4.1.1 Parameter programming 

The initial state for programming is signaled by the programming confirmation tone. The unit will always 
revert to this state after 5 seconds of inactivity, even if you have started to program a parameter. 
 
When programming, there are two types of parameters. The majority are parameters with a 

fixed 

length. 

The parameter is always saved immediately and is confirmed by Parameter Confirmation tone. 

Parameters 

with variable length 

(parameters 

1,2,32,33,34) 

are saved after the inactivity period 

expires (5 sec). However, a variable length parameter will be saved immediately when maximum 
permitted number of digits is reached. For parameters 1 and 2 the maximum number of digits is 16, and 
for parameters 32,33,34 it is 6. 
 
If, during programming, you enter a number that is not allowable, then the unit immediately emits an 

error tone. 

The parameter will not be recorded or changed, and the unit will return to its initial 

programming state and it will be possible to repeat the parameter setting or program another 
parameter. 
 
The unit stays inactive in programming mode for 34 seconds and will then automatically hang up. Every 
time a DTMF tone is dialed, this period is reset. Alternatively, parameter 9 may also be selected to end 
programming mode. 
To program a parameter, enter the parameter number followed by the value you wish to set. The unit 
will either respond with the Parameter Confirmation Tone, or one of the Error Tones.  
 

 

Note 1. 

if you wish to maintain the connection in programming mode (i.e. extend the 34 seconds 

period) then it is necessary to occasionally press a key (e.g. *, # or 7). The unit will respond with 
an error tone but the connection will be kept alive. 
 

 

Note 2. 

The # sign is not used in the values for parameters 32,33 and 34, and can be used to 

immediately save the parameter. 

 

 

 

 

Note 3. 

If you hang up the phone during programming mode without press 9, the doorphone will 

stay in programming mode during 30 seconds. 

 

 
 
 

4.2 PC programming – Smile DoorPhone Config programm 

To setup the unit from a PC you will require a special USB tool cable, available separately, and must first 
install the USB driver and software. Refer to the CD for more details. The unit must also be connected to 
the telephone line. 
 
 

Procedure

 

 

Connect the 

Smile Doorphone

 to the phone line  

 

Connect the unit to the PC with the special USB cable.  

 

Run the software program. The unit will enter PC programming mode and emit the 

Enter 

programming tone 

If connection is lost, it is necessary to disconnect the USB cable from unit 

and connect it again. The unit will answer and, providing the program is running, it will confirm its 
entry into programming mode again.  

 

When the connection is correct, you can the firmware version of Smile DoorPhone (visible in bar). 

 
 

Содержание link smile

Страница 1: ...kcom France 11 rue du Soleil Levant 92140 CLAMART Copyright 2009 Linkcom All rights reserved 1 Link Smile DoorPhone Manual v1 0 Please find the latest version of the manual and firmware at www linkcom...

Страница 2: ...ing call 8 3 3 2 Incoming call 8 4 Parameter programming 8 4 1 Programming from a telephone by DTMF 8 4 1 1 Parameter programming 9 4 2 PC programming Smile DoorPhone Config programm 9 5 Parameter des...

Страница 3: ...s forgotten the incoming call is going directly to programming mode and you can set new password 2 Heating switch ON integrated heating of motherboard to increase resistance against condensation water...

Страница 4: ...Linkcom France 11 rue du Soleil Levant 92140 CLAMART Copyright 2011 Linkcom All rights reserved 4 2 Installation 2 1 Assembly Open and close the cover Dismounting lighting of nameplate...

Страница 5: ...ART Copyright 2011 Linkcom All rights reserved 5 2 2 Wall mounting The installation is made by a screwing and dowels Return lighting nameplate after mounting on the wall Each button has its separate n...

Страница 6: ...e used also for electrical lock powering Then we recommend power supply 12V 1A You can also use 24V DC power supply It is useful mainly at installations where power supply is already installed and it...

Страница 7: ...2 Visitor at the door When the visitor finds the desired name and push it the Smile DoorPhone pick up the line and play the tone line pick up when is not switch off by parameter 62 and calls the phone...

Страница 8: ...r dialing the PBX extension number to which the unit is connected the unit will ring for the set number of rings parameter 51 the unit will lift up and it is possible to speak The possibilities are th...

Страница 9: ...ay also be selected to end programming mode To program a parameter enter the parameter number followed by the value you wish to set The unit will either respond with the Parameter Confirmation Tone or...

Страница 10: ...e stored Refer to the table for other choices Numbers saved in parameter 2 are numbers of second group or numbers of Night mode Default settings doesn t erase as same as changed those saved numbers No...

Страница 11: ...utton for call prolongation or 10 sec before Maximum Call Duration the unit will emit a tone Pressing this button will prolong the call Parameter Value Description Default 43 g bb End call 00 99 0 9 1...

Страница 12: ...it e 0 for 2 Group mode e 1 for Day Night mode Parameter Value Description Default 4 k End call by push again the same button 0 1 1 k line hanging up by push of same button k 0 feature is switch off k...

Страница 13: ...ss dialing up to 2 seconds after line on hook Parameter Value Description Default 56 hh Number of rings before hanging up or group mode switching 04 99 12 h specifies the amount of time spent ringing...

Страница 14: ...rrespond to 500 1400ms Time p is also time of pause between numbers at pulse dialing Parameter Value Description Default 507 uu Level of sending tone DTMF dial in dBm 04 16 10 uu level of sending tone...

Страница 15: ...ing to call 0 1 0 With this feature you can identify at PBX calling from the doorphone just up knocking into call u 0 knocking to call is off u 1 knocking to call is on Parameter Value description Def...

Страница 16: ...eres setting Parameter Value Description Default 71 gg Reception loudness 01 16 TRH 07 72 ff Transmission loudness 01 16 MIC 07 73 rr Speaker loudness 01 16 SPK 07 gg ff rr 2 digits in range 01 16 Aft...

Страница 17: ...Fast switching voice automatic 1 4 4 is slowest 2 At Parameters 75 76 is described principal of acoustic shock suppression Speed of circuit switching between incoming and outgoing sound is setup by Pa...

Страница 18: ...mbers stored in memory Parameter Value Description Default 81 Deletes all numbers in group 1 Day mode 82 Deletes all numbers in group 2 Night mode 83 Default settings only for parameters 3x 84 Default...

Страница 19: ...intercom by phone 00 99 0 9 155 266 44 xxxx Service password 0000 9999 0000 45 dd Command to switch into DAY 00 99 0 9 11 46 nn Command switch into NIGHT 0099 0 9 10 47 e Door intercom dial mode 0 1...

Страница 20: ...number 0 1 0 6 t Delay start for PBX s with extension test Siemens 0 1 0 71 gg Reception loudness 01 16 16 is highest TRH 07 72 ff Transmission loudness 01 16 16 is highest MIC 07 73 rr Speaker loudn...

Страница 21: ...l 115nF Line OFF HOOK Bandwidth 300Hz 3400 Hz 20 60mA Ringing impedance 2Kohm 25 60 Hz Sensitivity of ringing detector min 10 25 V Pulse dial 40 60 ms Tone dial level 6 and 8 dB 20 60 mA Sensitivity o...

Отзывы: