manualshive.com logo in svg
background image

Glossary

10BaseT - An Ethernet standard that uses twisted wire pairs.

100BaseTX - IEEE physical layer specification for 100 Mbps over two pairs of
Category 5 UTP wire.

1000BASE-T - provides half-duplex (CSMA/CD) and full-duplex 1000Mbps
Ethernet service over Category 5e links as defined by ANSI/TIA/EIA-568-A.
Topology rules for 1000BASE-T are the same as those used for 100BASE-TX.
Category 5e link lengths are limited to 100 meters by the ANSI/TIA/EIA-568-
A cabling standard. Only one CSMA/CD repeater will be allowed in a collision
domain.  

Adapter - Printed circuit board that plugs into a PC to add to capabilities or
connectivity to a PC. In a networked environment, a network interface card
(NIC) is the typical adapter that allows the PC or server to connect to the
intranet and/or Internet.

Auto-negotiate - To automatically determine the correct settings. The term is
often used with communications and networking. For example, Ethernet
10/100 cards, hubs and switches can determine the highest speed of the node
they are connected to and adjust their transmission rate accordingly.

Backbone - The part of a network that connects most of the systems and net-
works together and handles the most data.

Bandwidth - The transmission capacity of a given facility, in terms of how
much data the facility can 
transmit in a fixed amount of time; expressed in bits per second (bps).

CAT 3 - ANSI/EIA (American National Standards Institute/Electronic
Industries Association) Standard 568 is one of several standards that specify
"categories" (the singular is commonly referred to as "CAT") of twisted pair
cabling systems (wires, junctions, and connectors) in terms of the data rates
that they can sustain. CAT 3 cable has a maximum throughput of  16 Mbps and
is usually utilized for 10BaseT networks.

CAT 5 - ANSI/EIA (American National Standards Institute/Electronic
Industries Association) Standard 568 is one of several standards that specify
"categories" (the singular is commonly referred to as "CAT") of twisted pair
cabling systems (wires, junctions, and connectors) in terms of the data rates
that they can sustain. CAT 5 cable has a maximum throughput of  100 Mbps
and is usually utilized for 100BaseTX networks.

CAT 5e - The additional cabling performance parameters of return loss and far-
end crosstalk (FEXT) specified for 1000BASE-T and not specified for
10BASE-T and 100BASE-TX are related to differences in the signaling imple-
mentation. 10BASE-T and 100BASE-TX signaling is unidirectional-signals
are transmitted in one direction on a single wire pair. In contrast, Gigabit
Ethernet is bi-directional-signals are transmitted simultaneously in both direc-
tions on the same wire pair; that is, both the transmit and receive pair occupy
the same wire pair .  

Data Packet - One frame in a packet-switched message. Most data communi-
cations is based on dividing the transmitted message into packets. For example,
an Ethernet packet can be from 64 to 1518 bytes in length.

Dynamic Routing - The ability for a router to forward data via a different route
based on the current conditions of the communications circuits. For example, it
can adjust for overloaded traffic or failing lines and is much more flexible than
static routing, which uses a fixed forwarding path.

Ethernet - IEEE standard network protocol that specifies how data is placed on
and retrieved from a common transmission medium. Has a transfer rate of 10
Mbps. Forms the underlying transport vehicle used by several upper-level proto-
cols, including TCP/IP and XNS.

Fast Ethernet - A 100 Mbps technology based on the 10BASE-T Ethernet
CSMA/CD network access method.

Full Duplex - The ability of a device or line to transmit data simultaneously in
both directions.

Half Duplex - Data transmission that can occur in two directions over a single
line, but only one direction at a time.

Hardware - Hardware is the physical aspect of computers, telecommunications,
and other information technology devices. The term arose as a way to distinguish
the "box" and the electronic circuitry and components of a computer from the pro-
gram you put in it to make it do things. The program came to be known as the soft-
ware.

