background image

Operating instructions  T80PL 2010                               20/21                                         (01/2010)

6.               

In the event of a malfunction

Malfunction

Possible cause

Remedial action

Lift does

Is the key on the control unit

Set the key switches correctly

not function

at -I- and are the others at

(see 4.5 or 4.6)

at all

-0- or removed?

Are all EMERGENCY STOP

Unlock the EMERGENCY STOP

buttons unlocked?

buttons by turning or pulling
(depending on version)

Is the main switch for the lift

Turn on the main switch

at -I- ?

(see 4.1)

Safety arrester has triggered

Inform technical personnel

Lift does not

Are the safety barriers in the

Actuate the safety barriers again,

start when the

horizontal position?

if necessary move them slightly

platform is

upwards or downwards

open and

Are the drive-on ramps and the

Push the drive-on ramps and

occupied

 safety plate (if fitted) freely

 safety plate slightly to the outside.

movable?

Drive in the opposite direction.

Automatic

Are all key switches set to

Set the key switches correctly

only:

-0- except at the operating

(see 4.5 or 4.6)

Lift does not

station chosen by you?

fold

In the case of wireless operating Replace the transmitter batteries

automatically

stations: are the transmitter
batteries OK?

If you cannot repair the error yourself in this way, please inform your customer service.

7.

Acoustic warning signals

Duration

[sec]

Pause

[sec]

Reason

Remedial action

0.1

5.0

Low battery voltage

(see also 4.4)

Drive to the charging station and 
charge the batteries

0.1

0.5

Acoustic drive warning

(see also 5.5)

     -----

2x short

4.0

Overtemperature of 
motor/electronics, or defective fuse

It is possible to resume driving after a 
cooling down period of approx. 5 min. 
(If cooling is insufficient, the cooling 
period is extended by a further 5 min.)

3x short

4.0

Faulty electronics/motor

Inform customer service

Continuous 
tone

  ----

Emergency call by means of 
beeper on the platform, or 
overloading

Release the emergency call button.
Shift centre of gravity towards the rail 
or reduce the weight

Note: The acoustic warning signal can be suppressed by pressing the emergency stop button; the 
charging procedure is retained.

Содержание T80

Страница 1: ...4 6 Travelling with the platform lift 14 4 7 What to do in the event of an unexpected standstill 15 4 7 1 Hand wheel operation metal hood 15 4 7 2 Evacuation metal hood 15 4 7 3 Hand wheel operation plastic hood 17 4 7 4 Evacuation plastic hood 18 5 Options extras 19 5 1 Folding seat 19 5 2 Emergency call 19 5 3 Lateral drive on ramp 19 5 4 Acoustic visual signal 19 6 In the event of a malfunction...

Страница 2: ...MC directive 2004 108 EU Low voltage directive 2006 95 EU The following harmonised standards were applied respectively their protection target fulfilled EN 81 40 2009 EN 349 2008 EN ISO 12100 1 2004 EN ISO 12100 2 2004 EN ISO 13850 2007 EN ISO 13857 2008 EN ISO 14121 1 2008 EN 60204 1 2007 The following notified body TÜV AUSTRIA SERVICES GMBH IDF no 0408 was employed for EU type testing test repor...

Страница 3: ... Dead weight of the platform Loading capacity of the platform Serial number Year of manufacture Type description Type of machine General The rating plate provides the most important information about the platform lift Field for details of the importer dealer 1 ...

Страница 4: ... with many sensitive surfaces Here is an overview 1 integrated in the safety circuit further travel is not possible if activated 2 direction related power off the lift can travel in the opposite direction 3 optional in the safety circuit further travel is not possible if activated ...

Страница 5: ... service contract with your dealer Intended purpose of use The T80 platform lift is intended for the transport of wheelchair users and or people with reduced mobility The platform travels between fixed access points along a permanently installed rail which can be implemented straight or curved The platform is guided over the stairs or an accessible inclined surface by the running rail The system m...

Страница 6: ...form lift must have unrestricted mental abilities Operators with seriously impaired vision may be transported only with an attendant whereby the attendant issues the driving commands Furthermore the operator must have read and understand the operating instructions Product description Our products combine the requirements for overcoming stairs with outstanding integration in the familiar environmen...

Страница 7: ... switch situated inside 7 Hand grip 8 Emergency call 9 Left safety barrier 10 Folding seat option 11 Cover for motor controller 12 Right drive on ramp 13 Contact base 14 Safety plate 15 Lateral drive on ramp alternative to item 14 L1 Main switch ON lamp L2 Overload lamp 1 15 13 12 11 14 3 4 5 6 7 2 8 9 10 Platform lift with metal hood front cladding L1 L2 ...

