Operating instructions T80PL 2010 14/21 (01/2010)
4.6
Travelling with the platform lift
(standard version)
Ensure before each trip that the acoustic and, if present, the visual (optional) warning
signals work. The following control elements are located on the platform:
a) Key switch Function -I- and -0- (
p.7,8/item 2
)
b) Control unit Function UP and DOWN (
p.7, 8/item 1
)
c) Pushbutton EMERGENCY STOP (red button) (
p.7,8/item
3)
After driving or stepping onto the platform, insert the key and turn it to position -I-:
!
In the case of the
automatic
platform, the safety barrier closes electrically when
the pivot lever or button is pressed and held in the desired direction of travel. The
platform lift begins to move once the barrier has closed.
!
In the case of the
manual
platform,
first
close the safety barrier by hand
(horizontal position), then press and hold the pivot lever or button in the desired
direction of travel.
Upon reaching the destination station:
!
The platform lift stops automatically (the respective position is set during the
installation).
!
In the case of the automatic platform, press and hold the pivot lever or button until
the safety barrier has opened.
!
In the case of the manual platform, release the pivot lever or button and open the
safety barrier by hand.
In the case of a storey circuit (more than two stations), drive as follows with the
T80 platform lift:
!
If the platform lift has reached one of the middle stations, it stops there and, in the
case of the automatic platform, raises the safety barriers. If the platform lift in not
supposed to stop (open) there, then briefly release the control element and press it
again immediately so that the platform lift continues to drive.
Travelling with the platform lift
(special version 1) [via the external control unit,
with 3-position key switch (p.7, 8/item 2) for a trip with the platform open via the
external control unit]. This option must be activated by a specialist inside the
controller. It must be ensured that no third person can suddenly get/jump into the path
of the lift.
Condition: driving area is 100% in view !!!!
The key switch (p.7, 8/item 2) is to be placed in position -II-, otherwise the procedure
is the same as described under ‘standard version’, with the difference that only the
external control unit is used here.
Travelling with the platform lift
(special version 2)
The key switch (p.7, 8/item 2) is to be placed in position -I-, otherwise the procedure is
the same as described under ‘standard version’.