5.9. Parameters overview
Parameter Value
Description
Default
1
tt nn…
number
nn
under button
tt
-
2
tt nn…
number
nn
under button
tt
-
31
r m
relay
r
works in mode
m
(1-8)
11 21
35
r aa
command
aa
from phone for closing relay
r
1 pulse (00-99,*0-
*9)
155 266
36
r cc
command
aa
from phone for closing relay
r
2 pulses (00-
99,*0-*9)
150 260
37
r ss
time
ss
[sec] relay closing
r
for time
t1/t4
(01-99)
105 205
41
v
Dial type
v
– tone / pulse (0/1)
0
42
z
Character for call prolongation (* /
#)
*
43
g bb
Command to hang up door intercom by
phone
(00-
99,*0-*9)
155 266
44
xxxx
Service password (0000-
9999)
0000
45
dd
Command to switch into
DAY
(00-99,*0-
*9)
11
46
nn
Command switch into
NIGHT
(0099,*0-
*9)
10
47
e
Door intercom dial mode
(0/1)
1
4*
k
Feature of line hanging up by again push of
the same button
(0/1)
1
51
q
Number of rings before door intercom pick
up incoming call
(1-9)
2
52
d
Maximal call duration (0-
9,*,#)
2
53
w
Time between button push (1-
9)
2
54
z
Hang up time before REDIAL (1-
5)
2
55
z
Time before dial start
(1-5)
1
56
hh
Number of ringing before hang up (04-
99)
12
500
x
Middle frequency of tone detector (1-
0)
3 (375-
475Hz)
501
y
Number of busy tones
(2-0)
4
502
z
Duration time of permanent tone
(1-5)
3 (3s)
503
tt
Duration time of tone DTMF of tone dial
(04-16)
10 (100ms)
504
mm
Time of space between each DTMF tones
(04-16)