Main Flame will not
stay lit
Flame Monitor
(There should be a visible main flame at this time.)
To check for flame monitor operation, connect a
digital volt meter (capable of measuring D.C. micro
amperes) between the flame sensor and terminal
#15 on the flame monitor. The flame monitor
requires a minimum of 4 micro amp. D.C. for proof
of flame. If these readings are not achieved,
replace sensor assembly. Also check for any type
of damage to flame sensor wire and connections.
If the reading is above the minimum required, and
the flame monitor will not supply 220 VAC to the
relay coil, replace the flame monitor.
Intermittent Heating
As Follows
Both the main fan motor and burner blower motor
are equipped with thermal protection and will cease
to operate if overheating occurs. This can cause
the units to cycle on and of intermittently. This may
be caused by improper ventilation. Also, most of
the problems listed under "oven will not heat" can
cause intermittent failure.
Conveyor Switch
Check for 120 VAC to conveyor switch. If no
voltage is present, trace wiring back to the power
supply. WITH POWER OFF: Check continuity
between switch terminals
Conveyor Fuse(3A)
Check, replace if necessary.
Fuseholder
Check, replace if necessary.
Conveyor Control
Check for 120 VAC supply to primary (Stepper)
Transformer of transformer, if voltage is not
present, trace wiring back to the fuseholder. If
voltage is present, check for output voltage from
the transformer secondary. NOTE: this control
transformer outputs (2) secondary voltages: Red
Leads 29 VAC Brown Leads 10 VAC. If BOTH
secondary voltages are not present, replace the
transformer.
Conveyor will not run
Speed Adjustment
Potentiometer
This is a 0 to 50K ohm, 10 turn potentiometer.
WITH POWER OFF: remove the 3 pin
potentiometer cable plug from the motor control
board. With a digital multimeter, check the ohm
reading across the red lead to the black lead, this
reading should be 50K ohms ± 5% as the
potentiometer is rotated through its 10 turn rotation.
Place the meter leads on the red lead and white
lead. Rotating the potentiometer slowly, from low to
high, the meter should show an even transition
from 0 to 50K ohms ± 5% through the 10 turn
rotation of the potentiometer. There should be no
dead or open spots through the 10 turns of the
potentiometer. Check all three leads to ground.
There should be no continuity to ground. If any of
the above checks fail, replace the potentiometer.
Conveyor Motor(Stepper)
Control
NOTE: if the conveyor drive motor becomes
jammed or begins to run at an uncontrolled speed,
the conveyor motor will stop running. To reset, turn
off the conveyor switch, wait 30 seconds, turn the
conveyor switch on. If the motor does not run after
attempting re-set, check for 2 to 29 VAC across the
motor terminals 1 to 2 and 3 to 5 on, the conveyor
motor control. If voltage is not present at both sets
of terminals, replace control.
Содержание Impinger 1002
Страница 12: ...Impinger I 1000 Series Service Manual International 12 SCHEMATIC 1002 1003...
Страница 13: ...Impinger I 1000 Series Service Manual International 13 SCHEMATIC 1006 TO SERIAL NUMBERS Q14279...
Страница 14: ...Impinger I 1000 Series Service Manual International 14 SCHEMATIC 1028 1029 S N Q19071 BELOW...
Страница 15: ...Impinger I 1000 Series Service Manual International 15 SCHEMATIC 1028 1029 S N Q19078 ABOVE...
Страница 16: ...Impinger I 1000 Series Service Manual International 16 SCHEMATIC 1030 TO S N Q17170...
Страница 17: ...Impinger I 1000 Series Service Manual International 17 SCHEMATIC 1030 S N Q17171 ABOVE...
Страница 18: ...Impinger I 1000 Series Service Manual International 18 SCHEMATIC 1032 S N Q19077 BELOW...
Страница 19: ...Impinger I 1000 Series Service Manual International 19 SCHEMATIC 1032 S N Q19078 ABOVE...
Страница 20: ...Impinger I 1000 Series Service Manual International 20 SCHEMATIC 1033 1034 1046 1047...
Страница 21: ...Impinger I 1000 Series Service Manual International 21 SCHEMATIC 1042 1043 S N Q14279 BELOW...
Страница 22: ...Impinger I 1000 Series Service Manual International 22 SCHEMATIC 1042 1043 S N Q14280 ABOVE...
Страница 23: ...Impinger I 1000 Series Service Manual International 23 SCHEMATIC 1228 1229 S N Q14790 BELOW...
Страница 24: ...Impinger I 1000 Series Service Manual International 24 SCHEMATIC 1228 1229 S N Q14791 ABOVE...
Страница 25: ...Impinger I 1000 Series Service Manual International 25 SCHEMATIC 1242 1243...
Страница 81: ...Impinger I 1000 Series Service Manual International 81 BLOW UP 1000 1200 GENERAL...
Страница 83: ...Impinger I 1000 Series Service Manual International 83 BLOW UP 1002 1003 S N 2584 TO 4389...
Страница 85: ...Impinger I 1000 Series Service Manual International 85 BLOW UP 1002 1003 S N 4390 ABOVE...
Страница 87: ...Impinger I 1000 Series Service Manual International 87 BLOW UP 1006...
Страница 89: ...Impinger I 1000 Series Service Manual International 89 BLOW UP 1028 1029 1032...
Страница 91: ...Impinger I 1000 Series Service Manual International 91 BLOW UP 1030...
Страница 93: ...Impinger I 1000 Series Service Manual International 93 BLOW UP 1042 1043...
Страница 95: ...Impinger I 1000 Series Service Manual International 95 BLOW UP 1033 1034 1046 1047...
Страница 97: ...Impinger I 1000 Series Service Manual International 97 BLOW UP 1228 1229...
Страница 99: ...Impinger I 1000 Series Service Manual International 99 BLOW UP 1242 1243...
Страница 101: ...Impinger I 1000 Series Service Manual International 101 BLOW UP OVEN BACK GAS...
Страница 103: ...Impinger I 1000 Series Service Manual International 103 BLOW UP OVEN BACK ELECTRIC...
Страница 105: ...Impinger I 1000 Series Service Manual International 105 BLOW UP CONVEYOR MOTOR ASSEMBLY S N 4390 ABOVE...
Страница 107: ...Impinger I 1000 Series Service Manual International 107 BLOW UP SERIES 1000 CONVEYOR...
Страница 109: ...Impinger I 1000 Series Service Manual International 109 BLOW UP SERIES 1200 CONVEYOR CONTROL...
Страница 111: ...Impinger I 1000 Series Service Manual International 111 BLOW UP SERIES 1200 CONVEYOR...
Страница 112: ...Impinger I 1000 Series Service Manual International 112...