The Linde Group Warranty  
Gas Detection Products

General

The Linde Group warrants gas detectors,  

sensors and accessories manufactured and sold  

by The Linde Group to be free from defects in 

materials and workmanship for the periods listed in 

the following tables. Damages to any Linde Group 

products that result from abuse, alteration, power 

fluctuations including surges and lightning strikes, 

incorrect voltage settings, incorrect batteries, or 

repair procedures not made in accordance with the 

product’s Operating Manual, are not covered by 

The Linde Group warranty.

The obligation of The Linde Group under this 

warranty is limited to the repair or replacement 

of components deemed by The Linde Group 

Service Department to have been defective under 

the scope of this standard warranty. To receive 

consideration for warranty repair or replacement 

procedures, products must be returned with 

transportation and shipping charges prepaid to 

The Linde Group, or to a Linde Group Authorised 

Warranty Service Centre. It is necessary to obtain a 

return authorisation number from The Linde Group 

prior to shipment.

THIS WARRANTY IS EXPRESSLY IN LIEU OF ANY AND 
ALL OTHER WARRANTIES AND REPRESENTATIONS, 
EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED 
TO, THE WARRANTY OF FITNESS FOR A PARTICULAR 
PURPOSE. The Linde Group WILL NOT BE LIABLE 
FOR LOSS OR DAMAGE OF ANY KIND CONNECTED 
TO THE USE OF ITS PRODUCTS OR FAILURE OF ITS 
PRODUCTS TO FUNCTION OR OPERATE PROPERLY.

Warranty periods for instruments  
and accessories

Product

Warranty period

G-TECTA

®

 SG 

G-TECTA

®

 4G

G-TECTA

®

 4GP

2 years from  
date of purchase

G-TECTA

®

 SG2

2 years from  
date of purchase

G-DOCKA

®

 SG2

1 year from  
date of purchase

G-DOCKA

®

 Hub

2 years from  
date of purchase

Instrument chargers/
interfaces

2 years from  
date of purchase

Warranty periods for sensors

Sensor type

Warranty period

Oxygen and 
Flammable Sensors

2 years

H

2

S & CO 

Toxic Sensors

2 years

All other  
Toxic Sensors

1 year

** Damage to combustible gas sensors by acute or 
chronic exposure to known sensor poisons such as 
volatile lead (aviation gasoline additive), hydride gases 
such as phosphine, and volatile silicone gases emitted 
from silicone caulks/sealants, silicone rubber moulded 
products, laboratory glassware greases, spray lubricants, 
heat-transfer fluids, waxes and polishing compounds 
(neat or spray aerosols), mould-release agents for 
plastics injection-moulding operations, waterproofing 
formulations, vinyl and leather preservatives, and 
hand lotions that may contain ingredients listed as 
cyclomethicone, dimethicone and polymethicone (at the 
discretion of The Linde Group Service department) void 
The Linde Group’s Standard Warranty as it applies to the 
replacement of combustible gas sensors.

Содержание G-TECTA SG

Страница 1: ...G TECTA SG Premium Single Gas Detection Instrument Operating Manual UK...

Страница 2: ...tion given in both our printed and online publications are accurate at the time of issue full technical specifications are not necessarily included Furthermore The Linde Group policy is one of continu...

Страница 3: ...call The Linde Group WARNING The accuracy of G TECTA SG instruments equipped with a toxic gas sensor should be checked periodically with known concentration calibration gas Failure to check accuracy...

Страница 4: ...in a non hazardous safe area Users can only change non rechargeable batteries in G TECTA SG instruments 9 The equipment is not certified for use in atmospheres containing more than 21 Oxygen Area Clas...

Страница 5: ...e button and a high quality display with automatic backlight The instrument continuously monitors the gas level in the environment providing current peak and time weighted average TWA readings for the...

Страница 6: ...ill display the warning message CAL When CAL is displayed the instrument can still function as a standard feature although we strongly recommend that the instrument is sent for calibration as soon as...

Страница 7: ...minutes or LTWA 8 hours WARNING TWA alarms cannot be cleared TWA alarms are functional for toxic gas instruments only Display Menu Options The G TECTA SG menu is displayed when you press the mode butt...

Страница 8: ...levels exceed 100 LEL G TECTA SG locks into alarm and displays 9999 showing an over range condition G TECTA SG will temporarily cut off power to the sensor to prevent burn out and display a progress...

Страница 9: ...The Event log can record over 4800 events Batteries Rechargeable Batteries The re chargeable batteries in the G TECTA SG are Li Ion batteries The batteries will re charge in less than 6 hours when ful...

Страница 10: ...attery pack 1 Ensure you are in a safe non hazardous area 2 Always switch the G TECTA SG off before opening the case to change the battery 3 Remove the back cover and remove the battery pack 4 Replace...

Страница 11: ...sample to reach the sensor Continue to squeeze the bulb for an additional 45 seconds or until gas readings stabilise 6 To remove the flow cap gently unclip the cap from the sensor and lift it away fr...

Страница 12: ...ng down G TECTA SG will display PASS or FAIL Note In the event G TECTA SG displays FAIL please see the bump test calibration troubleshooting guide or contact The Linde Group 6 To abort the gas test pr...

Страница 13: ...as flow rate It is important that the flow rate is set correctly as otherwise pressure effects may distort calibration values and prevent the gas detector from working correctly To calibrate the flow...

Страница 14: ...instrument Gas flow not started in time Repeat gas test Start gas immediately Instrument fails calibration Gas cylinder empty Check cylinder gauge Replace cylinder Gas cylinder out of date Check cylin...

Страница 15: ...CTA PC software options screen and note the ports available ii Switch on the G TECTA SG instrument and drop it into the charger cradle iii Check the available communications ports available again and...

Страница 16: ...ds Visible alarms Dual colour Blue Red flashing LEDs Vibrating alarm Internal vibrating Repeatability 2 FSD 6 months Electromagnetic Compatibility 2004 108 EC Explosion Protection Certification IECEx...

Страница 17: ...ralian ASSG1061 G TECTA SG 230v Battery Charger UK ASSG1062 G TECTA SG 230v Battery Charger Europe ASSG1063 G TECTA SG 110v Battery Charger USA ASSG1064 G TECTA SG 230v Battery Charger Australian c w...

Страница 18: ...ailure Do NOT use instrument Exit hazardous area immediately and return instrument for service Auto Zero failure Instrument zeroed in contaminated atmosphere Switch off instrument and restart in clean...

Страница 19: ...es or oxygen contain chemicals Extreme levels of humidity can cause problems The sensors are rated for an average ambient humidity of 15 90 R H However the sensors are commonly used from the tropics t...

Страница 20: ...seefa 1180 Buxton UK Provisions of the Directive fulfilled by the products Group II Category 2G Ex ia d IIC T4 Gb 20 C Ta 65 C IP65 Flammable Group II Category 1G Ex ia IIC T4 Ga 20 C Ta 65 C IP65 Oxy...

Страница 21: ...Y OF FITNESS FOR A PARTICULAR PURPOSE The Linde Group WILL NOT BE LIABLE FOR LOSS OR DAMAGE OF ANY KIND CONNECTED TO THE USE OF ITS PRODUCTS OR FAILURE OF ITS PRODUCTS TO FUNCTION OR OPERATE PROPERLY...

Страница 22: ...22 UK Notes...

Страница 23: ...23 UK Notes...

Страница 24: ...f going to print Denmark AGA A S Vermlandsgade 55 2300 K benhavn S Tel 45 32 83 66 00 Estonia Eesti AGA AS P rnu mnt 141 11314 Tallinn Tel 372 6504 500 Finland Oy AGA Ab Itsehallintokuja 6 02600 Espoo...

Отзывы: