Page 17 

 

 

Precautions and safety instructions 

 

The Explo Trainer system is a simulation system. For reasons of safety, the system does not detect 
gas but ultrasonic signals. The system therefore cannot be used as a real gas meter. 

Do not use the 

system in an environment in which you suspect that there may actually be a potentially 
explosive mix of gases! 
 

 

The system is not waterproof. Never use it in the rain or in places where fire -extinguishing materials 
are used. Contact with water may permanently damage the system, in which case any resulting 
damage will not be covered by the product guarantee. 
 

 

Never use the system if the casing or cables are damaged and if you suspect a potential risk for the 
instructor or trainee. In this event, contact the manufacturer and have the system repaired.  
 

 

If necessary, clean the equipment with a damp cloth (using a mild all -purpose household cleaning 
agent if necessary). The casing is not resistant to chemicals such as alcohol, thinner or acetone. 
 

 

If no units are being charged, disconnect the battery charger from the mains power.   
 

 

Once the training session has been completed, it is best to store the set back in the supplied carry 
case. You can thus be sure that the system will be well protected. 

 

Guarantee 

From date of purchase, the Explo Trainer system carries a year's full guarantee on materials, call out 
charges and hourly rates.

 

Defects caused by wrongful use, damage caused by falling or external factors that  damage the Explo 
Trainer system are not covered by the guarantee. 
 

 

Содержание EXPLO TRAINER

Страница 1: ...Version 1 1 18 06 19 USER S MANUAL EXPLO TRAINER ORIGINAL USER S MANUAL...

Страница 2: ...sion 1 1 18 06 19 Page 1 Contents General description 2 Technical specifications 3 Use 4 Channel and language setup 14 Inspection and maintenance 16 Precautions and safety instructions 17 Guarantee 17...

Страница 3: ...of the transmitters thus simulating one of the four gases selectable An alarm sounds if the measured value exceeds the preset alarm value The instructor also receives an alarm signal if one of the ala...

Страница 4: ...n preset measured values are exceeded user configurable Low battery power Max distance from Instructor Unit approx 35 m in open space Radio frequency 869 5 MHz Transmitting power 10 mW Battery 7 2 V 7...

Страница 5: ...smitters in the area in which the gas cloud is to be simulated The control unit can be positioned out of sight and the much smaller transmission points can be positioned inconspicuously as long as the...

Страница 6: ...ow have a range of approx 5 meters 10 LEL in an open space The range is greatly dependent on reflections in the area It is therefore possible for the range to vary in the vicinity of obstacles Switchi...

Страница 7: ...le anymore the battery needs to be recharged Student Unit Operation The Student Unit is operated by means of a single button controlling all the functions of the gas meter It features optical and audi...

Страница 8: ...then only taken using the probe Take the probe and connect the probe s connector to the connector 2 of the Student Unit Maximum and minimum measured values Display maximum measured values Press the bu...

Страница 9: ...the battery Battery fully charged Battery half charged No need to recharge yet Battery power low Figure 3 7 Battery indicators Charging Connect unit s charger connector 7 to the battery charger and pl...

Страница 10: ...igure 3 8 The device will then automatically switch to measuring mode Four measurements are shown Lower Explosion Limit LEL Oxygen O2 Hydrogen Sulfide H2S Carbon Monoxide CO The transmitter symbol sho...

Страница 11: ...ch back to measuring mode after six seconds Delete minimum measured Oxygen value When the minimum measured Oxygen value is shown press and hold the button for two seconds The minimum measured Oxygen v...

Страница 12: ...4 shortly to go back to measuring mode Setting Alarm values A2 Press and hold the mode button 6 for at least 2 seconds The device will show the Alarm values A1 menu Press and hold the mode button 6 a...

Страница 13: ...sired measurement is selected Press the power button 4 shortly to go back to measuring mode Switching off When in measuring mode press and hold the button for four seconds until the LION logo appears...

Страница 14: ...hts continuously When a battery is completely empty before recharging the device will start a trickle charge cycle to prevent battery damage The green charging indicator will immediately light continu...

Страница 15: ...set up the settings correctly before accepting or declining them on the Student Unit A Student Unit will only ask for confirmation once If a user accidentally makes the wrong decision e g declining i...

Страница 16: ...by pressing and holding the power button on the Student Unit Be sure that the Student Unit is switched on and that you see the settings display Press and hold the power button until the Student Unit g...

Страница 17: ...is working properly At the same time check whether the measured value is being sent to the Instructor Unit Then do the same for the other transmitters Make sure that the system is adequately charged...

Страница 18: ...or cables are damaged and if you suspect a potential risk for the instructor or trainee In this event contact the manufacturer and have the system repaired If necessary clean the equipment with a dam...

Страница 19: ...ed values on the Student Unit Check whether both devices are set to the same channel Check whether both batteries are sufficiently charged and check whether both devices are within range For the purpo...

Страница 20: ...06 19 Page 19 Version 1 1 18 06 19 LION Protects B V Industrieweg 5 5111 ND Baarle Nassau the Netherlands T 31 0 13 507 6800 F 31 0 13 507 6808 E infoEMEA lionprotects com WWW LIONPROTECTS COM LION G...

Отзывы: