receive a message in the white status bar near the bottom of the screen that
indicates whether or not the change was accepted.  Highlight the value
next to Monitor Port Rx and hit the hit the Enter key.  Enter the number
of the port that you wish to mirror the received transmissions to (if you are
mirroring received transmissions), and hit the Enter key again.  You will
receive a message in the white status bar near the bottom of the screen that
indicates whether or not the change was accepted.  Only one port may be
mirrored (transmissions and received transmissions) at a time.  

Once you have made all the changes you wish to make, highlight Return
and hit the Enter key to return to the Main Menu.

A Virtual Local Area Network (VLAN) is a method of separating some of the
ports of a switch or hub into a smaller subgroup and making this group its
own network.  The VLAN Configuration Menu screen (shown here), allows
you to view or change the following values:

N

No

otte

e:: The two Gigabit ports may only mirror each

other, because of their speed.  Do not attempt to
mirror a Gigabit port to a regular port, or you will
overload that port, causing your Switch to malfunc-
tion.

The VLAN Configuration Menu

• Link Status and Admin Status - Same as the other 24 ports.  See the

beginning of this section.  

• Auto Negotiate -  This value is automatically determined for these two

ports by the Switch and cannot be changed by the user.  

• Speed/Duplex - This value is automatically determined for these two ports

by the Switch and cannot be changed by the user.  

• Flow Control - (Off - BothWay - SendOnly - Rcv/BothWay) Flow control

for the Gigabit ports is slightly more complex because of the greater speed
involved.  Flow control for these two ports can be disabled (Off), set to
monitor both transmitting and receiving (BothWay), set to monitor just the
transmitting (SendOnly), or just the receiving (Rcv/BothWay).  To change
the value, highlight the desired port under Flow Control and press the
Space Bar key.  This will toggle back and forth between the 4 different
options.  Once you have made your choice, press the Enter key.  You will
receive a message in the white status bar near the bottom of the screen that
indicates whether or not the change was accepted.  The default setting for
this value is Off.

Once you have made all the changes you wish to make, highlight Return
and hit the Enter key to return to the Main Menu.

20

Instant Gigabit

®

Series

21

EtherFast

®

Dual Gigabit with 24-Port 10/100 Switch

Содержание EF24G2 - EtherFast Dual Gigabit

Страница 1: ...EtherFast Dual Gigabit with 24 Port 10 100 Switch Use this guide to install Linksys EtherFast Dual Gigabit with 24 Port 10 100 Switch EF24G2 User Guide Instant Gigabit Series...

Страница 2: ...sys makes no warranty or representation expressed implied or statutory with respect to its products or the contents or use of this documentation and all accompa nying software and specifically disclai...

Страница 3: ...Gigabit ports and connect your workstations to any of the available 10 100 ports and you ve maximized your network In addition the Switch has easy hassle free setup with no configuration required Sav...

Страница 4: ...ting in full duplex mode and flicker amber when collisions are being encountered GIGABIT PER PORT G1 G2 1000Link Green The LED will illuminate when the Gigabit Port is successfully connected to a netw...

Страница 5: ...gh 5 Instant Gigabit Series The EtherFast Dual Gigabit with 24 Port 10 100 Switch is equipped with twenty four 10 100 RJ 45 ports These RJ 45 ports support network speeds of either 10Mbps or 100Mbps a...

Страница 6: ...ed in any standard 19 inch rack Use the following instructions to rack mount the Switch Before you begin disconnect all cables from the Switch 1 Place the Switch right side up with the front panel fac...

Страница 7: ...ing click the arrow and choose the COM port that the Switch will be connected to In the example below COM1 is the port selected Click the OK button 8 EtherFast Dual Gigabit with 24 Port 10 100 Switch...

Страница 8: ...ows you configure speed duplex and flow control admin status and auto negotiation Port Trunking Configuration allows you trunk ports together for faster backplane speeds in data transmission Port Mirr...

Страница 9: ...twork in order to deliver data to that MAC address signifi cantly preserving network bandwidth After the specified amount of time passes the Switch will dump the inactive MAC address meaning that when...

Страница 10: ...screen that indicates whether or not the change was accepted The default setting for this value is Enabled Speed Duplex Current This value is automatically determined by the Switch and cannot be chang...

Страница 11: ...omatically determined for these two ports by the Switch and cannot be changed by the user Speed Duplex This value is automatically determined for these two ports by the Switch and cannot be changed by...

Страница 12: ...Port mirroring allows the user to assign two different ports to carry the same data stream This is a diag nostic tool that permits the user to verify that all data is being transmitted and received p...

Страница 13: ...ort causing your Switch to malfunc tion The VLAN Configuration Menu Link Status and Admin Status Same as the other 24 ports See the beginning of this section Auto Negotiate This value is automatically...

Страница 14: ...shold see above Each of the 26 ports are listed Using the arrow keys highlight the port you wish to set the priority value for and press the Space Bar key This will toggle between the options 0 7 Once...

Страница 15: ...s wires junctions and connectors in terms of the data rates that they can sustain CAT 5 cable has a maximum throughput of 100 Mbps and is usually utilized for 100BaseTX networks CAT 5e The additional...

Страница 16: ...number Mbps MegaBits Per Second One million bits per second unit of measure ment for data transmission Network A system that transmits any combination of voice video and or data between users NIC Netw...

Страница 17: ...0 C to 70 C 40 F to 158 F Operating Humidity 20 to 95 Non Condensing Storage Humidity 20 to 95 Non Condensing Environmental Warranty Information BE SURE TO HAVE YOUR PROOF OF PURCHASE AND A BARCODE FR...

Страница 18: ...nksys Customer Support at one of the phone numbers or Internet addresses below Sales Information 800 546 5797 LINKSYS Tech Support and RMA Issues 800 326 7114 949 261 1288 Fax 949 261 8868 Email suppo...

Страница 19: ...Copyright 2001 Linksys All Rights Reserved Printed in the USA http www linksys com...

Отзывы: