMOTION Engine validated the motion event.
EM
Motion detection enabled
– Ignore Motion time is complete
SW1 Pressed
Indicates that Tamper1/SW1 is pressed down
SW1 Released
Indicates that Tamper1/SW1 is pressed to release the switch up
SW2 Pressed
Indicates that Tamper2/SW2 is pressed down
SW2 Released
Indicates that Tamper2/SW2 is pressed to release the switch up
.
MCU has entered Sleep mode
Table 7. Status Messages
Figure 8. ZM_LP_Basic Power on Messages