Linde G-TECTA SG Скачать руководство пользователя страница 3

3

UK

2. 

 The G-TECTA

®

 SG may be used in Zones 1 

and 2 for flammable versions and Zones 0, 

1, and 2 for toxic and oxygen versions. Both 

versions can be used for Group IIA, IIB, and IIC 

gases and vapours for Temperature Classes T1, 

T2, T3 and T4.

Flammable Gas

Baseefa09ATEX0240

Ex ia d 

II

C T4 Gb -4F/-20ºC 

≤ ta ≤ 

149F/65ºC

N694

The Linde Group, GU2 7XY, UK

1180

 

II 

2G

www.g-tecta.com

G-TECTA    

  

SG

  

BAR CODE 

IIIIIIIIII

IECEx

  BAS 09.0115

Oxygen or Toxic Gas

BAR CODE 

IIIIIIIIII

www.g-tecta.com

G-TECTA    

  

SG

  

Baseefa09ATEX0244

Ex ia 

II

C T4 Ga -4F/-20ºC 

≤ ta ≤ 

149F/65ºC

The Linde Group, GU2 7XY, UK

N694

1180

 

II 

1G

IECEx

  BAS 09.0116

Safety and Warning information

WARNING

 Read and understand all 

instructions in the operation section of this 

operating manual before use.

WARNING

 Do not substitute components 

as this may impair intrinsic safety and invalidate 

warranty.

WARNING

 Observe all warnings and 

instructions marked on the instrument and within 

this operating manual.

WARNING

 Observe site health and safety 

procedures for gases being monitored and 

evacuation procedures.

WARNING

 Make sure you understand the 

alarm warnings.

WARNING

 If this product is not working 

properly, read the operating manual or call 

The Linde Group.

WARNING

 The accuracy of G-TECTA

®

 SG 

instruments equipped with a toxic gas sensor 

should be checked periodically with known 

concentration calibration gas. Failure to check 

accuracy can lead to inaccurate and potentially 

dangerous readings. G-TECTA

®

 SG instruments 

equipped with an oxygen sensor should be 

periodically calibrated in fresh air.

WARNING

 Ensure maintenance and 

calibrations are carried out in accordance with the 

procedures in the operating manual.

WARNING

 The equipment is not certified 

for use in atmospheres containing more than 21% 

oxygen.

WARNING

 G-TECTA

®

 SG portable gas 

detectors have been designed for the detection 

of either oxygen deficiencies or specific toxic gas 

accumulations. An alarm condition indicates the 

presence of a potentially life threatening hazard 

and should be taken very seriously.

WARNING

 Ensure only qualified service 

personnel change sensors, batteries and operating 

system.

WARNING

 Only charge batteries in safe 

(non-hazardous) areas.

Instructions – specific for use in 
hazardous areas

The following instructions apply to 

equipment covered by certificate numbers 

Baseefa09ATEX0240 Flammable Gas 

Baseefa09ATEX0244 Oxygen or Toxic Gas

The following information covers all relevant points 

listed in clause 1.0.6 of the Essential Health & Safety 

Requirements of the ATEX directive.

1. 

 The certification marking is as follows:

Содержание G-TECTA SG

Страница 1: ...G TECTA SG Premium Single Gas Detection Instrument Operating Manual UK...

Страница 2: ...tion given in both our printed and online publications are accurate at the time of issue full technical specifications are not necessarily included Furthermore The Linde Group policy is one of continu...

Страница 3: ...call The Linde Group WARNING The accuracy of G TECTA SG instruments equipped with a toxic gas sensor should be checked periodically with known concentration calibration gas Failure to check accuracy...

Страница 4: ...in a non hazardous safe area Users can only change non rechargeable batteries in G TECTA SG instruments 9 The equipment is not certified for use in atmospheres containing more than 21 Oxygen Area Clas...

Страница 5: ...e button and a high quality display with automatic backlight The instrument continuously monitors the gas level in the environment providing current peak and time weighted average TWA readings for the...

