Impinger I -–1000 Series Service Manual - International 

Fan, and the Heat and Conveyor Switches. 

TRANSFORMER (12.6 

VAC) 

Upon closure of the Fan Switch, 120 VAC is supplied to the primary of the 12.6 VAC 

Transformer. The Transformer steps the voltage down to 12.6 VAC (normally 13 to 

14 VAC) with a center tap, and supplies power to the Time/Temp Display. The 

voltage from each leg of the Transformer's secondary to the center tap should be 

one half of the secondary voltage. 

HEAT CIRCUIT 

Closing the Fan Switch and the normally open Heat Switch supplies 120 VAC 

through the normally open Air Pressure Switch, and the normally closed Hi-Limit 

Thermostat (manually re-settable, opens at 368°C) through the 3A Fuse, to the 

Temperature Control Board, the coil of the Mercury Contactor, and to the Heat 

Indicator Light. 

TEMPERATURE 

CONTROL 

When the Heat Switch is closed, 120 VAC is supplied to the Temperature Control. 

The Temperature Control Potentiometer (2.5K ohm) is adjusted to desired 

temperature. The Thermocouple will provide varying millivolts to the Temperature 

Controller. The Temperature Controller switches the L2 line of the Contactor coil at 

intermittent intervals to maintain desired temperature. 

CONVEYOR DRIVE 

(S/N 4390 AND UP) 

Closing the fan switch and the normally open conveyor switch supplies 120 VAC to 

the Motor Control Board AC volts are converted to DC volts and are supplied to the 

Conveyor Motor at terminals A+ and A-. Adjustment of the Speed Control 

Potentiometer (5,000 ohm 10 turn ) will change resistance at terminals P1, P2, and 

P3 varying the DC voltage to the Conveyor Motor. The speed of the conveyor motor 

will increase or decrease as the DC voltage from the board increases or decreases 

respectively. As the motor turns, it drives both the reducer gear box and the tach. 

generator. The tach. generator is a DC voltage generator which supplies a voltage to 

the DC motor control board and is used as a reference for maintaining a constant 

conveyor speed. 

TIME TEMP DISPLAY 

The Time/Temp. Display is energized when the Fan Switch is closed, supplying 120 

VAC to the primary of the12.6 volt Transformer. The secondary output of the 

transformer, normally 13 to 14 VAC (depending on input), with a center tap, is 

supplied to terminals 1,2, and 3 of the Time/Temp. Display. The center tap is 

terminal 2.The display works on a balanced input and center tap voltage to each leg 

must be 1/2 the total reading. 

The speed side of the Time/Temp. Display uses a slotted disc (cemented to tach. 

coupling) to break the infra-red light beam of the optical switch (mounted on gear 

motor) producing electrical pulses that are transmitted to the display. The display 

converts these pulses into a read-out of minutes and seconds. 

The temperature portion of the display uses a Thermistor Probe to sense oven 

temperature. The thermistor outputs a resistance proportional to the oven 

temperature. This resistance is then converted by the display into a temperature 

reading. 

SEQUENCE OF OPERATIONS / 1033, 1034, 1046, 1047 

 

MODEL 1033 / 220 VAC - 50HZ / NATURAL GAS 

MODEL 1034 / 220 VAC - 50HZ / L.P. GAS 

MODEL 1046 / 240 VAC - 50HZ / NATURAL GAS 

MODEL 1047 / 240 VAC - 50HZ / L.P. GAS 

POWER SUPPLY 

Electrical Power to be supplies to the oven by a three-conductor service. 

Brown conductor is Hot 

Blue conductor is Neutral 

Green conductor is Ground 

CONTROL BOX AUTO 

COOL DOWN 

When the temperature in the Control Box reaches 120°F± 3°, the Cooling Fan 

Thermostat will switch power to the Control Box Cooling Fan. The Thermostat will 

interrupt power to the Cooling Fan when the Control Box temperature falls to 

100°F±3°. 

MAIN FAN CIRCUIT 

Electrical power is permanently supplied to the normally open contacts of the oven 

fan motor relay, the Cooling Fan Thermostat, and the normally open Oven Fan 

Switch.  Closing the oven fan switch supplies 220 VAC, through a 3 AMP Fuse, to the 

primary of the Power Transformer (the transformer steps the voltage down to 120 

VAC for the control circuit). 120 VAC is supplied to the Cooling Fan, the normally 

open Conveyor Switch, the Electronic Temperature Control, and to the coil of the 

Содержание Impinger 1002

Страница 1: ...CONVEYOR OVENS MODEL SERIES 1000 1200 Lincoln Foodservice Products LLC 1111 North Hadley Road Fort Wayne Indiana 46804 United States of America Phone 800 374 3004 U S Fax 888 790 8193 Int l Fax 260 43...

Страница 2: ...SHOOTING GUIDE 1000 1200 SERIES ELECTRIC OVENS 39 TROUBLESHOOTING GAS OVENS 1033 1034 1046 1047 46 REMOVAL INSTALLATION ADJUSTMENTS 53 MODEL SERIES 1000 1200 53 PARTS MODEL SERIES 1000 1200 GENERAL 80...

Страница 3: ...ransformer secondary supplies 24 VAC to the Relay Coil the normally open contacts close within 30 seconds and the normally open Centrifugal Switch When the Relay contacts close the Burner Blower Motor...

Страница 4: ...Step Down Transformer The transformer steps the voltage down to 120VAC for the control circuit 120 VAC is supplied to the coil of the Main Fan Relay The coil of the Relay is energized the normally op...

Страница 5: ...tor is Ground MAIN FAN CIRCUIT Electrical power is permanently supplied through 3 50A fuses to the normally open contacts of the Mercury Contactor Power is also supplied through 1 10A fuse to the norm...

Страница 6: ...leg must be 1 2 the total reading The speed side of the Time Temp Display uses a slotted disc cemented to tach coupling to break the infra red light beam of the optical switch mounted on gear motor pr...

Страница 7: ...veyor speed Time Temp Display Q17171 Above See Page 9 The Time Temp Display is energized when the Fan Switch is closed supplying 120 VAC to the primary of the 12 6 volt Transformer The secondary outpu...

Страница 8: ...aintaining a constant conveyor speed TIME TEMP DISPLAY The Time Temp Display is energized when the Fan Switch is closed supplying 120 VAC to the primary of the12 6 volt Transformer The secondary outpu...

Страница 9: ...me monitor proves main flame operation in the 1033 1034 models CONVEYOR DRIVE Closing the Oven Fan Switch supplies 120 VAC through the Power Transformer to the normally open Conveyor Switch Closing th...

Страница 10: ...itch supplies 120 VAC through the Air Pressure Switch to the Temperature Control Board the normally open contacts of the Burner Motor Relay Burner Motor Relay discontinued after S N 14791 and the prim...

Страница 11: ...Display The center tap is terminal 2 The display works on a balanced input and center tap voltage to each leg must be 1 2 the total reading The speed side of the Time Temp Display uses a slotted disc...

Страница 12: ...Impinger I 1000 Series Service Manual International 12 SCHEMATIC 1002 1003...

Страница 13: ...Impinger I 1000 Series Service Manual International 13 SCHEMATIC 1006 TO SERIAL NUMBERS Q14279...

Страница 14: ...Impinger I 1000 Series Service Manual International 14 SCHEMATIC 1028 1029 S N Q19071 BELOW...

Страница 15: ...Impinger I 1000 Series Service Manual International 15 SCHEMATIC 1028 1029 S N Q19078 ABOVE...

Страница 16: ...Impinger I 1000 Series Service Manual International 16 SCHEMATIC 1030 TO S N Q17170...

Страница 17: ...Impinger I 1000 Series Service Manual International 17 SCHEMATIC 1030 S N Q17171 ABOVE...

