Speed Control Potentiometer This is a 0 to 400 ohm or 0 to 500 ohm, 10-turn
potentiometer. WITH POWER OFF: remove the
red, white, and black leads from terminals S1, S2,
S3. With a digital multimeter, check the ohm
reading across the red to black leads. This ohm
reading should be a steady 400-ohm, or 500-ohm,
through the entire 10-turn rotation of the
potentiometer. Check for shorts or opens or
unsteady, ohms reading, if potentiometer is
defective, replace. If the potentiometer checks OK,
and there is no output at terminals A1 and A2,
replace the D. C. control board.
Reversing Switch
If there is D. C. voltage output from the motor
control board, but the conveyor drive motor is not
running, check the D.P.D.T. reversing switch.
Conveyor Drive Motor
Check the conveyor drive sprocket for tightness.
Disconnect the motor, check the red and black
motor leads for opens, shorts or grounds. Check
the brushes for excessive or abnormal wear.
Replace as needed. Reconnect motor. Test for
operation. If motor does not run, replace.
Voltage Supply
Check incoming voltage supply at line 1 to neutral.
There should be a voltage reading of 120 VAC. If
no present, check breakers. 3 Amp Fuse. This
conveyor fuse is located on the front panel.
Replace if defective.
Fuseholder
Check and/or Replace.
Fan Switch
See procedure for checking on Page 26.
Conveyor will not
run(S/N 4390 to
Q190771000 Series)
(S/N 4390-
Q147901200 Series)
Conveyor Switch
Same procedure as for fan switch.
NOTE:
(Dual Belt Ovens)
Dual belt ovens utilize 2 complete independent
conveyor drive systems. The trouble shooting
procedures are the same as single belt ovens,
except that the dual belt ovens use one each of the
following: one "A" D. C. control board and one "B"
D. C. control board.
Speed Adjustment
Potentiometer
This is a 0 to 5 K ohm, 10 turn potentiometer With
power off, remove the red, black and white pot
leads from the motor control board at terminals P1,
P2 and P3. With a digital multimeter, check the
ohm reading across the red lead (P3) to the black
lead (P1). This reading should be 5 K ohms ± 5%
as the pot is rotated from low to high. Place the
meter leads on the red lead (P3) and on the white
lead (P2) Rotating the pot. slowly, from low to high,
the meter reading should show an even transition
from O to 5 K ohms ± 5%. There should be
no dead or open spots through out the 10 turns of
the pot. Check all three leads to ground. There
should be no continuity to ground. If any of the
above checks fail, replace the pot.
Содержание Impinger 1002
Страница 12: ...Impinger I 1000 Series Service Manual International 12 SCHEMATIC 1002 1003...
Страница 13: ...Impinger I 1000 Series Service Manual International 13 SCHEMATIC 1006 TO SERIAL NUMBERS Q14279...
Страница 14: ...Impinger I 1000 Series Service Manual International 14 SCHEMATIC 1028 1029 S N Q19071 BELOW...
Страница 15: ...Impinger I 1000 Series Service Manual International 15 SCHEMATIC 1028 1029 S N Q19078 ABOVE...
Страница 16: ...Impinger I 1000 Series Service Manual International 16 SCHEMATIC 1030 TO S N Q17170...
Страница 17: ...Impinger I 1000 Series Service Manual International 17 SCHEMATIC 1030 S N Q17171 ABOVE...
Страница 18: ...Impinger I 1000 Series Service Manual International 18 SCHEMATIC 1032 S N Q19077 BELOW...
Страница 19: ...Impinger I 1000 Series Service Manual International 19 SCHEMATIC 1032 S N Q19078 ABOVE...
Страница 20: ...Impinger I 1000 Series Service Manual International 20 SCHEMATIC 1033 1034 1046 1047...
Страница 21: ...Impinger I 1000 Series Service Manual International 21 SCHEMATIC 1042 1043 S N Q14279 BELOW...
Страница 22: ...Impinger I 1000 Series Service Manual International 22 SCHEMATIC 1042 1043 S N Q14280 ABOVE...
Страница 23: ...Impinger I 1000 Series Service Manual International 23 SCHEMATIC 1228 1229 S N Q14790 BELOW...
Страница 24: ...Impinger I 1000 Series Service Manual International 24 SCHEMATIC 1228 1229 S N Q14791 ABOVE...
Страница 25: ...Impinger I 1000 Series Service Manual International 25 SCHEMATIC 1242 1243...
Страница 81: ...Impinger I 1000 Series Service Manual International 81 BLOW UP 1000 1200 GENERAL...
Страница 83: ...Impinger I 1000 Series Service Manual International 83 BLOW UP 1002 1003 S N 2584 TO 4389...
Страница 85: ...Impinger I 1000 Series Service Manual International 85 BLOW UP 1002 1003 S N 4390 ABOVE...
Страница 87: ...Impinger I 1000 Series Service Manual International 87 BLOW UP 1006...
Страница 89: ...Impinger I 1000 Series Service Manual International 89 BLOW UP 1028 1029 1032...
Страница 91: ...Impinger I 1000 Series Service Manual International 91 BLOW UP 1030...
Страница 93: ...Impinger I 1000 Series Service Manual International 93 BLOW UP 1042 1043...
Страница 95: ...Impinger I 1000 Series Service Manual International 95 BLOW UP 1033 1034 1046 1047...
Страница 97: ...Impinger I 1000 Series Service Manual International 97 BLOW UP 1228 1229...
Страница 99: ...Impinger I 1000 Series Service Manual International 99 BLOW UP 1242 1243...
Страница 101: ...Impinger I 1000 Series Service Manual International 101 BLOW UP OVEN BACK GAS...
Страница 103: ...Impinger I 1000 Series Service Manual International 103 BLOW UP OVEN BACK ELECTRIC...
Страница 105: ...Impinger I 1000 Series Service Manual International 105 BLOW UP CONVEYOR MOTOR ASSEMBLY S N 4390 ABOVE...
Страница 107: ...Impinger I 1000 Series Service Manual International 107 BLOW UP SERIES 1000 CONVEYOR...
Страница 109: ...Impinger I 1000 Series Service Manual International 109 BLOW UP SERIES 1200 CONVEYOR CONTROL...
Страница 111: ...Impinger I 1000 Series Service Manual International 111 BLOW UP SERIES 1200 CONVEYOR...