Linkcom France
11 rue du Soleil Levant 92140 CLAMART Copyright © 2011 – Linkcom – All rights reserved
12
45
dd
Day mode switching
(00-99,*0-*9)
11
46
nn
Night mode switching
(00-99,*0-*9)
10
dd
– command to switch into
DAY
mode [2 digits]
nn
– command to switch into
NIGHT
mode [2 digits]
Note.
The switchover to
Day/Night mode
remains set in unit even after line disconnection.
Parameter Value
Description
Default
47
e
Dialing mode (0/1)
1
e
– operating mode of unit
e=0 for 2 Group mode, e=1 for Day/Night mode.
Parameter Value
Description
Default
4*
k
End call by push again the same button
(0/1)
1
k
– line hanging up by push of same button:
k=0
feature is switch off
k=1
again button push hang up the line
5.4. Time parameters
Parameter Value
Description
Default
51
q
Number of rings before picks up (1-9)
2
q
– number of incoming call rings .
Parameter Value
Description
Default
52
d
Maximal call duration (0-9,*,#)
2
D
– Maximum time in minutes for which a call may last. This time can be extended
during a call by dialing Prolong Call digit from telephone (
∗
or #). Time setting is per
table.
time[min] Dial
0,5
0
1 - 9
1 -
9
15
*
30
#