24

Instant Gigabit

®

Series

EtherFast

®

Dual Gigabit with 24-Port 10/100 Switch

25

Содержание EF24G2 - EtherFast Dual Gigabit

Страница 1: ...EtherFast Dual Gigabit with 24 Port 10 100 Switch Use this guide to install Linksys EtherFast Dual Gigabit with 24 Port 10 100 Switch EF24G2 User Guide Instant Gigabit Series...

Страница 2: ...sys makes no warranty or representation expressed implied or statutory with respect to its products or the contents or use of this documentation and all accompa nying software and specifically disclai...

Страница 3: ...Gigabit ports and connect your workstations to any of the available 10 100 ports and you ve maximized your network In addition the Switch has easy hassle free setup with no configuration required Sav...

Страница 4: ...ting in full duplex mode and flicker amber when collisions are being encountered GIGABIT PER PORT G1 G2 1000Link Green The LED will illuminate when the Gigabit Port is successfully connected to a netw...

Страница 5: ...gh 5 Instant Gigabit Series The EtherFast Dual Gigabit with 24 Port 10 100 Switch is equipped with twenty four 10 100 RJ 45 ports These RJ 45 ports support network speeds of either 10Mbps or 100Mbps a...

Страница 6: ...ed in any standard 19 inch rack Use the following instructions to rack mount the Switch Before you begin disconnect all cables from the Switch 1 Place the Switch right side up with the front panel fac...

Страница 7: ...ing click the arrow and choose the COM port that the Switch will be connected to In the example below COM1 is the port selected Click the OK button 8 EtherFast Dual Gigabit with 24 Port 10 100 Switch...

Страница 8: ...ows you configure speed duplex and flow control admin status and auto negotiation Port Trunking Configuration allows you trunk ports together for faster backplane speeds in data transmission Port Mirr...

Страница 9: ...twork in order to deliver data to that MAC address signifi cantly preserving network bandwidth After the specified amount of time passes the Switch will dump the inactive MAC address meaning that when...

Страница 10: ...screen that indicates whether or not the change was accepted The default setting for this value is Enabled Speed Duplex Current This value is automatically determined by the Switch and cannot be chang...

Страница 11: ...omatically determined for these two ports by the Switch and cannot be changed by the user Speed Duplex This value is automatically determined for these two ports by the Switch and cannot be changed by...

Страница 12: ...Port mirroring allows the user to assign two different ports to carry the same data stream This is a diag nostic tool that permits the user to verify that all data is being transmitted and received p...

Страница 13: ...ort causing your Switch to malfunc tion The VLAN Configuration Menu Link Status and Admin Status Same as the other 24 ports See the beginning of this section Auto Negotiate This value is automatically...

Страница 14: ...shold see above Each of the 26 ports are listed Using the arrow keys highlight the port you wish to set the priority value for and press the Space Bar key This will toggle between the options 0 7 Once...

Страница 15: ...s wires junctions and connectors in terms of the data rates that they can sustain CAT 5 cable has a maximum throughput of 100 Mbps and is usually utilized for 100BaseTX networks CAT 5e The additional...

Страница 16: ...number Mbps MegaBits Per Second One million bits per second unit of measure ment for data transmission Network A system that transmits any combination of voice video and or data between users NIC Netw...

Страница 17: ...0 C to 70 C 40 F to 158 F Operating Humidity 20 to 95 Non Condensing Storage Humidity 20 to 95 Non Condensing Environmental Warranty Information BE SURE TO HAVE YOUR PROOF OF PURCHASE AND A BARCODE FR...

Страница 18: ...nksys Customer Support at one of the phone numbers or Internet addresses below Sales Information 800 546 5797 LINKSYS Tech Support and RMA Issues 800 326 7114 949 261 1288 Fax 949 261 8868 Email suppo...

Страница 19: ...Copyright 2001 Linksys All Rights Reserved Printed in the USA http www linksys com...

Отзывы: