![LION EXPLO TRAINER Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/lion/explo-trainer/explo-trainer_user-manual_1926184011.webp)
Explo Trainer
User’s Manual
Version 1.1 | 18/06/19
Page 10
Maximum and minimum measured values
Display maximum measured values
-
Press the button briefly to show the
maximum measured values on the display.
The meter will show the maximum measured values
on the display (figure 3.10), and then automatically switch
back to measuring mode after six seconds.
Delete maximum measured values
-
When the maximum measured values are shown,
press and hold the button for two seconds.
The maximum measured values will be deleted. After six seconds, the Student Unit will automatically
switch back to measuring mode.
Display minimum measured Oxygen value
-
Press the button twice (briefly) to show the
minimum measured Oxygen value
on the display.
The meter will show the minimum measured Oxygen value
on the display (figure 3.11), and then automatically switch
back to measuring mode after six seconds.
Delete minimum measured Oxygen value
-
When the minimum measured Oxygen value is shown,
press and hold the button for two seconds.
The minimum measured Oxygen value will be deleted. After six seconds, the Student Unit will
automatically switch back to measuring mode.
Adjusting values manually
-
Press the mode button (6) shortly to point the arrow at the desir ed measurement
After each press, the arrow will move to the next measurement. The measurement connected to the
transmitters cannot be adjusted manually.
-
Use the up (7) and down (8) buttons to adjust the level of the selected measurement to the
desired level.
The level will increase/decrease in full steps of the last digit; e.g. 10
→
11 %LEL or 20.9
→
21 %O
2
.
Holding the up or down button will increase/decrease the number faster.
Range
The range of the four measurements:
•
%LEL:
0
– 100 in steps of 1
•
%O2:
0
– 25.5 in steps of 0.1
•
ppm H2S:
0
– 200 in steps of 1
•
ppm CO:
0
– 500 in steps of 1
Figure 3.10: Maximum values
display
Figure 3.11: Minimum values display