Страница 18: ...Impinger I 1000 Series Service Manual International 18 SCHEMATIC 1032 S N Q19077 BELOW...

Страница 19: ...Impinger I 1000 Series Service Manual International 19 SCHEMATIC 1032 S N Q19078 ABOVE...

Страница 20: ...Impinger I 1000 Series Service Manual International 20 SCHEMATIC 1033 1034 1046 1047...

Страница 21: ...Impinger I 1000 Series Service Manual International 21 SCHEMATIC 1042 1043 S N Q14279 BELOW...

Страница 22: ...Impinger I 1000 Series Service Manual International 22 SCHEMATIC 1042 1043 S N Q14280 ABOVE...

Страница 23: ...Impinger I 1000 Series Service Manual International 23 SCHEMATIC 1228 1229 S N Q14790 BELOW...

Страница 24: ...Impinger I 1000 Series Service Manual International 24 SCHEMATIC 1228 1229 S N Q14791 ABOVE...

Страница 25: ...Impinger I 1000 Series Service Manual International 25 SCHEMATIC 1242 1243...

Страница 26: ...equipped with Control Box Cooling Fan NOTE Main Fan Relay Export Ovens Axial Cooling Fan Check for power to Main Fan Relay Visually check for contact pull in For ovens equipped with a control circuit...

Страница 27: ...valve If voltage is not present replace electronic control package If the pilot valve is energized check to see that the high voltage ignitor circuit is also energized To check disconnect the ignitor...

Страница 28: ...ignition control replace the Burner Blower Motor These Ignition Controls have a 30 second pre purge Delay and a 15 second lock out time The Ignition Control will try for ignition for 15 seconds and t...

Страница 29: ...00 ohm 1 turn WITH POWER OFF check ohms across red and black leads the ohm reading should be 0 to1000 ohms as the dial is turned From green to red the reading should be 1000 ohms steady throughout the...

Страница 30: ...f lights of main power main fan off air pressure switch out 1 on 2 off 3 on 4 off 5 off 6 off Burner Motor Relay bad 1 on 2 on 3 on 4 off 5 off 6 off Burner Motor Centrifugal Switch bad 1 on 2 on 3 on...

Страница 31: ...s not exceeding temperature dial setting check for proper location of capillary bulb in its spring holder If above checks okay replace hi limit thermostat Ignition Control Check for 220 VAC supply to...

Страница 32: ...age to flame sensor wire and connections Ignition Control If there is sufficient flame sensor current but the burner will not remain ignited check reset button on ignition control if all above are oka...

Страница 33: ...k leads This ohm reading should be a steady 400 ohm or 500 ohm through the entire 10 turn rotation of the potentiometer Red to white should be 0 400 or 0 500 ohms as the pot is rotated Check for short...

Страница 34: ...C voltage is not present check the 4 amp and the 1 amp fuses on the control board If 120 VAC is present at terminals L1 and L2 but DC voltage is not present at A and A providing the 1 amp and 4 amp fu...

Страница 35: ...ould always be attempted at least once before replacement See procedure for board adjustment on page 65 DC Gear motor If the DC control board is steadythen the problem may be the motor or gearbox Chec...

Страница 36: ...3 7 4 8 WITH POWER OFF Turn the motor shaft to check for jammed gear box If motor shaft will not turn replace conveyor drive stepper motor Time Temp Display inoperative 12 6 VAC Power Supply Measure t...

Страница 37: ...in the red wires leading from the 12 6 VAC transformer to the display If this does not solve the problem it may be coming in through the commercial power lines Suggest that customer contact his power...

Страница 38: ...ose from motorshaft Replace as needed Hall Effect Sensor Check for any physical damage to Hall Effect sensor mounted on conveyor drive stepper motor Check all wiring and connections for damage Time Di...

Страница 39: ...is open replace Main Fan Relay Check for power to main fan relay Visually check for contact pull in No control box cooling Axial Cooling Fan WITH POWER OFF turn the fan blade to check for locked roto...

