Linddana A/S
. Ølholm Bygade 70 . DK-7160 Tørring . T +45 75 80 52 00 . [email protected] . www.linddana.com
Brugsanvisning: TP 230 fra dato 02.11.2015 ©Copyright 2008
22
8.3.6
Adjusting V-belts
The feed rollers are hydraulically powered. The hydraulic pump for the feed rollers is powered by
V-belts. The V-belts must be checked at regular intervals or if you suspect they are slack.
What to do:
Stop the machine and turn off any power. Remove the bolts holding the two sections of the rotor
housing together and open the rotor housing.
Loosen the four bolts holding the hydraulic pump in place and adjust the tension using the
adjusting screw. Used belts may yield 5.5 mm when pushed down using 38 N (3.8 kg), the figure
for new belts is 43 N (4.3 kg) (see Figure 21). The belts can be measured using a special measuring
instrument, which can be purchased as extra equipment.
Figure 21 Tightening V-belts
Once the V-belts have been tightened, turn the rotor several revolutions to ensure there are no
objects in the rotor housing. Now close the rotor housing and replace the bolts (See Figure 13).