Страница 8: ...l unit on spiral cable option 5 Platform hood 6 Main switch situated inside 7 Holding bar 8 Emergency call 9 Left safety barrier 10 Folding seat optional extra also with safety belt 11 Cover for motor controller 12 Right drive on ramp 13 Contact base 14 Safety plate 15 Lateral drive on ramp alternative to item 14 16 Emergency release 12 1 15 13 11 14 3 4 5 6 7 2 8 9 10 16 ...

Страница 9: ... and the platform when the lift is moving Residual danger trapping of loose clothing etc Fold up the lift when not in use Residual danger tripping over Never place your hands near the running rail when the lift is moving Residual danger crushing Be sure to observe the track in the direction of travel when travelling Residual danger crushing Do not remove cut through or deform parts of the lift or ...

Страница 10: ...ger falling from the platform In the case of interior and exterior installations brief or permanent flooding of the lift is forbidden Remove dirt from the lift with a little polish or a damp cloth not with a water jet The load bearing equipment and track must be sufficiently well lit by daylight or electric lighting The electric lighting must be independent of timer circuits Minimum 50 lux at the ...

Страница 11: ...ency stop button this has no influence on the charging process Overload protector The T80 platform lift is equipped with an overload protector acoustic and visual In the case of the metal hood the orange light on the hood p 7 item L2 lights disappears in the case of the plastic hood the background lighting of the direction arrows goes out p 8 item 1 In addition the internal beeper emits a continuo...

Страница 12: ...ansmitter for fetching sending the platform lift GREEN batteries are OK ORANGE the battery power is diminishing renew the batteries at your earliest convenience RED the battery power is very low replace the batteries immediately Fetching and sending the platform lift special version 1 via the external control unit only with 3 position key switch p 7 8 item 2 for a trip with the platform open via t...

Страница 13: ...lding procedure then the platform is to be folded up or opened manually see paragraph 4 5 2 and customer service informed Manual platform The folding procedure at a step can may only be carried out by an attendant In order to fold up the platform by hand proceed as follows as shown below a Place the safety barriers in the horizontal position b Fold up the base of the platform c Lower the safety ba...

Страница 14: ... safety barrier has opened In the case of the manual platform release the pivot lever or button and open the safety barrier by hand In the case of a storey circuit more than two stations drive as follows with the T80 platform lift If the platform lift has reached one of the middle stations it stops there and in the case of the automatic platform raises the safety barriers If the platform lift in n...

Страница 15: ...s be towards the lower station less energy expenditure when turning the hand wheel The respective direction of rotation is indicated directly on the hand wheel Note If the cause of the standstill is not clear it should be assumed that the safety arrester has been triggered and that its safety switch has led to the lift switching off The safety arrester may only be reset by technical personnel In t...

Страница 16: ...Operating instructions T80PL 2010 16 21 01 2010 Lever Hand wheel Brake venting lever Bowden cable on uphill side marked red ...

Страница 17: ...same time turning the hand wheel on the end of the motor shaft see sketch overleaf In doing so the direction of travel should always be towards the lower station less energy expenditure when turning the hand wheel The respective direction of rotation is indicated directly on the hand wheel Note If the cause of the standstill is not clear it should be assumed that the safety arrester has been trigg...

Страница 18: ...he front cladding using a screwdriver or similar Push the visible bolt forwards The uphill side safety barrier can then be raised manually at the same time The operator can now be helped out at the uphill side The platform must be folded up by hand so that the platform lift does not block the staircase see 4 5 2 In order to gain access to the main switch on the plastic version the screws must be r...

Страница 19: ...urther versions in addition to the standard version A gong which is activated wirelessly The transmitter which is powered by a separate battery is located on the platform hood and relays the emergency call signal to the gong wireless The range lies between 40 m in non built up areas and at least 10 m in built up areas The best method of making an emergency call is however still with a mobile telep...

Страница 20: ...e key switches correctly only 0 except at the operating see 4 5 or 4 6 Lift does not station chosen by you fold In the case of wireless operating Replace the transmitter batteries automatically stations are the transmitter batteries OK If you cannot repair the error yourself in this way please inform your customer service 7 Acoustic warning signals Duration sec Pause sec Reason Remedial action 0 1...

Страница 21: ...2010 21 21 01 2010 8 Services performed on your T80 platform lift at a glance Installed on Serial no Installed by TÜV acceptance on No Date Service performed Signature 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 ...