Страница 40: ...necessary Heater Elements Check the Amp draw on each hot leg for proper load Check the specifications plate for rating information If the Amp draw is low or high check the individual elements for ope...

Страница 41: ...age reading of 120 VAC If no present check breakers 3 Amp Fuse This conveyor fuse is located on the front panel Replace if defective Fuseholder Check and or Replace Fan Switch See procedure for checki...

Страница 42: ...excessive bearing wear and sometimes irregular speed Power Supply Check power supply at the DC control board for the 120 VAC at board terminals L1 and L2 If voltage is not present check main circuit...

Страница 43: ...5 as the potentiometer is rotated through its 10 turn rotation Place the meter leads on the red lead and white lead Rotating the potentiometer slowly from low to high the meter should show an even tr...

Страница 44: ...sor bulb Also check each thermistor lead for short to ground Thermocouple Probe Place your pyrometer thermocouple into the center between fingers T2 and T3 in the oven Connect temperature meter to the...

Страница 45: ...replace the optical encoder assembly Conveyor Drive Stepper Control Perform all checks as in the above evaluation If the time check is okay refer to the next section Check to see if the conveyor driv...

Страница 46: ...2 and 6 of the relay if no voltage is present trace wiring back to the power supply If voltage is present at the relay coil check to insure the contacts are closing Fan Fuse Check replace if necessar...

Страница 47: ...one side of switch only check the following Check for proper gas pressure supply to gas valve Marked on oven spec plate Check for proper adjustment of gas pressure switch Should be set at 8 8 for Nat...

Страница 48: ...ck for gas pressure at pilot tube Disconnect pilot tube at burner and connect manometer to pilot tube If no gas pressure is present check for blockage in pilot tube If these are clear and there is gas...

Страница 49: ...20 VAC at the load terminal to neutral If 220 VAC is not present proceed as follows If 220 VAC is present and unit is not heating see Flame Monitor Check for 220 VAC at terminal COM on temperature con...

Страница 50: ...er if voltage is not present trace wiring back to the fuseholder If voltage is present check for output voltage from the transformer secondary NOTE this control transformer outputs 2 secondary voltage...

Страница 51: ...etween finger T2 and T3 in the oven Disconnect the yellow tipped thermistor leads from the time temp terminals 9 and 10 Measure the resistance of the thermistor probe Thermistor Probe See chart on pag...

Страница 52: ...okay refer to the next section Conveyor Drive Stepper Motor Check to see if the conveyor drive stepper motor is running If motor is not running refer to Conveyor will not run on page 50 Magnet Check t...

Страница 53: ...ove fan from motor shaft NOTE Measure distance from fan blade to rear wall assembly before removal to aid in reassembly 9 Remove the eight 8 hex head bolts from the motor mount and slide the motor ass...

Страница 54: ...ll wires and mark for replacement 5 Remove relay by removing two 2 mounting screws 6 Reassemble in reverse order COOL DOWN SWITCH 1 Shut off power at main breaker 2 Remove control panel top and front...

Страница 55: ...366 When It is used in the 3 ft Impinger Gas oven the following modification must be made 3 Remove control box and components mounted on burner blower motor 4 Mount transformer on air switch bracket a...

Страница 56: ...assemble in reverse order NOTE There is no critical placement of the blower wheel on the motor shaft Just back as far as it will go and then spin the blower to be sure it is not rubbing AIR PRESSURE S...

Страница 57: ...he gas piping from the back of the unit Remove the four 4 screws from the incoming nipple mounting bracket Remove incoming nipple Remove pilot tube assembly from control valve Disconnect pipe union ju...

Страница 58: ...2 of the bulb to the left of the spring holder NOTE The bypass screw should be adjusted all the way in SOLENOID VALVE 1 Shut off power at main breaker 2 Shut off gas supply 3 Remove control panel top...

Страница 59: ...17 7 94 9 49 10 26 11 03 12 57 14 11 15 65 C 84 F 3 43 4 94 6 47 7 23 8 00 9 54 10 31 11 09 12 63 14 19 15 71 T 82 F 3 49 5 00 6 53 7 29 8 06 9 60 10 37 11 14 12 69 14 23 15 76 I 80 F 3 55 5 06 6 59...

Страница 60: ...ion Control When mounting new ignition control make certain that the green 67 ground wire supplied is installed properly 7 Connect wiring as follows Connect blue wire from gas valve to terminal marked...

Страница 61: ...O PILOT LIGHT BLACK FROM VALVE BLUE FROM VALVE RING TERMINAL END OF WIRE HARNESS SUPPLIED IN KIT BUTT SPLICE AND NEW GREEN WIRE SUPPLIED IN KIT WHITE FROM PILOT LIGHT 24V FROM TRANSFORMER INSULATED MA...

Страница 62: ...each 7 See Burner blower motor section for wiring information 8 Replace covers and check system operation BURNER LIGHT 24 VAC GAS OVENS 1 Shut off power at main breaker 2 Remove control panel top and...

Страница 63: ...eed position 5 Slide dial assembly onto pot shaft and tighten set screw DIAL CONVEYOR SPEED CONTROL OVEN WITH DIGITAL DISPLAY 1 Shut off power at main breaker 2 Remove old dial by loosening set screw...

Страница 64: ...ft COUPLING AND ENCODER DISC 1 Shut off power at main breaker 2 Remove conveyor motor assembly 3 Remove dust cover above motor 4 Loosen both allen set screws 050 inch allen wrench located on coupling...

Страница 65: ...board NOTE Exchange boards on the mounting bracket before reinstallation 5 Reassemble in reverse order and calibrate See D C Motor Control Board Calibration SN 14975 AND ABOVE 1000 SERIES GAS OVENS S...

Страница 66: ...nect a digital volt meter to terminals A and A set meter on 200 VDC scale Turn speed control pot on oven control panel to its maximum speed setting Turn MAX MIN and IR pots counter clockwise until the...

Страница 67: ...cates 1 4 to 1 5 VDC Reset the speed control pot to its maximum speed setting and check if voltage is still at 22 6 to 22 8 VDC Readjust if necessary Reset the speed control pot to its maximum speed s...

Страница 68: ...RD P N 369272 P 1 1 A FUSE L 2 A T 1 T 2 L 1 A P 3 P 2 MAX MIN BOARD P N 369155 STYLE 2 4 A FUSE L 1 A L 2 A T 1 T 2 P 3 P 2 P 1 MAX MIN P1 CHOKE 1 A FUSE 4 A FUSE RESISTOR 4 A FUSE L 1 L 2 A A T 2 T...

Страница 69: ...FOR 50HZ SWITCH 3 OFF FOR F ON FOR C 3 With conveyor running set conveyor speed control so Time Temp Display indicates 5 00 minutes Place a pan on the conveyor measure STOPWATCH the time SPEED OF PAN...

Страница 70: ...792 AND ABOVE 1200 SERIES 1 Shut off power at main breaker 2 Remove control panel top 3 Remove relay box cover 4 Change position of dip switch 1 on stepper control board 5 Reassemble in reverse order...

Страница 71: ...assembly from conveyor 6 Remove bearing from mounting plate 7 Reassemble in reverse order TRANSFORMER STEPPER MOTOR CONTROL 1 Shut off power at main breaker 2 Remove control panel top and front cover...

Страница 72: ...48 38 24 16 Place test pyrometer thermocouple and preheat oven as specified under temperature calibration Disconnect the thermistor probe from terminals 9 and 10 and measure the resistance across the...

Страница 73: ...the display numbers match the measured time Seal adjustment pot with Glyptol or nail polish e Calibrate temperature Place a temperature sensor in between top two fingers and set temperature control t...

Страница 74: ...Y SET 1 Shut off power at main breaker 2 Remove control panel top 3 Disconnect wires from time temp display terminals 5 and 6 4 Pull off black operating knob and remove hex mounting nut 5 Reassemble i...

Страница 75: ...cess cover 4 Depress the spring clips on the sides of the switch and push out 5 Remove wires from back of switch Note wire number and location 6 Install new switch in reverse order and check SWITCH RE...

Страница 76: ...unit 3 Remove the four 4 screws from the incoming nipple mounting bracket 4 Remove incoming nipple 5 Disconnect two 2 plugs 1 3 prong and 1 4 prong Note location 6 Disconnect pipe union just above gas...

Страница 77: ...g sure capillary tube is placed securely in the wire form NOTE Depress reset button to insure thermostat is set for operation SPARK GENERATOR REPLACEMENT 1 Remove control panel top and front cover 2 L...

Страница 78: ...OTE After installation check all pipe fittings for leaks BURNER BLOWER MOTOR REPLACEMENT 1 Remove control panel top and front cover 2 Remove screws around blower tube 3 Disconnect motor wiring and rem...

Страница 79: ...and check system operation TEMPERATURE CONTROL REPLACEMENT 1046 1047 1 Remove control panel top and front cover 2 Remove one screw from control knob guard and move guard to one side 3 Remove temp cont...

Страница 80: ...nd Outlet 369211 Thumb Screw R 369369 Seam Cover Conveyor Opening S 369203 Stud Wing Head T 369749 Chain Cover Assy S N Q14974 Above U 369204 Split Ring Retainer V 369373 Receptacle Snap In W 369205 C...

Страница 81: ...Impinger I 1000 Series Service Manual International 81 BLOW UP 1000 1200 GENERAL...

Страница 82: ...r 230 460 575 VAC N L A See Burner Blower Motor Page 55 O 369531 Transformer 120 24V 40VA P 369366 Burner Blower Motor Kit Q 369009 Thermocouple R 369029 Temperature Gauge S 369108 Thermostat Knob Deg...

Страница 83: ...Impinger I 1000 Series Service Manual International 83 BLOW UP 1002 1003 S N 2584 TO 4389...

Страница 84: ...er Top LH S 369543 Transformer 230 460 575 T N L A See Burner Blower Motor Page 55 U 369531 Transformer 120 24V 40VA V 369366 Burner Blower Motor Kit W 369331 Finger Guard Cooling Fan X 369193 Thermis...

Страница 85: ...Impinger I 1000 Series Service Manual International 85 BLOW UP 1002 1003 S N 4390 ABOVE...

Страница 86: ...H S 369543 Transformer 230 460 575 VAC T N L A See Burner Blower Motor Page 55 U 369531 Transformer 120 24V 40VA V 369366 Burner Blower Motor Kit W 369331 Finger Guard Cooling Fan X 369193 Thermistor...

Страница 87: ...Impinger I 1000 Series Service Manual International 87 BLOW UP 1006...

Страница 88: ...22 L 369302 Contactor 50A 120V M 354258 Transformer 230V 115V N 369127 Hi Limit Thermostat 369368 Hi Limit Thermostat Bulb Capillary O 369154 0 7 Amp Circuit Breaker P 369118 Power Terminal Block Q 36...

Страница 89: ...Impinger I 1000 Series Service Manual International 89 BLOW UP 1028 1029 1032...

Страница 90: ...9 Alarm Burner Shutdown U 369331 Finger Guard Cooling Fan V 369368 Thermostat Hi Limit W 369573 Ignition Control 220 VAC X 369728 Temperature Control Thermostat Y 369085 Junction Box Z 369736 Terminal...

Страница 91: ...Impinger I 1000 Series Service Manual International 91 BLOW UP 1030...

Страница 92: ...369902 Sensing Rod Kit S 369154 7 Amp Circuit Breaker T 369393 Ignition Control NAT LP U 369331 Finger Guard Cooling Fan V 369085 Junction Box W 353082 Terminal Lug X 369398 4 Cover junction Box Blan...

Страница 93: ...Impinger I 1000 Series Service Manual International 93 BLOW UP 1042 1043...

Страница 94: ...69579 Alarm V 369574 Spark Generator W 369573 Ignition Control 369771 Push Button Switch X 369580 Gas Valve Multi Block Y 369571 Connector 4 Pole Z 369570 Connector 3 Pole AA 369398 Solenoid Valve Nat...

Страница 95: ...Impinger I 1000 Series Service Manual International 95 BLOW UP 1033 1034 1046 1047...

Страница 96: ...t Thermostat N 369118 60A Fuseholder O 369007 Temperature Sensing Switch 369902 Sensing Rod Kit Q 369119 60A Fuseholder R 369134 Fuse 50A S 369193 Thermistor Probe T 369167 Set Switch Assy 370046 Butt...

Страница 97: ...Impinger I 1000 Series Service Manual International 97 BLOW UP 1228 1229...

Страница 98: ...3 Thermister T 369167 Set Switch U 369172 Time Temp Display V 369316 Temperature Dial W 369263 Gas Valve Nat LP Body Only X 369344 Pilot Shut Off Valve Y 369086 Pilot Line Z 369398 Solenoid Valve Nat...

Страница 99: ...Impinger I 1000 Series Service Manual International 99 BLOW UP 1242 1243...

Страница 100: ...G 369213 Fan S N begins with a Q H See Page 108 I N L A See Conversion Kits Below J 369026 Heat Slinger Bar K 369215 Motor Support Assy S N Q4613 Above 369028 Motor Mount Support Assy S N 4612 Below...

Страница 101: ...Impinger I 1000 Series Service Manual International 101 BLOW UP OVEN BACK GAS...

Страница 102: ...369646 Rod Stand Off K 369026 Heat Slinger Bar L 369215 Motor Support Assy S N Q4768 Above 369028 Motor Mount Support Assy S N Q4767 Below M 369020 Oven Fan Motor S N Q4767 Below N 369027 Motor Coolin...

Страница 103: ...Impinger I 1000 Series Service Manual International 103 BLOW UP OVEN BACK ELECTRIC...

Страница 104: ...Coupling and Encoder Disc 050 in Allen Wrench included F 369146 Hex Nut 4 40 G 369294 4 Lockwasher H 369292 Bracket Tach Generator I 369297 Screw 6 32 x 1 4 J 369156 6 Lockwasher K 369293 Screw 4 40...

Страница 105: ...Impinger I 1000 Series Service Manual International 105 BLOW UP CONVEYOR MOTOR ASSEMBLY S N 4390 ABOVE...

Страница 106: ...6 Drive Sprocket S N Q14974 Above Gas S N Q19078 above Electric 369413 Drive Key K 369219 Rod End Female L 369644 Screw 1 2 20 x 3 4 M 369206 Crumb Pan N 369163 Conveyor Belt 369362 Conveyor Belt by F...

Страница 107: ...Impinger I 1000 Series Service Manual International 107 BLOW UP SERIES 1000 CONVEYOR...

Страница 108: ...9640 Conveyor Control Stepper S N Q14974 Above 357028 Fuse Non Delay 1A 250V 369201 Fuse 4 Amp 250V F 369272 Conveyor Motor Control B S N Q4613 to Q14973 357028 Fuse Non Delay 1A 250V 369201 Fuse 4 Am...

Страница 109: ...Impinger I 1000 Series Service Manual International 109 BLOW UP SERIES 1200 CONVEYOR CONTROL...

Страница 110: ...2 Sprocket 1 2 Bore H 369005 Conveyor Belt Connecting Links I 369280 Idler Shaft Inner J 369284 Collar Shaft Spacer K 369039 Blank Drive Gear L 369038 Roll Conveyor Notched M 369281 Idler Shaft Outer...

Страница 111: ...Impinger I 1000 Series Service Manual International 111 BLOW UP SERIES 1200 CONVEYOR...

Страница 112: ...Impinger I 1000 Series Service Manual International 112...