Страница 6: ...ill display the warning message CAL When CAL is displayed the instrument can still function as a standard feature although we strongly recommend that the instrument is sent for calibration as soon as...

Страница 7: ...minutes or LTWA 8 hours WARNING TWA alarms cannot be cleared TWA alarms are functional for toxic gas instruments only Display Menu Options The G TECTA SG menu is displayed when you press the mode butt...

Страница 8: ...levels exceed 100 LEL G TECTA SG locks into alarm and displays 9999 showing an over range condition G TECTA SG will temporarily cut off power to the sensor to prevent burn out and display a progress...

Страница 9: ...The Event log can record over 4800 events Batteries Rechargeable Batteries The re chargeable batteries in the G TECTA SG are Li Ion batteries The batteries will re charge in less than 6 hours when ful...

Страница 10: ...attery pack 1 Ensure you are in a safe non hazardous area 2 Always switch the G TECTA SG off before opening the case to change the battery 3 Remove the back cover and remove the battery pack 4 Replace...

Страница 11: ...sample to reach the sensor Continue to squeeze the bulb for an additional 45 seconds or until gas readings stabilise 6 To remove the flow cap gently unclip the cap from the sensor and lift it away fr...

Страница 12: ...ng down G TECTA SG will display PASS or FAIL Note In the event G TECTA SG displays FAIL please see the bump test calibration troubleshooting guide or contact The Linde Group 6 To abort the gas test pr...

Страница 13: ...as flow rate It is important that the flow rate is set correctly as otherwise pressure effects may distort calibration values and prevent the gas detector from working correctly To calibrate the flow...

Страница 14: ...instrument Gas flow not started in time Repeat gas test Start gas immediately Instrument fails calibration Gas cylinder empty Check cylinder gauge Replace cylinder Gas cylinder out of date Check cylin...

Страница 15: ...CTA PC software options screen and note the ports available ii Switch on the G TECTA SG instrument and drop it into the charger cradle iii Check the available communications ports available again and...

Страница 16: ...ds Visible alarms Dual colour Blue Red flashing LEDs Vibrating alarm Internal vibrating Repeatability 2 FSD 6 months Electromagnetic Compatibility 2004 108 EC Explosion Protection Certification IECEx...

Страница 17: ...ralian ASSG1061 G TECTA SG 230v Battery Charger UK ASSG1062 G TECTA SG 230v Battery Charger Europe ASSG1063 G TECTA SG 110v Battery Charger USA ASSG1064 G TECTA SG 230v Battery Charger Australian c w...

Страница 18: ...ailure Do NOT use instrument Exit hazardous area immediately and return instrument for service Auto Zero failure Instrument zeroed in contaminated atmosphere Switch off instrument and restart in clean...

Страница 19: ...es or oxygen contain chemicals Extreme levels of humidity can cause problems The sensors are rated for an average ambient humidity of 15 90 R H However the sensors are commonly used from the tropics t...

Страница 20: ...seefa 1180 Buxton UK Provisions of the Directive fulfilled by the products Group II Category 2G Ex ia d IIC T4 Gb 20 C Ta 65 C IP65 Flammable Group II Category 1G Ex ia IIC T4 Ga 20 C Ta 65 C IP65 Oxy...

Страница 21: ...Y OF FITNESS FOR A PARTICULAR PURPOSE The Linde Group WILL NOT BE LIABLE FOR LOSS OR DAMAGE OF ANY KIND CONNECTED TO THE USE OF ITS PRODUCTS OR FAILURE OF ITS PRODUCTS TO FUNCTION OR OPERATE PROPERLY...

Страница 22: ...22 UK Notes...

Страница 23: ...23 UK Notes...

Страница 24: ...f going to print Denmark AGA A S Vermlandsgade 55 2300 K benhavn S Tel 45 32 83 66 00 Estonia Eesti AGA AS P rnu mnt 141 11314 Tallinn Tel 372 6504 500 Finland Oy AGA Ab Itsehallintokuja 6 02600 Espoo...

Отзывы: