![Lincoln Impinger 1002 Скачать руководство пользователя страница 62](http://html1.mh-extra.com/html/lincoln/impinger-1002/impinger-1002_service-manual_1917750062.webp)
Impinger I -–1000 Series Service Manual - International
62
BURNER IGNITOR
1.
Shut off power at main breaker.
2.
Remove control panel top and front cover.
3.
Remove burner assembly.
4.
Remove flame sensor.
5.
Remove pilot shield and pilot shield extension.
6.
Remove burner igniter.
7.
Reassemble in reverse order.
NOTE: Be sure to reconnect burner igniter cable to ignition control.
TRANSFORMER 120/24 VAC
1.
Remove control panel top and front cover.
2.
Remove control box cover from burner blower motor.
NOTE
: The complete burner blower motor assembly, with control box (PN 369359), is no longer
available. The blower motor assembly (PN 369265) has been changed to a
burner motor kit (PN 369366). If the burner blower motor or 24V transformer
(PN 369531 ) are replaced, the following modifications must be made:
3.
Shut off power at main breaker.
4.
Remove control box and components from burner blower motor.
5.
Mount transformer on air switch bracket (use transformer as template).
6.
Discard control box and relay.
Material needed: #29 drill bit and #8 x 3/8" self tapping screws (3 each)
7.
See Burner blower motor section for wiring information.
8.
Replace covers and check system operation.
BURNER LIGHT (24 VAC) - GAS OVENS
1.
Shut off power at main breaker.
2.
Remove control panel top and front panel.
3.
Remove access cover.
4.
Remove two wires from burner light, note number and location.
5.
Grasp body of light assembly and slide sideways to remove.
6.
Reassemble in reverse order and check.
HEAT LIGHT (125 VAC) - ELECTRIC OVENS
1.
Shut off power at main breaker.
2.
Remove control panel top and front panel.
3.
Remove two (2) wires from heat light, note number and location.
4.
Grasp body of light assembly and slide sideways to remove.
5.
Reassemble in reverse order and check.
THERMOSTAT, Hl-LIMIT - ELECTRIC OVENS
1.
Shut off power at main breaker.
2.
Remove control panel top and front cover.
3.
Remove the two (2) wires from the thermostat located on the back wall of the control box.
4.
Remove two (2) mounting screws.
5.
Reassemble in reverse order.
NOTE:
Be sure to press red "reset" button on new thermostat to ensure that it is in the
"closed" position.
PILOT ORIFICE - BURNER
1.
Shut off power at main breaker.
2.
Shut off gas supply.
3.
Remove burner assembly (see Burner Assembly).
4.
Remove pilot line from pilot orifice.
5.
Remove pilot orifice from burner igniter.
Содержание Impinger 1002
Страница 12: ...Impinger I 1000 Series Service Manual International 12 SCHEMATIC 1002 1003...
Страница 13: ...Impinger I 1000 Series Service Manual International 13 SCHEMATIC 1006 TO SERIAL NUMBERS Q14279...
Страница 14: ...Impinger I 1000 Series Service Manual International 14 SCHEMATIC 1028 1029 S N Q19071 BELOW...
Страница 15: ...Impinger I 1000 Series Service Manual International 15 SCHEMATIC 1028 1029 S N Q19078 ABOVE...
Страница 16: ...Impinger I 1000 Series Service Manual International 16 SCHEMATIC 1030 TO S N Q17170...
Страница 17: ...Impinger I 1000 Series Service Manual International 17 SCHEMATIC 1030 S N Q17171 ABOVE...
Страница 18: ...Impinger I 1000 Series Service Manual International 18 SCHEMATIC 1032 S N Q19077 BELOW...
Страница 19: ...Impinger I 1000 Series Service Manual International 19 SCHEMATIC 1032 S N Q19078 ABOVE...
Страница 20: ...Impinger I 1000 Series Service Manual International 20 SCHEMATIC 1033 1034 1046 1047...
Страница 21: ...Impinger I 1000 Series Service Manual International 21 SCHEMATIC 1042 1043 S N Q14279 BELOW...
Страница 22: ...Impinger I 1000 Series Service Manual International 22 SCHEMATIC 1042 1043 S N Q14280 ABOVE...
Страница 23: ...Impinger I 1000 Series Service Manual International 23 SCHEMATIC 1228 1229 S N Q14790 BELOW...
Страница 24: ...Impinger I 1000 Series Service Manual International 24 SCHEMATIC 1228 1229 S N Q14791 ABOVE...
Страница 25: ...Impinger I 1000 Series Service Manual International 25 SCHEMATIC 1242 1243...
Страница 81: ...Impinger I 1000 Series Service Manual International 81 BLOW UP 1000 1200 GENERAL...
Страница 83: ...Impinger I 1000 Series Service Manual International 83 BLOW UP 1002 1003 S N 2584 TO 4389...
Страница 85: ...Impinger I 1000 Series Service Manual International 85 BLOW UP 1002 1003 S N 4390 ABOVE...
Страница 87: ...Impinger I 1000 Series Service Manual International 87 BLOW UP 1006...
Страница 89: ...Impinger I 1000 Series Service Manual International 89 BLOW UP 1028 1029 1032...
Страница 91: ...Impinger I 1000 Series Service Manual International 91 BLOW UP 1030...
Страница 93: ...Impinger I 1000 Series Service Manual International 93 BLOW UP 1042 1043...
Страница 95: ...Impinger I 1000 Series Service Manual International 95 BLOW UP 1033 1034 1046 1047...
Страница 97: ...Impinger I 1000 Series Service Manual International 97 BLOW UP 1228 1229...
Страница 99: ...Impinger I 1000 Series Service Manual International 99 BLOW UP 1242 1243...
Страница 101: ...Impinger I 1000 Series Service Manual International 101 BLOW UP OVEN BACK GAS...
Страница 103: ...Impinger I 1000 Series Service Manual International 103 BLOW UP OVEN BACK ELECTRIC...
Страница 105: ...Impinger I 1000 Series Service Manual International 105 BLOW UP CONVEYOR MOTOR ASSEMBLY S N 4390 ABOVE...
Страница 107: ...Impinger I 1000 Series Service Manual International 107 BLOW UP SERIES 1000 CONVEYOR...
Страница 109: ...Impinger I 1000 Series Service Manual International 109 BLOW UP SERIES 1200 CONVEYOR CONTROL...
Страница 111: ...Impinger I 1000 Series Service Manual International 111 BLOW UP SERIES 1200 CONVEYOR...
Страница 112: ...Impinger I 1000 Series Service Manual International 112...