6. Assembly
6.1 General information
Only qualified technical personnel may install the products
specified in the instructions.
The product should, to the extent possible, be protected from
humidity and vibration, and should be mounted so that it is
easily accessible, allowing all further installation work to be
done without difficulty.
During assembly and especially when drilling assembly holes
on the system, always pay attention to the following:
•
Check the flow limiter for any shipping damages and for
completeness.
•
The IP safety class must be observed.
•
The flow limiter must be connected with the equipotential
bonding of the higher-level machine via the equipotential
bonding connection of the base plate of the base module (see
Fig. 30, Chapter 6.5 ).
•
See the connection diagrams below for the measurements
and port dimensions.
•
No radial or axial active forces may occur at the flow limiter.
•
The flow limiter must be installed in a stress-free position.
•
Other units must not be damaged by assembly work.
•
The product must not be installed within range of moving
parts.
•
The product must be installed at a sufficiently large distance
from sources of heat or cold.
•
Maintain safety clearances and comply with statutory
regulations for assembly and accident prevention.
•
Drill the assembly holes as specified in this chapter.
•
Carefully clean screw unions and tubing prior to beginning
installation.
•
It must be ensured that screw unions, connections, and
connection elements are leak-free.
•
Ensure cleanliness; components must be installed without
contamination.
•
Do not use any cleaning wipes containing lint.
•
Follow the mounting position requirements in "Technical
data" (Chapter 4. ).
<
WARNING
Explosion hazard from non-ATEX-compliant
attachments and monitoring equipment.
Only attachment and monitoring equipment
suitable for the respective explosion protection
class is permitted for use.
<
WARNING
Explosion hazard
The lubricant’s ignition temperature has to be at
least 50 kelvin above the maximum permissible
surface temperature.
<
CAUTION
Slipping hazard
Centralized lubrication systems must always be
free of leaks. Leaking lubricant is hazardous. It
creates a risk of slipping and injury.
Beware of any lubricant leaking out during
assembly, operation, maintenance, or repair of
centralized lubrication systems.
Leaks must be sealed off without delay.
<
WARNING
Bursting hazard
The lubrication system must be secured with a
pressure relief valve,
the maximum opening pressure of which is
determined by the maximum permissible pressure
of the flow limiter design – see Chapter 4. /
"Technical data".
6.2 Minimum mounting dimensions
To ensure enough space for maintenance work and for any
disassembly of the product, ensure that the minimum mounting
dimensions (Figs. 15to Figs. 29) are maintained.
<
IMPORTANT NOTE
Possible damage to the components
Provide sufficient space for assembly and for any
protective devices which may be required if the
parts are subject to damage.